VisionTechShop DSW-100

VisionTechShop DSW-100 Portion Food Scale User Manual

Model: DSW-100

Introduction

This manual provides comprehensive instructions for the safe and efficient operation, setup, and maintenance of your VisionTechShop DSW-100 Portion Food Scale. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage.

The DSW-100 is a high-precision digital portion control scale designed for commercial and industrial use. It features a dual LCD display, a durable stainless steel platter, and is switchable between multiple units (Lb/Oz/Kg/g). This model is NTEP Approved Legal for Trade (COC #22-007) and NSF Certified, ensuring accuracy and hygiene standards.

VisionTechShop DSW-100 Portion Food Scale with dual display

Image: The VisionTechShop DSW-100 Portion Food Scale, showcasing its dual LCD display and stainless steel platter.

Setup

1. Unpacking and Inspection

Carefully remove all components from the packaging. Verify that all items listed below are present and undamaged:

If any items are missing or damaged, please contact VisionTechShop customer support immediately.

2. Platter Installation

Place the stainless steel platter securely on top of the scale's weighing platform. Ensure it sits flat and does not wobble.

DSW-100 scale with stainless steel platter

Image: The DSW-100 scale with its stainless steel removable platter correctly installed.

3. Powering the Scale

The DSW-100 scale can be powered using the included AC adapter or 4 D-cell alkaline batteries (not included).

DSW-100 scale with power adapter

Image: The DSW-100 scale showing the power adapter connection point.

4. Initial Power-On

Press the ON/OFF button to turn on the scale. The display will perform a self-test and then show "0.000 lb" (or the last used unit) when ready for weighing.

Video: An introductory video showcasing the features and components of the VisionTechShop DSW-100 Portion Food Scale, including initial power-on.

Operating Instructions

1. Turning On/Off

2. Unit Switching

The DSW-100 supports multiple weighing units: pounds (Lb), ounces (Oz), kilograms (Kg), and grams (g).

3. Tare Function

The Tare function allows you to subtract the weight of a container or packaging, so only the net weight of the item is displayed.

4. Zero Function

The Zero function allows you to reset the display to zero if there is a slight weight on the platter or if the display drifts from zero.

5. Backlight and Power Saving Settings

The DSW-100 features an LCD display with backlight and an auto power-off function to conserve energy. These settings can be adjusted.

Video: This video demonstrates how to adjust the backlight and power saving settings on the DSW-100 scale.

To access and change these settings:

  1. Turn on the scale.
  2. Press and hold the ZERO button, then press the UNIT button three times. The display will show "SPC 00".
  3. Press the ZERO button to enter the setting mode. The display will show "0011".
  4. The four digits represent different settings (from right to left):
    • Bit 0 (Rightmost digit): Automatic shutdown time setting (0: No automatic shutdown, 1: Allows automatic shutdown).
    • Bit 1: Allow automatic entry into power saving mode (0: Allow, 1: Forbid).
    • Bit 3 / Bit 2 (Leftmost two digits): Backlight auto-off time setting (00: 10 seconds, 01: 20 seconds, 10: 30 seconds, 11: Do not close).
  5. Use the UNIT button to input '0' and the TARE button to input '1' for each digit, starting from the rightmost digit.
  6. For example, to change the automatic shutdown setting to no automatic shutdown (Bit 0 = 0), you would press UNIT, UNIT, TARE, UNIT in order to achieve "0010".
  7. Continuously press the ZERO button until you return to the normal weighing mode to save the settings.

Maintenance

1. Cleaning

The stainless steel platter is removable for easy cleaning. Use a soft, damp cloth with mild soap to clean the platter and the scale body. Avoid abrasive cleaners or harsh chemicals that could damage the finish or electronic components. Ensure the scale is completely dry before re-use.

2. Battery Replacement

If the scale is battery-powered and the display indicates low battery, replace the 4 D-cell alkaline batteries. Ensure the scale is turned off before opening the battery compartment and observe correct polarity when inserting new batteries.

3. General Care

Troubleshooting

ProblemPossible CauseSolution
Scale does not turn onNo power, dead batteries, or faulty AC adapter.Check AC adapter connection. If using batteries, replace with new D-cell batteries. Ensure power switch is in the ON position.
Inaccurate readingsScale not level, overloaded, or unstable surface.Place the scale on a flat, stable, and level surface. Ensure no objects are touching the platter or scale. Do not exceed maximum capacity.
Display shows "OVER"Scale is overloaded.Remove excess weight immediately. Do not exceed the scale's maximum capacity.
Display shows "UNST"Unstable weighing conditions.Ensure the scale is on a stable surface and free from vibrations or air currents.
Backlight not workingBacklight auto-off setting is too short or disabled.Refer to the "Backlight and Power Saving Settings" section in Operating Instructions to adjust the backlight auto-off time.

Specifications

FeatureDetail
ModelDSW-100
BrandVisionTechShop
Capacity6lb x 0.002lb (96oz x 0.05oz, 3kg x 0.001kg, 3000g x 1g)
Readability0.002 pounds / 1 gram
Display TypeDual LCD with Backlight
Platter MaterialStainless Steel
Platter Dimensions9.06 x 7.72 inches (W x D)
Product Dimensions9.45 x 11.22 x 4.41 inches (W x D x H) / 240 x 285 x 112mm
Item Weight3.51lb / 1.6kg (Net Weight)
Power SourceAC Adapter (included) or 4 x D-cell Alkaline Batteries (not included)
Battery LifeApprox. 1000 hours (without backlight)
CertificationsNTEP Approved Legal for Trade (COC #22-007), NSF Certified
FeaturesAutomatic Zero Tracking, Initial Zero Setting Mechanism, Semi-Automatic Zero (Push Button), Semi-Automatic Tare (Push Button), Auto Power-Off Function, Soft Touch Tact Switch
NTEP Certificate of Conformance for DSW-100 scale

Image: NTEP Certificate of Conformance for the DSW-100 scale, verifying its legal for trade status.

Related Documents - DSW-100

Preview VisionTech DSW-100 Digital Scale Owner's Manual
This manual provides detailed information on the VisionTech DSW-100 digital scale, including product specifications, basic operations, settings, and troubleshooting.
Preview GL-6000L Scale Calibration Instructions - VisionTechShop
Step-by-step guide for calibrating the VisionTechShop GL-6000L portable bench scale. Includes instructions for various weight capacities.
Preview VTS-CS4 LCD High Resolution Digital Crane Scale Calibration Manual
Detailed calibration manual for the VTS-CS4 LCD High Resolution Digital Crane Scale, covering scale capacity settings and calibration procedures using both panel buttons and a remote controller.
Preview VLP-100B Firmware Update Instructions
Step-by-step guide on how to update the firmware for the VLP-100B label printing scale using a USB stick.
Preview S41SBU / S41PBU Cash Drawer Quick Start Guide
A quick start guide for the S41SBU and S41PBU cash drawers, detailing cable installation, coin partition adjustment, disassembly, and lock functions.