This manual provides essential information for the safe and efficient operation of your Kehua Tech KR3000A-RML 3KVA Online 120V Uninterruptible Power Supply (UPS). Please read this manual thoroughly before installation and operation, and retain it for future reference.

The KR3000A-RML is designed to provide reliable power protection for sensitive electronic equipment, ensuring continuous operation during power outages and protecting against power fluctuations.

2. Safety Instructions

Always adhere to the following safety precautions to prevent injury or damage to the UPS and connected equipment.

  • Electrical Safety:
    • Do not open the UPS casing. There are no user-serviceable parts inside. Refer all servicing to qualified service personnel.
    • Ensure the UPS is connected to a grounded AC power outlet.
    • Do not connect non-computer related items, such as medical equipment or life support systems, to the UPS.
    • Disconnect the UPS from the AC power source before performing any maintenance or cleaning.
  • Battery Safety:
    • The UPS contains a Lithium-Ion battery. Do not dispose of the battery in fire, as it may explode.
    • Do not attempt to replace the battery yourself. Battery replacement should only be performed by qualified service personnel.
    • If battery leakage occurs, avoid contact with skin and eyes. Rinse affected areas with plenty of water and seek medical attention.
  • Placement and Environment:
    • Install the UPS in a well-ventilated area, free from excessive dust, humidity, and corrosive substances.
    • Avoid placing the UPS near heat sources or in direct sunlight.
    • Ensure adequate clearance around the UPS for proper airflow.
    • Do not block ventilation openings.

3. Package Contents

Carefully unpack the UPS and check the contents. If any items are missing or damaged, contact your dealer immediately.

  • Kehua Tech KR3000A-RML UPS Unit
  • User Manual (this document)
  • Power Cord(s)
  • USB Communication Cable
  • Rack Mount Kit (if applicable)
  • Tower Stand (if applicable)

4. Product Overview

4.1 Front Panel

Front view of the Kehua Tech KR3000A-RML UPS, showing the LCD display and control buttons.

Figure 4.1: Front view of the KR3000A-RML UPS. This image displays the front panel of the UPS, featuring a prominent LCD screen that shows operational status and input/output voltage. Below the screen are several control buttons for navigating menus and managing UPS functions. The overall design is a sleek black rack-mountable unit with ventilation grilles.

The front panel features an LCD display for real-time status monitoring and control buttons for configuration.

  • LCD Display: Shows input/output voltage, battery level, load percentage, and various alarm messages.
  • Control Buttons: Used to navigate menus, confirm selections, and perform specific operations like self-test or alarm mute.

4.2 Rear Panel

Side view of the Kehua Tech KR3000A-RML UPS in a tower configuration, showing the LCD display.

Figure 4.2: Side view of the KR3000A-RML UPS in tower configuration. This image shows the UPS oriented vertically with optional tower stands. The front panel with its LCD display is visible, emphasizing the unit's compact design when used in a tower setup. The side view highlights the depth and overall form factor of the UPS.

The rear panel provides all necessary connection ports for power input, output, and communication.

  • AC Input: Power cord connection for utility power.
  • Output Receptacles: Seven (7) outlets for connecting protected equipment.
  • Communication Ports: USB, RS-232, and optional SNMP card slot for monitoring and management.
  • EPO (Emergency Power Off) Port: For remote shutdown in emergencies.

5. Setup

5.1 Site Selection

Choose a location that meets the following criteria:

  • Indoors, away from direct sunlight and heat sources.
  • Well-ventilated, with ambient temperature between 0°C and 40°C (32°F and 104°F).
  • Humidity between 20% and 90% (non-condensing).
  • Away from flammable gases, corrosive liquids, and excessive dust.
  • On a stable, flat surface capable of supporting the UPS weight.

5.2 Initial Charging

Before initial use, connect the UPS to a standard AC power outlet for at least 8 hours to ensure the internal Lithium-Ion battery is fully charged. The UPS will charge the battery whether it is turned on or off.

5.3 Connecting Equipment

  1. Ensure the UPS is turned off and disconnected from the AC power source.
  2. Connect your critical equipment (computers, monitors, network devices) to the output receptacles on the rear panel of the UPS. Do not overload the UPS beyond its rated capacity (3000W).
  3. Connect the UPS power cord to a grounded AC power outlet.
  4. (Optional) Connect the USB communication cable from the UPS to your computer for monitoring and graceful shutdown capabilities using compatible UPS management software.

6. Operating the UPS

6.1 Turning On the UPS

Press and hold the power button on the front panel for approximately 3 seconds until you hear a beep and the LCD display illuminates. The UPS will perform a self-test and then enter online mode.

6.2 Turning Off the UPS

To turn off the UPS, press and hold the power button for approximately 3 seconds until the LCD display turns off. If the UPS is connected to AC power, it will continue to charge the battery even when off.

6.3 LCD Display and Indicators

The LCD display provides real-time information about the UPS status. Common indicators include:

  • Input Voltage: Displays the current utility power voltage.
  • Output Voltage: Displays the voltage supplied by the UPS to connected equipment.
  • Battery Level: Shows the remaining battery charge.
  • Load Percentage: Indicates the percentage of the UPS's capacity being used by connected equipment.
  • Operating Mode: Shows if the UPS is in Online, Battery, or Bypass mode.
  • Alarm Indicators: Icons or messages indicating specific warnings or errors (e.g., overload, battery low, fault).

6.4 Self-Test Function

It is recommended to perform a self-test periodically (e.g., once a month) to ensure the battery and internal circuitry are functioning correctly. Refer to the UPS's front panel button guide or management software for initiating a self-test.

7. Maintenance

Proper maintenance ensures the longevity and optimal performance of your UPS.

  • Cleaning: Use a soft, dry cloth to clean the exterior of the UPS. Do not use liquid or aerosol cleaners.
  • Battery Care: The Lithium-Ion battery has an average life of 8 years. To maximize battery life, avoid frequent deep discharges. Keep the UPS connected to AC power to keep the battery charged.
  • Ventilation: Regularly check that the ventilation openings are clear of dust and obstructions.
  • Environmental Conditions: Ensure the UPS operates within the recommended temperature and humidity ranges.

8. Troubleshooting

This section provides solutions to common issues you may encounter with your UPS. If the problem persists, contact technical support.

ProblemPossible CauseSolution
UPS does not turn on.No AC input power; Battery deeply discharged; Power button not held long enough.Check AC power connection and outlet; Allow UPS to charge for several hours; Press and hold power button for 3 seconds.
UPS beeps continuously.Overload; Battery low; Fault condition.Reduce connected load; Allow battery to charge; Check LCD for specific fault code and refer to manual.
UPS is in battery mode frequently.Unstable utility power; Sensitivity setting too high.Check utility power quality; Adjust UPS input voltage sensitivity via software (if available).
Connected equipment not powered.UPS is off; Overload; Faulty outlet.Turn on UPS; Reduce load; Try a different outlet on the UPS.

9. Specifications

FeatureDetail
ModelKR3000A-RML
Capacity3KVA / 3000W
Input Voltage120 Volts
Battery TypeLithium Ion
Battery Life (Avg.)8 Years
Output Outlets7
ColorBlack
ManufacturerKehua Tech
ASINB0BRL6N1YL
First AvailableJanuary 3, 2023

10. Warranty and Support

For warranty information and technical support, please refer to the warranty card included with your product or visit the official Kehua Tech website. Keep your purchase receipt as proof of purchase for warranty claims.

For further assistance, you may contact the seller, Critical Power Warehouse, through the Amazon platform or their direct support channels.

© 2023 Kehua Tech. All rights reserved.

This manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.