TIMEMORE TMBMBP

TIMEMORE Black Mirror Basic Pro Coffee Scale User Manual

1. Introduction

Thank you for purchasing the TIMEMORE Black Mirror Basic Pro Coffee Scale. This digital scale is designed for precise coffee brewing, offering accurate weight measurement, an integrated timer, and a unique flow rate display. Please read this manual carefully before use to ensure proper operation and maintenance.

TIMEMORE Black Mirror Basic Pro Coffee Scale in white and black colors

Image: The TIMEMORE Black Mirror Basic Pro Coffee Scale, available in both white and black finishes, showcasing its sleek, minimalist design.

2. Package Contents

  • TIMEMORE Black Mirror Basic Pro Coffee Scale (Main Unit) x1
  • Silicone Mat x1
  • Type-C USB Charging Cable x1
  • Instruction Manual x1

3. Product Features

  • Flow Rate Measurement Function: Simultaneously measures pouring amount and pouring time, allowing direct monitoring of pouring speed for consistent coffee quality.
  • Simple and Stylish Design: Features a square shape with a matte finish for enhanced slip resistance. Includes a silicone mat for additional grip and water protection.
  • USB Charging: Equipped with a Type-C USB charging interface. The 1600mAh lithium battery provides approximately 10 hours of use on a single full charge. A Type-C charging cable is included.
  • Timer Function: Integrated timer for precise control over brewing duration, essential for both pour-over and espresso extraction.
  • Hidden LED Screen Design: The LED display appears with a light touch. The scale automatically powers off after 180 seconds of inactivity, or after 15 minutes if the timer is active.

4. Setup

  1. Unpack: Carefully remove all components from the packaging.
  2. Initial Charge: Before first use, fully charge the scale using the provided Type-C USB cable and a 5V 1A-2A adapter. Do not use the scale while it is charging.
  3. Place Silicone Mat: Position the silicone mat on the weighing platform to protect the surface and prevent items from slipping.
  4. Placement: Place the scale on a flat, stable surface to ensure accurate readings.

5. Operating Instructions

5.1 Power On/Off

  • Power On: Lightly touch the power button (U) to turn on the scale. The hidden LED display will illuminate.
  • Power Off: Press and hold the power button (U) for 3 seconds to turn off the scale. The scale will automatically power off after 180 seconds of inactivity (15 minutes if the timer is running).

5.2 Tare Function

  • Place an empty container on the weighing platform.
  • Press the tare button (T) to reset the display to zero. You can now add ingredients, and only their weight will be measured.

5.3 Timer Function

  • Press the timer button (O) to start the timer.
  • Press the timer button (O) again to pause/resume the timer.
  • Press and hold the timer button (O) for 3 seconds to reset the timer to zero.

5.4 Flow Rate Measurement

  • When the scale is in weighing mode and the timer is active, the display will show the current flow rate (grams per second).
  • This feature allows you to monitor and adjust your pouring speed during brewing.

Video: An overview demonstrating the TIMEMORE Black Mirror Basic Pro Coffee Scale's features, including its timer and flow rate measurement capabilities during coffee brewing.

6. Charging

  • Connect the provided Type-C USB cable to the scale's charging port and to a 5V 1A-2A USB power adapter (not included).
  • The battery indicator on the display will show charging status.
  • A full charge takes approximately 10 hours of continuous use.
  • Important: Do not use the scale while it is charging.

7. Maintenance

  • Cleaning: Wipe the scale surface with a soft, damp cloth. Do not use abrasive cleaners or immerse the scale in water.
  • Storage: Store the scale in a dry place, away from direct sunlight and extreme temperatures.
  • Protection: Always use the silicone mat to protect the weighing platform from spills and scratches.

8. Troubleshooting

  • Scale does not turn on:
    • Ensure the scale is fully charged. Connect it to a power source and allow it to charge for several hours.
    • Try pressing and holding the power button for a longer duration (5-10 seconds).
  • Inaccurate readings:
    • Ensure the scale is on a flat, stable surface.
    • Avoid placing the scale near strong electromagnetic fields or vibrating equipment.
    • Make sure the silicone mat is properly seated and not interfering with the weighing platform.
    • Perform a tare operation before weighing.
  • Display shows "Lo": This indicates low battery. Recharge the scale.
  • Display shows "Err": This indicates an overload. Remove items from the platform immediately to prevent damage.

9. Specifications

BrandTIMEMORE
Model NumberTMBMBP
Dimensions152mm x 130mm x 26mm
Item Weight380 Grams
Measurement Range0.5g - 2000g
Readout Accuracy0.1 Grams
Display TypeLED
Battery Capacity1600mAh Lithium Battery
Power SourceType-C USB Charging
Auto-Off180 seconds (15 minutes with timer active)
Country of OriginChina