Görbach TD25CP

Görbach TD25 Thermostatic Shower Column Instruction Manual

1. Introduction

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your Görbach TD25 Thermostatic Shower Column. Please read this manual carefully before installation and use to ensure proper function and safety. Keep this manual for future reference.

2. Safety Information

  • Ensure all water connections are properly sealed to prevent leaks.
  • The thermostatic mixer is designed to maintain a constant water temperature. The 38°C safety stop helps prevent scalding, especially for children and the elderly.
  • Do not attempt to disassemble or repair the unit yourself. Contact qualified personnel for assistance.
  • Ensure the hot and cold water inlets are connected correctly as indicated in the installation section. Incorrect connection can lead to malfunction or safety hazards.

3. Package Contents

Verify that all components are present before beginning installation:

  • 1 x Stainless Steel Shower Column
  • 1 x ABS Hand Shower
  • 1 x ABS Hand Shower Holder
  • 1 x Stainless Steel Shower Head (25cm diameter)
  • 1 x Brass Thermostatic Faucet
  • 1 x 150 cm Hand Shower Hose
  • Mounting Accessories
  • Instruction Manual
Görbach TD25 Shower Column Components

Figure 1: Overview of the main components of the Görbach TD25 shower column, including the shower bar, rain shower head, hand shower, and thermostatic mixer.

4. Setup and Installation

Follow these steps for proper installation of your shower column:

  1. Prepare the Installation Area: Ensure the wall surface is clean and suitable for mounting. The distance between the wall and the center of the shower head should be 39.5 to 44.5 cm.
  2. Connect the Thermostatic Mixer: Connect the hot and cold water lines to the thermostatic mixer. The standard distance between the hot and cold water inlets is 15 ± 1 cm. Ensure hot water is connected to the left inlet (marked 'H' or red) and cold water to the right inlet (marked 'C' or blue). Incorrect connection will prevent the thermostatic function from working correctly.
Görbach TD25 Thermostatic Mixer Hot and Cold Water Connection

Figure 2: Diagram illustrating the correct connection of hot and cold water lines to the thermostatic mixer, emphasizing the importance of correct orientation.

  1. Assemble the Shower Column: The upper shower column must be inserted into the lower shower column to a depth of 5 to 7 cm to prevent water leakage. The upper column has a diameter of 20 mm, and the lower column has a diameter of 24 mm.
  2. Mount the Shower Column: The shower column can be adjusted in height from 74 to 114 cm. The upper wall bracket has an adjustable height range of 66 to 105 cm, making it universally applicable for existing holes and small spaces. This adjustable bracket allows for installation, disassembly, transformation, and renovation without causing cracks or holes in tiles or walls.
  3. Install Shower Head and Hand Shower: Attach the 25cm round rain shower head. It can rotate ±30° and 360° for optimal positioning. Connect the 150 cm shower hose to the hand shower and the thermostatic mixer. The hand shower holder is height-adjustable and can rotate 360°.
Görbach TD25 Shower Column Installation Dimensions

Figure 3: Detailed installation diagram with key dimensions for mounting the shower column, including adjustable wall bracket and recommended distances.

Görbach TD25 Adjustable Shower Column Features

Figure 4: This diagram shows the adjustable features of the shower column, including the height-adjustable bar, rotatable upper bar, and adjustable shower head angle.

5. Operating Instructions

5.1 Thermostatic Mixer Operation

The thermostatic mixer allows you to set and maintain a desired water temperature. The temperature adjustment range is 20°C to 53°C.

  • Temperature Control: Rotate the temperature knob to adjust the water temperature.
  • 38°C Safety Stop: The mixer includes a safety button at 38°C. To exceed this temperature, press and hold the safety button while rotating the knob. This prevents accidental scalding.
Görbach TD25 Thermostatic Mixer with 38°C safety stop

Figure 5: Detail of the thermostatic mixer, highlighting the 38°C safety button to prevent scalding and ensure a consistent water temperature.

5.2 Water Flow Control and Diverter

The diverter allows you to switch between the overhead rain shower and the hand shower.

  • Flow Control: Use the other knob on the mixer to turn the water flow on/off and adjust its intensity.
  • Switching Shower Modes: The brass diverter allows you to easily switch between the fixed shower head and the hand shower. Press the button to toggle between the two outputs.
Görbach TD25 Shower Diverter Function

Figure 6: A diagram demonstrating how to switch water flow between the overhead rain shower and the hand shower using the integrated diverter button.

5.3 Rain Shower Head

The 25cm round rain shower head provides a wide and even water distribution. It features anti-limescale silicone nozzles for easy cleaning and resistance to obstruction. The shower head can be rotated and tilted to your preferred angle.

Görbach TD25 Shower Column with wide rain shower spray

Figure 7: This image illustrates the wide coverage of the 25cm rain shower head, providing an immersive shower experience.

6. Maintenance

Regular cleaning and maintenance will ensure the longevity and optimal performance of your Görbach TD25 Shower Column.

  • Cleaning the Surface: Clean the chrome surfaces with a soft cloth and mild soap or a non-abrasive bathroom cleaner. Avoid harsh chemicals, abrasive sponges, or cleaners containing alcohol, ammonia, or bleach, as these can damage the finish.
  • Cleaning Shower Head Nozzles: The rain shower head and hand shower feature anti-limescale silicone nozzles. To remove limescale buildup, gently rub the nozzles with your fingers or a soft brush. For stubborn deposits, use a descaling solution specifically designed for bathroom fixtures, following the product instructions.
  • Hose Maintenance: Periodically check the shower hose for any signs of wear or damage. Ensure it is not kinked during use or storage.

7. Troubleshooting

If you encounter any issues with your shower column, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Water temperature is inconsistent or not reaching desired setting.Incorrect hot/cold water connection; thermostatic cartridge issue; insufficient water pressure.Verify hot and cold water connections are correct. Check water pressure. If problem persists, contact support.
Low water pressure from shower heads.Limescale buildup in nozzles; clogged filter in mixer; low household water pressure.Clean shower head nozzles. Check and clean filters in the thermostatic mixer. Consult a plumber if household water pressure is consistently low.
Water leakage from connections.Loose connections; damaged seals/washers; improper assembly of shower column sections.Tighten all connections. Replace any damaged seals or washers. Ensure the upper and lower shower column sections are inserted correctly (5-7 cm depth).
Diverter not switching properly.Internal mechanism obstruction or wear.Ensure no debris is obstructing the diverter button. If it remains stuck or faulty, contact support.

8. Specifications

FeatureDetail
BrandGörbach
Model NumberTD25CP
ColorChrome
MaterialStainless Steel, Brass, ABS (Acrylonitrile Butadiene Styrene)
Number of Handles1
Handle MaterialBrass
Mounting TypeWall Mount
Flow Rate Description15 lpm (liters per minute)
Shower Head Size25 cm
Maximum Pressure10 Bar
Adjustable Column Height74-114 cm
Adjustable Upper Wall Mount Height66-105 cm
Thermostat Temperature Range20-53 °C (with 38°C safety stop)

9. Warranty and Support

For warranty information or technical support, please refer to the documentation provided with your purchase or contact Görbach customer service. Keep your proof of purchase for warranty claims.