Faber HOOD PRIMUS PLUS ENERGY IN HCSC BK 90

Faber HOOD PRIMUS PLUS ENERGY IN HCSC BK 90 Kitchen Chimney User Manual

1. Introduction

This user manual provides detailed instructions for the safe and efficient operation, installation, and maintenance of your new Faber HOOD PRIMUS PLUS ENERGY IN HCSC BK 90 Kitchen Chimney. Please read this manual thoroughly before using the appliance and retain it for future reference.

Faber HOOD PRIMUS PLUS ENERGY IN HCSC BK 90 Kitchen Chimney, front view.

Figure 1: Faber HOOD PRIMUS PLUS ENERGY IN HCSC BK 90 Kitchen Chimney

2. Safety Instructions

  • Ensure the chimney is installed by a qualified technician according to local regulations and this manual.
  • Do not operate the chimney without the filters in place.
  • Regularly clean the filters to prevent grease buildup, which can be a fire hazard.
  • Do not flambé under the range hood.
  • Keep children away from the appliance during operation and cleaning.
  • Disconnect the power supply before any maintenance or cleaning.
  • Ensure adequate ventilation in the room when the range hood is used simultaneously with gas or other fuel-burning appliances.

3. Product Overview

3.1 Components Included

  • 1 x Faber HOOD PRIMUS PLUS ENERGY IN HCSC BK 90 Kitchen Chimney Unit
  • 1 x User Manual
  • Installation Kit (screws, wall plugs, etc. - may vary)

3.2 Technical Specifications

FeatureSpecification
ModelHOOD PRIMUS PLUS ENERGY IN HCSC BK 90
TypeCurved Shape, Wall Mounted
Size90 cm
Suction Power1500 m³/hr
Filter TypeBaffle Filter
Control TypeTouch Control, Gesture Control, Motion Sensor
Number of Speeds3
Noise Level59 dB
Lighting1 LED Lamp, Moodlight
MaterialGlass
Dimensions (LxWxH)48 x 90 x 60 Centimeters
Wattage180 Watts
Voltage220.0 V
Finish TypeGlossy
Diagram showing the dimensions of the Faber 90 cm chimney.

Figure 2: Chimney Dimensions (LxWxH: 48 x 90 x 60 cm)

4. Installation

Proper installation is crucial for the optimal performance and safety of your chimney. It is highly recommended to have the chimney installed by a certified professional. Before installation, ensure you have the correct measurements for your kitchen space.

4.1 Pre-Installation Checks

  • Cabinet Size: Measure the clear width between your kitchen cabinets. Common chimney widths are 60 cm, 75 cm, and 90 cm. Ensure your chosen chimney size fits the available space.
  • Height Clearance: Measure the height from your gas stove to the intended chimney base. Minimum clearance varies by chimney shape:
    • For T-shape / Curved models: 28-30 inches (71-76 cm)
    • For Slant models: 18-22 inches (46-56 cm)
    Always confirm these measurements before purchasing and installation.
  • Ducting: Decide between ducted installation (expelling smoke outside) or ductless use (with a charcoal filter, purchased separately).
Diagram showing options for ducted and ductless chimney installation.

Figure 3: Ducted vs. Ductless Installation Options

4.2 Installation Video Guide

Video 1: This video provides essential guidelines for measuring your kitchen space to ensure proper chimney selection and installation. It covers how to measure the width between cabinets and the height from the gas stove to the chimney base, highlighting minimum clearance requirements for different chimney shapes.

5. Operation

Your Faber chimney is equipped with advanced controls for ease of use.

5.1 Control Panel

The chimney features a user-friendly control panel with Touch Control, Gesture Control, and Motion Sensor capabilities.

Faber Chimney with gesture touch control panel and 1500 m3/hr suction capacity.

Figure 4: Control Panel with Touch and Gesture Controls

  • Touch Control: Directly tap the icons on the panel to adjust settings.
  • Gesture Control: Wave your hand in front of the sensor to turn the chimney On/Off or switch between speeds. This provides a hygienic, touch-free operation.
  • Motion Sensor: Automatically detects motion for convenient operation.

5.2 Speed Settings

The chimney offers 3 speed settings to match your cooking needs, from light simmering to heavy frying.

5.3 Mood Light

Activate the Mood Light feature for ambient lighting in your kitchen. The central LED lamp provides clear illumination of the cooking area. Long press the light button to adjust brightness.

Faber Chimney with soft LED light illuminating the cooking area.

Figure 5: Chimney with Soft LED Light

5.4 Autoclean Alarm

The chimney features an Autoclean Alarm that activates after every 30 hours of usage, reminding you to perform the autoclean cycle for optimal performance and longevity.

5.5 Product Features Overview Video

Video 2: This video highlights key features of the Faber 90 cm Autoclean Chimney, including its powerful suction, smart controls, baffle filter technology, and warranty information.

6. Maintenance and Cleaning

Regular maintenance ensures the efficiency and lifespan of your chimney.

6.1 Baffle Filter Cleaning

The baffle filters are designed to separate grease particles. They should be cleaned regularly, especially when the Autoclean Alarm activates.

  • Remove the baffle filters by sliding them out.
  • Wash the filters with warm soapy water or in a dishwasher.
  • Ensure filters are completely dry before re-installing.
Close-up view of the baffle filters inside the Faber chimney.

Figure 6: Baffle Filters

6.2 Autoclean Function

The Autoclean touch feature initiates a self-cleaning cycle that melts and collects grease in an oil collector. Empty the oil collector periodically.

Icon representing i-clean technology for grease sensing.

Figure 7: i-Clean Technology for Autoclean

6.3 Exterior Cleaning

Wipe the exterior surfaces with a soft, damp cloth and mild detergent. Avoid abrasive cleaners or harsh chemicals.

7. Troubleshooting

If you encounter any issues, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Chimney not turning onNo power supply, loose connectionCheck power outlet, ensure plug is secure.
Low suction powerClogged filters, improper ductingClean baffle filters. Check ducting for obstructions or leaks.
Excessive noiseLoose parts, motor issue, improper installationEnsure all parts are secure. If noise persists, contact customer support.
Lights not workingFaulty LED lamp, wiring issueContact customer support for lamp replacement or wiring inspection.

For issues not listed here or if solutions do not resolve the problem, please contact Faber customer support.

8. Warranty and Support

Your Faber HOOD PRIMUS PLUS ENERGY IN HCSC BK 90 Kitchen Chimney comes with a comprehensive warranty to ensure your peace of mind.

  • Product Warranty: 2 Years Comprehensive Warranty on the product.
  • Motor Warranty: 12 Years Warranty on the motor.
Faber Protect+ logo indicating extended warranty for the product.

Figure 8: Faber Protect+ Extended Warranty

8.1 Customer Support

For installation services, technical assistance, or warranty claims, please contact Faber customer support:

Toll-Free Number: 1800-209-3484

Please have your product model number and purchase details ready when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.