1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Anderic RH-786R Ceiling Fan Remote Receiver. This receiver is designed as a direct replacement for specific Casablanca Hunter ceiling fan models, ensuring seamless integration and restoration of functionality. Please read this manual thoroughly before installation to ensure proper setup and safe operation.
2. Product Overview
The Anderic RH-786R is a high-quality replacement receiver for DC motor ceiling fans. It is engineered to provide reliable control over your fan's speed and light functions when paired with a compatible remote transmitter.



3. Compatibility
The Anderic RH-786R receiver is specifically designed to replace Casablanca Hunter Ceiling Fan Receiver Part#: G105301000. It is compatible with the following Casablanca ceiling fan models with DC motors:
3.1. Compatible Casablanca Models:
- Fellini DC 59518
- Stealth
- Rhine 165M DC motor
3.2. Specific Series Compatibility:
- CASABLANCA Holliston DC series
- CASABLANCA Panama DC series
- CASABLANCA Stealth DC series
3.3. Legacy (pre-2013) DC Motor Fans (model numbers ending in "B"):
- Panama DC: C66U11B, C66U45B, C66U546B
- Holliston DC: C31U11B, C31U45B, C31U546B
- Stealth DC: C45G11B, C45G45B, C45G695B
3.4. New Platform (2013+) DC Motor Fans (model numbers starting with "5"):
- Panama DC: 59510, 59511, 59512
- Fellini DC: 59518
- Stealth DC: 59105, 59106, 59107
- Stealth DC LED: 59164, 59165
Important Note: This receiver is designed to work with your existing compatible transmitter (e.g., RR787T). The receiver is sold separately and does not include the handheld remote control transmitter. While some users have reported success with other brands, the manufacturer specifies compatibility primarily with the listed Casablanca models. Ensure compatibility with your specific Casablanca Hunter ceiling fan model before installation.
4. Setup and Installation
Installation of the Anderic RH-786R receiver requires basic electrical knowledge. If you are unsure about any steps, it is recommended to consult a qualified electrician.
4.1. Safety Precautions:
- ALWAYS TURN OFF POWER at the circuit breaker or fuse box before beginning installation.
- Ensure the fan is securely mounted and all existing wiring is in good condition.
- Do not exceed the maximum wattage ratings for the fan and light.
4.2. Installation Steps:
- Disconnect Power: Locate the circuit breaker controlling the ceiling fan and turn it off. Verify power is off by attempting to operate the fan or light.
- Access Fan Canopy: Carefully lower the fan canopy (the cover that attaches to the ceiling) to expose the wiring connections.
- Remove Old Receiver (if applicable): Disconnect the wiring from the old receiver, noting the color codes and connections. It is often helpful to take a picture before disconnecting.
- Connect New Receiver: Connect the wires from the Anderic RH-786R receiver to the corresponding wires in the ceiling fan and house wiring. Refer to the wiring diagram provided with your original fan or the receiver's label for specific connections. Typical connections include:
- Black (Live/Hot)
- White (Neutral)
- Blue (Light)
- Red (Fan)
- Green/Bare Copper (Ground)
- Position Receiver: Carefully tuck the new receiver into the fan canopy, ensuring it does not pinch any wires. The compact design of the RH-786R facilitates easy placement.
- Secure Canopy: Reattach the fan canopy to the ceiling bracket.
- Restore Power: Turn the power back on at the circuit breaker.
- Test Functionality: Use your compatible remote transmitter to test the fan speeds and light operation.
5. Operation
Once installed, the Anderic RH-786R receiver operates in conjunction with your existing compatible remote control. The functionality will mirror that of the original receiver, allowing control over fan speed and light settings.
5.1. Pairing (if necessary):
In most cases, if replacing an identical receiver, pairing may not be required. However, if the remote does not respond after installation, follow the pairing instructions specific to your Casablanca remote control (e.g., pressing a 'Learn' button on the receiver or a specific button sequence on the remote within a set timeframe after restoring power).
5.2. Basic Functions:
- Fan Speed Control: Adjust fan speed (e.g., low, medium, high) using the designated buttons on your remote.
- Light Control: Turn the light on/off or dim/brighten (if supported by your remote and fan) using the light control buttons.
- Reverse Function: If your fan supports reverse operation via remote, use the corresponding button on your remote.
6. Maintenance
The Anderic RH-786R receiver is designed for long-lasting functionality and requires minimal maintenance.
- Cleaning: Ensure the receiver area within the fan canopy remains free of dust and debris. Periodically, with power off, gently wipe the exterior of the receiver if accessible.
- Connections: If experiencing intermittent issues, ensure all wiring connections are secure and free from corrosion. Always turn off power before checking connections.
- Environmental Conditions: Avoid exposing the receiver to excessive moisture or extreme temperatures, as this can affect its performance and lifespan.
7. Troubleshooting
If you encounter issues with your Anderic RH-786R receiver, refer to the following troubleshooting guide:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fan/Light not responding to remote | No power to receiver Remote not paired Faulty remote batteries Incorrect wiring | Check circuit breaker. Ensure all wiring connections are secure. Replace remote batteries. Perform pairing procedure (refer to remote manual). Verify wiring against diagram. |
| Fan operates, but light does not | Light bulb faulty Light wire connection loose Light wattage exceeded | Replace light bulb. Check blue wire connection to light. Ensure total light wattage does not exceed 310 Watts. |
| Fan operates at only one speed | Incorrect wiring Remote issue | Verify fan speed wiring. Test with a known good remote if possible. |
| Intermittent operation | Loose wiring connection Interference | Turn off power and re-secure all wire nuts. Ensure receiver is not obstructed by metal or other electronic devices. |
8. Specifications
| Feature | Specification |
|---|---|
| Model Number | RH-786R |
| Product Dimensions | 10 x 2 x 2.7 inches |
| Item Weight | 4.8 ounces |
| Manufacturer | Anderic |
| Compatible Devices | Ceiling Fan (DC Motor) |
| Connectivity Technology | Infrared (IR) |
| Max Light Wattage | 310 Watts Max |
9. Warranty and Support
Anderic products are manufactured with high-quality materials to ensure durability and long-lasting functionality. For specific warranty information or technical support, please refer to the official Anderic website or contact their customer service directly. Keep your purchase receipt for warranty claims.
Manufacturer: Anderic
Website: Visit the Anderic Store on Amazon