Important Safety Information

Always operate the generator in a well-ventilated area to prevent carbon monoxide poisoning. Never use indoors or in enclosed spaces. Keep children and pets away from the generator during operation. Ensure the generator is placed on a level surface.

Handle fuel with extreme care. Gasoline is highly flammable. Always turn off the engine and allow it to cool before refueling. Do not smoke or use open flames near the generator. Store fuel in approved containers in a well-ventilated area away from ignition sources.

This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

Product Overview

The Pulsar G1200SG is a compact and portable gas-powered generator designed to provide reliable power for various applications. It features a 2-stroke engine, delivering 1,200 peak watts and 900 running watts, making it suitable for camping, tailgating, and light-duty tasks. Its lightweight design and integrated carrying handle ensure easy transport.

Pulsar G1200SG 1,200W Gas-Powered Portable Generator
Image: The Pulsar G1200SG 1,200W Gas-Powered Portable Generator, showcasing its compact design and top-mounted carrying handle.
Pulsar G1200SG Control Panel Diagram
Image: A detailed diagram of the Pulsar G1200SG control panel, highlighting the AC 120V outlets, DC 12V battery charging outlet, AC Reset, DC Reset buttons, and the indicator light.
Pulsar G1200SG Generator Dimensions
Image: The Pulsar G1200SG generator with its dimensions labeled: 14 inches long, 14.8 inches wide, and 16.2 inches high, emphasizing its compact size.

Setup

Fuel Filling

  1. Ensure the generator is on a level surface and the engine is off and cool.
  2. Unscrew the fuel cap.
  3. Carefully pour fresh, unleaded gasoline into the fuel tank. The tank capacity is 1.1 gallons.
  4. Do not overfill. Leave some space for fuel expansion.
  5. Securely replace the fuel cap.
Man filling fuel into Pulsar G1200SG generator
Image: A person carefully pouring gasoline into the fuel tank of the Pulsar G1200SG portable generator.

Oil Filling

  1. Locate the oil fill cap/dipstick.
  2. Unscrew and remove the dipstick.
  3. Add the recommended 2-stroke engine oil (refer to your specific manual for oil type and quantity).
  4. Use the dipstick to check the oil level, ensuring it is between the upper and lower marks.
  5. Replace and tighten the dipstick.

General Fuel and Oil Filling Guide (External Video)

The following video provides a general guide on fuel and engine oil filling for generators. Please note that this video is for a different brand (Lifan) and serves as a general reference. Always consult your Pulsar G1200SG owner's manual for specific instructions and recommended oil types.

Video: A general guide on how to fill fuel and engine oil in a generator. This video is from LIFAN POWER and is not specific to the Pulsar G1200SG model.

Operating Instructions

Starting the Generator

  1. Ensure the generator is on a stable, level surface outdoors and away from any flammable materials.
  2. Turn the fuel switch to the "ON" position.
  3. Move the choke lever to the "CHOKE" position (for cold starts).
  4. Firmly pull the recoil starter handle until the engine starts.
  5. Once the engine starts, gradually move the choke lever to the "RUN" position.
  6. Allow the engine to warm up for a few minutes before connecting electrical devices.
Man pulling the recoil starter cord of a Pulsar G1200SG generator
Image: A person pulling the recoil starter cord to start the Pulsar G1200SG generator.

Connecting Electrical Devices

  1. Plug your 120V AC devices into the two AC 120V outlets.
  2. For battery charging, connect your device to the DC 12V outlet. Note: This outlet is for battery charging only.
  3. Monitor the indicator light on the control panel. A green light typically indicates normal operation.
  4. If an overload occurs, the AC Reset or DC Reset button may pop out. Disconnect devices, press the reset button, and restart if necessary.
Man operating Pulsar G1200SG generator on a table
Image: A person operating the Pulsar G1200SG generator, which is placed on a table, with an electrical cord connected.
Pulsar G1200SG generator powering devices at a campsite
Image: The Pulsar G1200SG generator in use at a campsite, providing power to various devices via extension cords.

Stopping the Generator

  1. Disconnect all electrical devices from the generator.
  2. Turn the fuel switch to the "OFF" position.
  3. Allow the engine to run until it runs out of fuel (this helps prevent carburetor issues).
  4. Once the engine stops, turn the engine switch to the "OFF" position.

General Generator Starting Guide (External Video)

The following video provides a general guide on starting a generator. Please note that this video is for a different brand (Lifan) and serves as a general reference. Always consult your Pulsar G1200SG owner's manual for specific instructions.

Video: A general guide on how to start a generator. This video is from LIFAN POWER and is not specific to the Pulsar G1200SG model.

