1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the MYPIN FH4-4CRNB Digital Counter. Please read this manual thoroughly before using the device to ensure correct operation and to prevent damage.
2. Safety Information
Always observe the following safety precautions:
- Ensure the power supply voltage matches the device's specifications (90-260V AC/DC).
- Disconnect power before making any wiring connections or performing maintenance.
- Installation and wiring should be performed by qualified personnel.
- Do not operate the device in environments with excessive moisture, dust, or corrosive gases.
- Avoid exposing the device to strong vibrations or impacts.
- Do not disassemble or modify the device; this will void the warranty.
3. Product Overview
The MYPIN FH4-4CRNB is a versatile digital counter designed for industrial applications. It features a clear display, multiple preset functions, and relay output for control. Its compact 48x48mm size makes it suitable for various panel installations.

Figure 3.1: Front and side view of the MYPIN FH4-4CRNB Digital Counter, showing the display, control buttons, and a simplified wiring diagram on the side label.
4. Specifications
| Feature | Specification |
|---|---|
| Model | FH4-4CRNB |
| Input Type | Switch / Encoder |
| Output Type | Relay Output (10kHz) |
| Power Supply | 90-260V AC/DC |
| Accuracy | ±0.1% P.S |
| Dimensions | 48mm x 48mm |
| Preset Capability | 4 Presets |
5. Installation and Mounting
The FH4-4CRNB counter is designed for panel mounting. Follow these steps for proper installation:
- Cut a panel cutout of 45mm x 45mm (approx.) in the desired mounting location.
- Insert the counter into the cutout from the front.
- Secure the counter using the provided mounting brackets from the rear of the panel.
- Ensure adequate ventilation around the device to prevent overheating.

Figure 5.1: Rear view of the MYPIN FH4-4CRNB Digital Counter, showing ventilation slots for proper heat dissipation.
6. Wiring Diagram
Refer to the following diagrams for correct wiring connections. Always ensure power is disconnected before wiring.

Figure 6.1: Detailed view of the terminal block on the MYPIN FH4-4CRNB Digital Counter.

Figure 6.2: Wiring diagram as shown on the side label of the MYPIN FH4-4CRNB Digital Counter.
Terminal Connections:
- Terminals 1 & 2 (NC, NO): Relay Output 1 (Normally Closed, Normally Open)
- Terminals 3 & 4 (NC, NO): Relay Output 2 (Normally Closed, Normally Open)
- Terminals 5 & 6 (NC, NO): Relay Output 3 (Normally Closed, Normally Open)
- Terminals 7 & 8 (NC, NO): Relay Output 4 (Normally Closed, Normally Open)
- Terminals 9 & 10 (90-260V): AC/DC Power Input (90-260V)
- Terminal 11 (RST): Reset Input
- Terminal 12 (24V): 24V DC Auxiliary Power Output (for sensors, etc.)
- Terminal INA: Input A (for counting signal)
- Terminal INB: Input B (for counting signal, direction, or phase)
- Terminal GND: Ground for inputs
Note: The specific function of INA and INB may vary based on the selected counting mode (e.g., single input, quadrature input). Refer to the device's on-screen menu for mode configuration.
7. Operation
After successful wiring and power-up, the counter will display the current count. The front panel typically includes buttons for setting parameters and controlling the count.
Basic Functions:
- Counting: The device counts pulses received on the input terminals (INA/INB).
- Preset Setting: Use the front panel buttons to navigate menus and set up to 4 preset values. When the count reaches a preset value, the corresponding relay output will activate.
- Reset: The count can be reset manually via a front panel button or externally via the RST input terminal.
- Mode Selection: The counter supports various counting modes (e.g., up/down counting, batch counting, frequency measurement). These modes are typically configured through the device's internal menu system.
Detailed instructions for menu navigation and parameter setting are usually provided in the device's on-screen interface or a separate programming guide.
8. Maintenance
The MYPIN FH4-4CRNB Digital Counter requires minimal maintenance. Follow these guidelines to ensure longevity:
- Cleaning: Gently wipe the display and casing with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Inspection: Periodically check wiring connections for tightness and signs of wear or corrosion.
- Environment: Ensure the operating environment remains within specified temperature and humidity ranges.
9. Troubleshooting
If you encounter issues with your digital counter, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | No power supply or incorrect voltage. | Check power connections and ensure voltage is within 90-260V AC/DC. |
| Counter not counting. | Incorrect input wiring, faulty sensor, or incorrect counting mode. | Verify input wiring (INA, INB, GND). Test the sensor. Check counting mode settings in the menu. |
| Relay output not activating. | Preset value not reached, incorrect output wiring, or faulty relay. | Confirm the count has reached the preset. Check relay output wiring. Test the relay if possible. |
| Display shows error code. | Internal error or parameter setting issue. | Refer to the device's specific error code list (if available) or try resetting the device to factory defaults. |