Introduction
This manual provides essential information for the proper setup, operation, and maintenance of your INKBIRD Home Radon Detector, Model INK-RD1-B. This device is designed to continuously monitor indoor radon levels, offering both short-term and long-term average readings to help assess radon exposure in your home or workplace.
Product Overview

The INKBIRD Home Radon Detector, Model INK-RD1-B, is a portable device designed for continuous radon monitoring. It features a clear digital display for easy reading of radon levels.

Detailed view of the detector's components, including the display, battery compartment, and radon sensing area.
Key Features
- Reliable Radon Measurement: Provides three distinct radon averages: long-term (up to 1 year), last-day (updated hourly), and last 7-day.
- Extended Battery Life: Operates for up to 2 years on 3 AAA batteries (included).
- Low Battery Indicator: A visual alert appears on the screen when the battery power is low.
- Flexible Placement: Features a foldable stand for flat surfaces and a hanging hole for wall mounting.
- Optimal Placement: Designed for areas close to the ground, such as basements, cellars, garages, and living rooms.
Setup and Installation
Battery Installation
- Locate the battery compartment on the back of the device.
- Remove the battery cover.
- Insert 3 AAA batteries, ensuring correct polarity.
- Replace the battery cover.

Ensure batteries are installed correctly for proper device function.
Initial Placement
For accurate measurement, the detector should be placed approximately 50 cm (20 inches) from the ground and at least 150 cm (59 inches) from any windows, doors, or vents. It should not be moved during the measurement period.

The detector can be placed on a flat surface using its foldable stand or mounted on a wall using the hanging hole.
First Use and Calibration
Upon initial setup, the device requires a period of 6 to 24 hours before displaying measurement data. During this time, the display may show flashing dashes. The average value for 7 days will appear after the detector has operated for more than 7 days.

The detector needs 6-24 hours to begin displaying radon data.
Operating Instructions
Understanding the Display
The INKBIRD Home Radon Detector displays three types of average radon readings:
- Long-Term Average: Represents the average radon value for the ongoing measurement period, up to a maximum of one year. This value is updated once every 24 hours.
- Short-Term Average: This value alternates between showing the radon level over the last 24 hours and over the last 7 days. It is updated once every 24 hours. The short-term average is useful for observing the immediate effects of actions taken to reduce radon levels, such as increasing ventilation.

Explanation of Long-Term and Short-Term Average readings.
Measurement Indicator
A blinking indicator on the screen confirms that the detector is actively working and taking measurements.
Understanding Radon Levels
Radon is a naturally occurring radioactive gas that can accumulate in homes and is a significant health concern. Understanding the measured levels is crucial for ensuring indoor air quality.

US Radon Gas Standard and Air Quality Categories.
The radon gas standard in the United States is 150 Bq/m3, which is equivalent to approximately 4 pCi/L (1 pCi/L = 37 Bq/m3).
- More than 4 pCi/L (148 Bq/m3): Poor Air Quality. If levels remain above this for more than 1 month, contact a radon professional for assessment and mitigation.
- Between 2.7 – 4 pCi/L (100 - 148 Bq/m3): Fair Air Quality. Continue monitoring. If levels persist for more than 3 months, consider consulting a radon professional.
- Less than 2.7 pCi/L (100 Bq/m3): Good Air Quality. Maintain current conditions.

Radon risk levels across the United States, as per US EPA guidelines.
Maintenance
Battery Replacement
When the low battery prompt appears on the screen, it is time to replace the batteries. Please note that all data will be deleted after restarting the detector.
Important: If the device batteries are removed and immediately replaced, the device may display an "Err" message. To avoid this, leave the device without batteries for at least 15 minutes after removal before reinstalling new batteries. The device should then return to normal operation.

Proper battery replacement procedure to prevent errors.
Troubleshooting
- Issue: Device displays "Err" after battery replacement.
Solution: Remove batteries and wait for 15 minutes before reinserting them. This allows the device to reset properly. - Issue: No immediate radon reading after setup.
Solution: The detector requires 6 to 24 hours to initialize and begin displaying accurate data. This is normal operation.
Specifications
| Product Dimensions | 4.72 x 2.76 x 0.94 inches |
| Item Model Number | INK-RD1-US-BLACK |
| Batteries | 3 AAA batteries required (included) |
| Item Weight | 0.37 Pounds (5.92 ounces) |
| Power Source | Battery Powered |
| Alarm | Visual |
Warranty and Support
The INKBIRD Home Radon Detector typically comes with a 1-year warranty from the date of purchase. For specific warranty details, technical support, or service inquiries, please refer to the contact information provided with your product packaging or visit the official Inkbird website.
Video Resources