Maintenance

Regular maintenance is crucial for the longevity and safe operation of your Pulsar G1200SG generator. Always ensure the engine is off and cool before performing any maintenance.

Spark Plug Maintenance

  1. Remove the spark plug cap.
  2. Use a spark plug wrench to remove the spark plug.
  3. Inspect the spark plug for wear, carbon buildup, or damage. Clean or replace as necessary.
  4. Ensure the spark plug gap is correct (refer to your manual for specifications).
  5. Reinstall the spark plug and cap.

Air Filter Cleaning

  1. Locate and open the air filter cover.
  2. Remove the air filter element.
  3. Clean the element with warm, soapy water, rinse thoroughly, and allow it to dry completely. Alternatively, replace with a new filter if heavily soiled or damaged.
  4. Reinstall the clean/new air filter element and close the cover.

Spark Arrestor Cleaning

  1. Locate the spark arrestor on the muffler.
  2. Remove the screws or clamps securing the spark arrestor.
  3. Carefully remove the spark arrestor screen.
  4. Clean any carbon deposits from the screen using a wire brush.
  5. Reinstall the clean spark arrestor screen and secure it with screws/clamps.

General Maintenance Guide (External Video)

The following video provides a general guide on generator maintenance, including spark plug, air filter, and spark arrestor cleaning. Please note that this video is for a different brand (Lifan) and serves as a general reference. Always consult your Pulsar G1200SG owner's manual for specific instructions.

Video: A general guide on generator maintenance, including spark plug, air filter, and spark arrestor cleaning. This video is from LIFAN POWER and is not specific to the Pulsar G1200SG model.

Troubleshooting

If your Pulsar G1200SG generator encounters issues, refer to the following common troubleshooting steps. For more detailed information, always consult your complete owner's manual.

  • Engine Not Starting:
    • Check fuel level and ensure the fuel valve is ON.
    • Ensure the engine switch is ON.
    • Check the spark plug for fouling or damage.
    • Ensure the choke is in the correct position for starting.
  • No Power Output:
    • Check if the AC Reset or DC Reset buttons have tripped.
    • Ensure connected devices are not exceeding the generator's running wattage (900W).
    • Verify all connections are secure.
  • Engine Runs Poorly:
    • Check the air filter for clogging.
    • Inspect the spark plug.
    • Ensure fresh fuel is being used.

Specifications

FeatureSpecification
BrandPulsar
ModelPG1202SA
Wattage (Peak)1200 Watts
Wattage (Running)900 Watts
Fuel TypeGasoline
Power SourceGas-powered
Item Weight37.5 Pounds
Voltage120 Volts
Engine Type2 Stroke
Engine Displacement69 Cubic Centimeters
Tank Volume1.1 Gallons
Product Dimensions (L x W x H)14"L x 14.8"W x 16.2"H
Total Power Outlets2 x AC 120V, 1 x DC 12V
Special FeaturePortable

Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact details provided in your Pulsar G1200SG owner's manual or visit the official Pulsar website. Keep your purchase receipt for warranty claims.

Related Documents - PG1202SA

Preview Pulsar G1200SG 1200 Watt 2-Cycle Generator Operator's Manual
This operator's manual provides comprehensive guidance for the Pulsar G1200SG 1200 Watt 2-Cycle portable generator, covering safety, assembly, operation, maintenance, and troubleshooting.
Preview Pulsar PG2200R Portable Generator Operator's Manual
Comprehensive operator's manual for the Pulsar PG2200R portable generator, covering safety, assembly, operation, maintenance, and troubleshooting. Learn how to safely and effectively use your 2200W generator.
Preview Pulsar PG2300iSCO Inverter Gasoline Generator Operator's Manual
Comprehensive operator's manual for the Pulsar PG2300iSCO Inverter Gasoline Generator. This guide covers essential information including safety rules, product features, assembly instructions, detailed operation procedures, maintenance schedules, troubleshooting tips, and a wiring diagram for safe and effective use of the generator.
Preview Pulsar PG2200BiS Inverter Gasoline Generator Operator's Manual
Comprehensive operator's manual for the Pulsar PG2200BiS portable inverter gasoline generator, covering safety, operation, maintenance, and troubleshooting to ensure reliable performance.
Preview Pulsar PG2000iS/PG2300iS Portable Inverter Generator Operator's Manual
This operator's manual provides essential information for the safe operation, assembly, maintenance, and troubleshooting of the Pulsar PG2000iS and PG2300iS portable inverter gasoline generators. Learn how to use your generator effectively and safely.
Preview Pulsar PG13000BRCO Generator Operator's Manual
Comprehensive operator's manual for the Pulsar PG13000BRCO portable generator, covering safe operation, assembly, maintenance, and troubleshooting.