Always operate the generator in a well-ventilated area to prevent carbon monoxide poisoning. Never use indoors or in enclosed spaces. Keep children and pets away from the generator during operation. Ensure the generator is placed on a level surface.
Handle fuel with extreme care. Gasoline is highly flammable. Always turn off the engine and allow it to cool before refueling. Do not smoke or use open flames near the generator. Store fuel in approved containers in a well-ventilated area away from ignition sources.
This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
Product Overview
The Pulsar G1200SG is a compact and portable gas-powered generator designed to provide reliable power for various applications. It features a 2-stroke engine, delivering 1,200 peak watts and 900 running watts, making it suitable for camping, tailgating, and light-duty tasks. Its lightweight design and integrated carrying handle ensure easy transport.



Setup
Fuel Filling
- Ensure the generator is on a level surface and the engine is off and cool.
- Unscrew the fuel cap.
- Carefully pour fresh, unleaded gasoline into the fuel tank. The tank capacity is 1.1 gallons.
- Do not overfill. Leave some space for fuel expansion.
- Securely replace the fuel cap.

Oil Filling
- Locate the oil fill cap/dipstick.
- Unscrew and remove the dipstick.
- Add the recommended 2-stroke engine oil (refer to your specific manual for oil type and quantity).
- Use the dipstick to check the oil level, ensuring it is between the upper and lower marks.
- Replace and tighten the dipstick.
General Fuel and Oil Filling Guide (External Video)
The following video provides a general guide on fuel and engine oil filling for generators. Please note that this video is for a different brand (Lifan) and serves as a general reference. Always consult your Pulsar G1200SG owner's manual for specific instructions and recommended oil types.
Operating Instructions
Starting the Generator
- Ensure the generator is on a stable, level surface outdoors and away from any flammable materials.
- Turn the fuel switch to the "ON" position.
- Move the choke lever to the "CHOKE" position (for cold starts).
- Firmly pull the recoil starter handle until the engine starts.
- Once the engine starts, gradually move the choke lever to the "RUN" position.
- Allow the engine to warm up for a few minutes before connecting electrical devices.

Connecting Electrical Devices
- Plug your 120V AC devices into the two AC 120V outlets.
- For battery charging, connect your device to the DC 12V outlet. Note: This outlet is for battery charging only.
- Monitor the indicator light on the control panel. A green light typically indicates normal operation.
- If an overload occurs, the AC Reset or DC Reset button may pop out. Disconnect devices, press the reset button, and restart if necessary.


Stopping the Generator
- Disconnect all electrical devices from the generator.
- Turn the fuel switch to the "OFF" position.
- Allow the engine to run until it runs out of fuel (this helps prevent carburetor issues).
- Once the engine stops, turn the engine switch to the "OFF" position.
General Generator Starting Guide (External Video)
The following video provides a general guide on starting a generator. Please note that this video is for a different brand (Lifan) and serves as a general reference. Always consult your Pulsar G1200SG owner's manual for specific instructions.
Maintenance
Regular maintenance is crucial for the longevity and safe operation of your Pulsar G1200SG generator. Always ensure the engine is off and cool before performing any maintenance.
Spark Plug Maintenance
- Remove the spark plug cap.
- Use a spark plug wrench to remove the spark plug.
- Inspect the spark plug for wear, carbon buildup, or damage. Clean or replace as necessary.
- Ensure the spark plug gap is correct (refer to your manual for specifications).
- Reinstall the spark plug and cap.
Air Filter Cleaning
- Locate and open the air filter cover.
- Remove the air filter element.
- Clean the element with warm, soapy water, rinse thoroughly, and allow it to dry completely. Alternatively, replace with a new filter if heavily soiled or damaged.
- Reinstall the clean/new air filter element and close the cover.
Spark Arrestor Cleaning
- Locate the spark arrestor on the muffler.
- Remove the screws or clamps securing the spark arrestor.
- Carefully remove the spark arrestor screen.
- Clean any carbon deposits from the screen using a wire brush.
- Reinstall the clean spark arrestor screen and secure it with screws/clamps.
General Maintenance Guide (External Video)
The following video provides a general guide on generator maintenance, including spark plug, air filter, and spark arrestor cleaning. Please note that this video is for a different brand (Lifan) and serves as a general reference. Always consult your Pulsar G1200SG owner's manual for specific instructions.
Troubleshooting
If your Pulsar G1200SG generator encounters issues, refer to the following common troubleshooting steps. For more detailed information, always consult your complete owner's manual.
- Engine Not Starting:
- Check fuel level and ensure the fuel valve is ON.
- Ensure the engine switch is ON.
- Check the spark plug for fouling or damage.
- Ensure the choke is in the correct position for starting.
- No Power Output:
- Check if the AC Reset or DC Reset buttons have tripped.
- Ensure connected devices are not exceeding the generator's running wattage (900W).
- Verify all connections are secure.
- Engine Runs Poorly:
- Check the air filter for clogging.
- Inspect the spark plug.
- Ensure fresh fuel is being used.
Specifications
| Feature | Specification |
|---|---|
| Brand | Pulsar |
| Model | PG1202SA |
| Wattage (Peak) | 1200 Watts |
| Wattage (Running) | 900 Watts |
| Fuel Type | Gasoline |
| Power Source | Gas-powered |
| Item Weight | 37.5 Pounds |
| Voltage | 120 Volts |
| Engine Type | 2 Stroke |
| Engine Displacement | 69 Cubic Centimeters |
| Tank Volume | 1.1 Gallons |
| Product Dimensions (L x W x H) | 14"L x 14.8"W x 16.2"H |
| Total Power Outlets | 2 x AC 120V, 1 x DC 12V |
| Special Feature | Portable |
Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided in your Pulsar G1200SG owner's manual or visit the official Pulsar website. Keep your purchase receipt for warranty claims.