Master-Bilt 19-14783-BMG

Master-Bilt 19-14783-BMG Sollatek Temp Control FCA-23 Instruction Manual

Model: 19-14783-BMG | Brand: Master-Bilt

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Master-Bilt 19-14783-BMG Sollatek Temp Control FCA-23. This component is a genuine Original Equipment Manufacturer (OEM) replacement part designed for Master-Bilt refrigeration systems.

Using genuine OEM parts ensures:

2. Safety Information

WARNING: Before attempting any installation, maintenance, or troubleshooting, ensure the power supply to the refrigeration unit is disconnected. Failure to do so can result in serious injury or death.

3. What's in the Box

Master-Bilt 19-14783-BMG Sollatek Temp Control FCA-23, front view

Figure 1: Overall view of the Master-Bilt 19-14783-BMG Sollatek Temp Control FCA-23. This image shows the main body of the control unit with its integrated wiring and a small adjustment knob.

4. Setup and Installation

The Master-Bilt 19-14783-BMG is a direct OEM replacement part. Installation procedures will vary depending on the specific Master-Bilt refrigeration unit it is being installed into. Always refer to the service manual for your specific refrigeration model for detailed installation instructions.

  1. Power Disconnection: Ensure the refrigeration unit is completely disconnected from its power source.
  2. Access: Gain access to the existing temperature control unit within the refrigeration system. This may involve removing panels or covers.
  3. Wiring Disconnection: Carefully label and disconnect all wires from the old temperature control. Note the position of each wire (e.g., Neutral, Live In, Common, Aux1, Aux2, Probe connections).
  4. Removal: Unmount the old temperature control unit.
  5. New Unit Placement: Mount the new Master-Bilt 19-14783-BMG unit in the same location.
  6. Wiring Connection: Reconnect the wires to the new unit according to the labels made in step 3 and the wiring diagram provided on the unit itself or in your refrigeration unit's service manual.
  7. Probe Installation: Ensure temperature probes (PRB 1, PRB 2) are correctly installed and positioned within the refrigeration unit as per the original setup.
  8. Secure Connections: Verify all electrical connections are secure and properly insulated.
  9. Reassembly: Reinstall any removed panels or covers.
  10. Power Restoration: Restore power to the refrigeration unit and test for proper operation.
Master-Bilt 19-14783-BMG Sollatek Temp Control FCA-23, side view with wiring terminals

Figure 2: Side view of the control unit, highlighting the "Neutral," "Live In," "Common," "Aux1," and "Aux2" wiring terminals. This view is crucial for correct electrical connections.

Master-Bilt 19-14783-BMG Sollatek Temp Control FCA-23, side view with dial and probe connections

Figure 3: Another side view showing the temperature adjustment dial (numbered 1-9 and OFF) and the probe connections (PRB 1, PRB 2), along with D-SW (Defrost Switch) and other indicators.

5. Operating Instructions

The Sollatek Temp Control FCA-23 regulates the temperature within your Master-Bilt refrigeration unit. Operation typically involves setting the desired temperature and monitoring the unit's performance.

Master-Bilt 19-14783-BMG Sollatek Temp Control FCA-23, top view with label and settings

Figure 4: Top view of the control unit, showing the product label with model information and a detailed table of settings and functions, including LED indicators and switch configurations. This table provides critical operational details.

6. Maintenance

The Master-Bilt 19-14783-BMG Sollatek Temp Control FCA-23 is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure its longevity and proper function.

7. Troubleshooting

If your refrigeration unit is not maintaining temperature or exhibiting unusual behavior, consider the following basic troubleshooting steps. For complex issues, contact a qualified service technician.

ProblemPossible CauseSolution
Unit not coolingPower supply issue, incorrect temperature setting, faulty probe, compressor malfunction.Check power, verify temperature setting, inspect probe connections, consult service manual for compressor diagnostics.
Temperature fluctuates widelyLoose probe connection, faulty probe, control unit malfunction, poor insulation.Secure probe, replace faulty probe, inspect unit for damage, check refrigeration unit's insulation.
Control unit indicator lights not workingNo power to the unit, internal fault.Verify power supply, check wiring connections. If power is present and wiring is correct, the unit may require replacement.

8. Specifications

FeatureDetail
Model Number19-14783-BMG
ManufacturerMaster-Bilt
Part TypeSollatek Temp Control FCA-23 (Genuine OEM Replacement Part)
Product Dimensions5.8 x 4.6 x 2.4 inches
Item Weight1 Pound
ASINB0BQSS4X75

9. Warranty and Support

As a genuine Master-Bilt OEM part, this product is covered by Master-Bilt's standard warranty for replacement parts. Please refer to your original equipment documentation or contact Master-Bilt customer service for specific warranty terms and conditions.

For technical support, service, or to inquire about other genuine Master-Bilt parts, please contact Master-Bilt directly or an authorized Master-Bilt service provider. Always provide the model number (19-14783-BMG) and the serial number of your refrigeration unit when seeking support.