ANENG 682 Backlit Color Screen

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

ANENG 682 Multimeter Tester User Manual

Brand: ANENG | Model: 682 Backlit Color Screen

Introduction

The ANENG 682 Multimeter is a sophisticated 6000-count True-RMS auto-ranging digital multimeter designed for accurate and versatile electrical measurements. Featuring a large 5.0-inch color backlit screen, it enhances readability in various lighting conditions. This smart meter automatically identifies measurement content and selects the optimal range, making it suitable for both beginners and experienced professionals. It is capable of measuring AC/DC current, AC/DC voltage, resistance, frequency, duty cycle, capacitance, continuity, diode, temperature, and live/zero wire detection.

ANENG 682 Multimeter main unit with test leads and accessories

Figure 1: ANENG 682 Multimeter and included accessories.

What's in the Box

The ANENG 682 Multimeter package includes the following items:

  • 1x ANENG 682 Multimeter
  • 1x Combination Lead (includes 4x connection sockets, 2x PVC cables, 2x copper needles, 2x U-shaped inserts, 2x meter pens, 2x alligator clips, 2x puncture needles)
  • 1x Multimeter Test Lead
  • 1x Temperature Line (Thermocouple)
  • 1x Type-C Charging Cable
  • 1x Instruction Manual
  • 1x Storage Bag
Contents of the ANENG 682 Multimeter package, including the meter, leads, and charging cable.

Figure 2: All components included with the ANENG 682 Multimeter.

Video 1: Unboxing and overview of the ANENG 682 Multimeter and its accessories.

Initial Setup

Charging the Multimeter

The ANENG 682 Multimeter comes with a built-in rechargeable lithium-ion battery. To charge the device:

  1. Locate the Type-C charging port on the side of the multimeter. It is protected by a rubber cover.
  2. Carefully open the rubber cover to expose the charging port.
  3. Connect the provided Type-C charging cable to the multimeter's port.
  4. Plug the other end of the charging cable into a suitable USB power adapter (not included) or a USB port.
  5. The flashlight port will flash red to indicate that the device is charging. Once fully charged, the light may change or turn off.
ANENG 682 Multimeter connected to a charging cable, showing the charging port.

Figure 3: Connecting the Type-C charging cable to the multimeter.

Video 2: Demonstrating the charging process of the ANENG 682 Multimeter.

Operating Instructions

The ANENG 682 Multimeter features a "Smart Mode" that automatically identifies the measurement type and selects the appropriate range. For specific functions, you can manually switch modes.

Power On/Off

To power on the multimeter, long press the power button located on the left side of the device. The screen will illuminate and display "Auto". To power off, long press the power button again. The device will automatically enter sleep mode if no test instructions are given for a period of time.

DC Voltage Measurement

In Smart Mode, the multimeter can automatically detect and measure DC voltage. Connect the red test lead to the "VΩHz" input jack and the black test lead to the "COM" input jack. Touch the probes to the positive and negative terminals of the DC source (e.g., battery). The display will show the DC voltage reading.

Measuring DC voltage of a battery with the ANENG 682 Multimeter.

Figure 4: Measuring DC voltage of various batteries.

AC Voltage Measurement

In Smart Mode, the multimeter can automatically detect and measure AC voltage. Connect the red test lead to the "VΩHz" input jack and the black test lead to the "COM" input jack. Insert the probes into the AC outlet or connect to the AC source. The display will show the AC voltage and frequency readings.

Measuring AC voltage from a power outlet with the ANENG 682 Multimeter.

Figure 5: Measuring AC voltage from a power strip.

Diode Testing

To measure diodes, press the "SEL" button to cycle through modes until the diode symbol appears on the screen. Connect the red test lead to the "VΩHz" input jack and the black test lead to the "COM" input jack. Align the positive and negative poles of the diode with the respective probes. The display will show the forward voltage drop.

Resistance Measurement

In Smart Mode, the multimeter can automatically detect and measure resistance. Connect the red test lead to the "VΩHz" input jack and the black test lead to the "COM" input jack. Touch the probes to the two ends of the resistor. The display will show the resistance value. There is no need to correspond to positive and negative poles for resistance measurement.

Measuring resistance of a component with the ANENG 682 Multimeter.

Figure 6: Measuring resistance of a component.

Continuity Test

In Smart Mode, the multimeter can automatically detect continuity. Connect the red test lead to the "VΩHz" input jack and the black test lead to the "COM" input jack. Touch the probes to the two points you want to test for continuity. If there is continuity (low resistance), the multimeter will emit an audible buzzer sound.

Non-Contact Voltage (NCV) Detection

The NCV function allows for voltage detection without direct contact. Press the "SEL" button to switch to NCV mode (indicated by "EF" on the screen). Move the top of the multimeter near an AC voltage source. The device will emit an alarm sound and the frequency of the alarm will increase as you get closer to the voltage source, indicating stronger electric field presence.

