1. Introduction
This manual provides essential information for the safe and efficient operation of your Rohde & Schwarz RTB2002 EDU Digital Oscilloscope. The RTB2002 EDU is a two-channel, 70 MHz digital oscilloscope designed for educational and professional environments, featuring a 10-bit A/D converter and a 10.1-inch capacitive touchscreen. This EDU bundle includes the RTB-PK1 application package, expanding its capabilities with various triggering and decoding options, history memory, frequency response analysis, and an arbitrary waveform generator.

Figure 1: Front view of the Rohde & Schwarz RTB2002 EDU Digital Oscilloscope. This image shows the front panel of the oscilloscope, featuring a large capacitive touchscreen displaying a sine wave. Control knobs and buttons for vertical, horizontal, and trigger adjustments are visible on the right side. Input channels (Ch1, Ch2, Ch3, Ch4) are located at the bottom right, while auxiliary outputs and USB ports are on the bottom left.
2. What's in the Box
Verify that all items listed below are present in your package:
- Rohde & Schwarz RTB2002 Digital Oscilloscope (serialized product)
- RTB-PK1 Application Bundle (pre-installed or with activation key)
- Power Cord
- Standard Probes (quantity may vary)
- Calibration Certificate
- Quick Start Guide
3. Initial Setup
- Unpacking: Carefully remove the oscilloscope and all accessories from the packaging. Retain the original packaging for future transport or storage.
- Power Connection: Connect the provided power cord to the oscilloscope's power input and then to a grounded AC power outlet.
- Power On: Press the power button, typically located on the front or side panel, to turn on the device. Allow the oscilloscope to complete its self-test and boot-up sequence.
- Probe Connection: Connect the oscilloscope probes to the desired input channels (e.g., Ch1, Ch2) on the front panel. Ensure a secure connection.
- Probe Compensation: Perform probe compensation as described in the operating section to ensure accurate measurements.
4. Operating Instructions
4.1 Basic Controls
- Vertical Controls: Use the dedicated knobs for each channel (Ch1, Ch2) to adjust vertical position and voltage scale (V/div).
- Horizontal Controls: Adjust the horizontal position and time base (s/div) using the horizontal control knob.
- Trigger Controls: Set the trigger level, source, and mode using the trigger section controls to stabilize waveforms.
- Touchscreen Interface: The 10.1-inch capacitive touchscreen allows for intuitive gesture-based control, including pinch-to-zoom and drag-to-pan.
4.2 Application Bundle (RTB-PK1)
The RTB-PK1 application bundle enhances the oscilloscope's functionality:
- R&S®RTB-K1: I²C/SPI triggering and decoding for serial bus analysis.
- R&S®RTB-K2: UART/RS232 triggering and decoding.
- R&S®RTB-K3: CAN/LIN triggering and decoding (if enabled).
- R&S®RTB-K15: History & Segmented Memory for capturing and analyzing long signal sequences.
- R&S®RTB-K36: Frequency Response Analysis (Bode Plot) for characterizing passive components and circuits.
- R&S®RTB-B6: Arbitrary Waveform Generator for creating custom test signals.
Access these functions via the instrument's menu system, typically through dedicated function buttons or the touchscreen interface.
5. Maintenance
5.1 Cleaning
- Disconnect the power cord before cleaning.
- Use a soft, damp cloth with mild detergent to clean the exterior surfaces. Avoid abrasive cleaners or solvents.
- For the touchscreen, use a lint-free cloth specifically designed for electronic displays.
5.2 Storage
Store the oscilloscope in a clean, dry environment within the specified operating temperature range. If storing for extended periods, use the original packaging to protect against dust and physical damage.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No power | Power cord disconnected; Power outlet fault | Check power cord connection; Test power outlet; Check power button |
| No waveform displayed | Probe not connected; Incorrect trigger settings; Signal too small/large | Connect probe to signal source; Adjust trigger level/mode; Adjust V/div and s/div settings |
| Unstable waveform | Incorrect trigger source/level; No signal present | Verify trigger source and adjust trigger level; Ensure signal is connected |
7. Specifications
| Feature | Specification |
|---|---|
| Model Number | RTB2002 EDU |
| Channels | Two Channel |
| Bandwidth | 70 MHz |
| A/D Converter | 10-bit |
| Vertical Sensitivity | 1 mV/div (full measurement bandwidth) |
| Display | 10.1" High-resolution Capacitive Touchscreen |
| Product Dimensions | 1 x 1 x 1 inches |
| Weight | 6 Pounds |
| Manufacturer | ROHDE & SCHWARZ USA INC. |
| Date First Available | April 14, 2025 |
8. Warranty and Support
For detailed warranty information, please refer to the warranty card included with your product or visit the official Rohde & Schwarz website. For technical support, service, or additional documentation, please contact Rohde & Schwarz customer service directly. Contact information can typically be found on the manufacturer's website or in the quick start guide.