ANENG 682 Multimeter performing NCV detection with lighting feature.

Figure 7: NCV detection in action, showing the lighting feature for dark areas.

Live Wire Recognition

To identify live (fire) and neutral (zero) wires, switch to "Live" mode using the "SEL" button. Insert the red test lead into the "VΩHz" input jack. Touch the red probe to the wire. A fast alarm frequency indicates a live wire, while no alarm indicates a neutral wire.

ANENG 682 Multimeter detecting a live wire in an electrical outlet.

Figure 8: Using the Live wire recognition feature.

Temperature Measurement

To measure temperature, connect the provided temperature line (thermocouple) to the appropriate input jacks (usually "VΩHz" and "COM" or dedicated temperature ports if available). Press the "SEL" button to switch to temperature mode. Place the thermocouple tip on the object whose temperature you wish to measure. The display will show the temperature in Celsius or Fahrenheit.

Measuring temperature with the ANENG 682 Multimeter using a thermocouple.

Figure 9: Temperature measurement using the thermocouple.

Frequency Measurement

In Smart Mode, the multimeter can measure frequency. Connect the red test lead to the "VΩHz" input jack and the black test lead to the "COM" input jack. Apply the probes to the circuit where you want to measure frequency. The display will show the frequency in Hz.

Capacitance Measurement

To measure capacitance, press the "SEL" button to switch to capacitance mode. Important: Before measuring, ensure the capacitor is fully discharged by short-circuiting its terminals to avoid damage to the multimeter. Connect the red test lead to the "VΩHz" input jack and the black test lead to the "COM" input jack. Touch the probes to the capacitor terminals. The display will show the capacitance value.

Measuring capacitance of a capacitor with the ANENG 682 Multimeter.

Figure 10: Measuring capacitance of various capacitors.

Current Measurement (AC/DC)

To measure current, you must insert the red test lead into the appropriate current input hole ("mA A" for milliamperes/amperes or "10A/10SEC MAX" for higher currents) and the black test lead into the "COM" input jack. Press the "SEL" button to select AC or DC current measurement. Connect the multimeter in series with the circuit you wish to measure. The display will show the current reading.

Measuring AC current in a circuit with the ANENG 682 Multimeter.

Figure 11: Measuring AC current in a lighting circuit.

Measuring DC current from a battery to an LED strip with the ANENG 682 Multimeter.

Figure 12: Measuring DC current from a battery to an LED strip.

Video 3: Comprehensive demonstration of various measurement functions including voltage, resistance, continuity, NCV, temperature, frequency, capacitance, and current.

Maintenance

  • Cleaning: Use a soft, damp cloth to clean the multimeter's surface. Do not use abrasive cleaners or solvents.
  • Storage: Store the multimeter in its provided storage bag in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: To prolong battery life, charge the multimeter regularly, even if not in frequent use. Avoid fully discharging the battery for extended periods.
  • Test Leads: Inspect test leads for any damage (cracks, frayed wires) before each use. Replace damaged leads immediately to ensure safety and accurate readings.

Troubleshooting

ProblemPossible CauseSolution
Multimeter does not power on.Low battery or fully discharged battery.Charge the multimeter using the provided Type-C cable.
Inaccurate readings.Damaged test leads, incorrect mode selection, or external interference.Check test leads for damage and replace if necessary. Ensure correct measurement mode is selected. Avoid strong electromagnetic fields.
"OL" (Overload) displayed.Measurement range exceeded or open circuit.Ensure the measurement is within the device's specified range. Check for open circuits in continuity or resistance tests.
No NCV detection.Not in NCV mode or voltage is too low.Switch to NCV mode. Ensure the voltage source is active and strong enough for detection.
Screen is dim or unreadable.Low battery or poor lighting conditions.Charge the battery. Utilize the built-in backlight feature by pressing the appropriate button.

Technical Specifications

FeatureSpecification
Product Dimensions3.94 x 3.94 x 0.79 inches
Item Weight0.6 Grams (0.02 ounces)
Model Numberb9086ca8-3c6c-489d-80f9-acde8eab414b
Batteries1 Lithium Ion battery (included)
ManufacturerANENG
Country of OriginChina
Power SourceBattery Powered
Style682 Backlit Color Screen
ColorMulticolor
Display5.0-inch Color Backlit LCD
Counts6000 Counts
True-RMSYes
Auto-RangingYes (Smart Mode)

Warranty and Support

ANENG provides dedicated service and technical support for its products. For any inquiries, technical assistance, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ANENG store online. The product is designed for durability and precision, featuring built-in explosion-proof ceramic fuse tube, reverse polarity protection, low battery indicator, and overload protection across all ranges.

You can visit the official ANENG Store for more information and support: ANENG Official Store

© 2025 ANENG. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.