1. Introduction
This user manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your Riester e-Scope Otoscope. Please read this manual thoroughly before using the device and retain it for future reference.

Figure 1: Riester e-Scope Otoscope (Model 2111-203)
2. Safety Information
Always adhere to the following safety guidelines to ensure proper operation and prevent injury or damage to the device:
- Use the otoscope only for its intended purpose of ear examination.
- Do not attempt to disassemble or modify the device. Refer all servicing to qualified personnel.
- Ensure batteries are inserted correctly according to polarity markings.
- Keep the device out of reach of children.
- Avoid direct eye exposure to the LED light.
- Clean and disinfect reusable specula before and after each use as per medical guidelines.
- Store the device in its protective case when not in use to prevent damage.
3. Product Components and Package Contents
3.1. Product Components

Figure 2: Key Components of the e-Scope Otoscope
- 3.7V LED Light Source: Provides bright, clear illumination for examination.
- Fiber Optics: Ensures an unimpeded, free view of the examination area.
- 3x Magnifying Pivoting Lens: Offers triple magnification for detailed viewing and can be pivoted for access.
- Ear Speculum Receptacle: For attaching reusable or disposable ear specula.
- Pneumatic Test Connection: Allows for pneumatic testing (connector and insufflator not included).
- On/Off Switch: Activates and deactivates the LED light.
- Battery Compartment and Casing: Houses the AA batteries and provides a durable ABS synthetic material casing.
3.2. Package Contents
Your Riester e-Scope Otoscope package should contain the following items:
- Riester e-Scope Otoscope (Model 2111-203)
- AA Battery Handle (batteries not included)
- 10 Reusable Ear Specula (5 x 2.5 mm, 5 x 4.0 mm)
- Protective Case
- User Manual
4. Setup
4.1. Battery Installation
The Riester e-Scope Otoscope requires two (2) AA batteries (not included) for operation.
- Unscrew the bottom cap of the battery handle (Component 7 in Figure 2).
- Insert two AA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Screw the bottom cap back on securely.

Figure 3: Battery Installation
4.2. Attaching Ear Specula
Select the appropriate size of ear speculum (2.5 mm for children, 4.0 mm for adults) for the examination.
- Gently push the desired ear speculum onto the speculum receptacle (Component 4 in Figure 2) until it clicks into place.
- To remove, gently pull the speculum straight off.

Figure 4: Attaching an Ear Speculum
5. Operating Instructions
5.1. Powering On/Off
To turn the otoscope on, slide the On/Off switch (Component 6 in Figure 2) upwards. To turn it off, slide the switch downwards.
5.2. Performing an Examination
- Ensure a clean speculum is attached.
- Turn on the otoscope light.
- Gently insert the speculum into the ear canal.
- Look through the viewing lens (Component 3 in Figure 2) to observe the ear canal and tympanic membrane.
- The 3x magnifying lens can be pivoted to either side for an optimal view and to facilitate instrument insertion if needed.
- After examination, turn off the otoscope and remove the speculum.

Figure 5: Proper Use of the Otoscope
5.3. Pneumatic Testing (Optional)
The e-Scope Otoscope is suitable for performance of pneumatic tests. This requires a separate connector and insufflator, which are not supplied with this product. Connect the insufflator to the pneumatic test connection (Component 5 in Figure 2) as per the insufflator's instructions.
6. Maintenance and Care
6.1. Cleaning and Disinfection
- Reusable Specula: Clean and disinfect reusable ear specula thoroughly before and after each use according to standard medical sterilization procedures.
- Otoscope Head and Handle: Wipe the exterior of the otoscope head and handle with a soft cloth dampened with a mild disinfectant solution. Do not immerse the device in liquid.
- Lens: Gently clean the magnifying lens with a lens cleaning cloth or cotton swab moistened with lens cleaner. Avoid abrasive materials.
6.2. Battery Replacement
Replace batteries when the light intensity diminishes. Follow the steps in Section 4.1 for battery installation.
6.3. Storage
Store the otoscope in its provided protective case in a cool, dry place, away from direct sunlight and extreme temperatures, when not in use.
7. Troubleshooting
If you encounter issues with your Riester e-Scope Otoscope, refer to the table below:
| Problem | Possible Cause | Solution |
|---|---|---|
| No light or dim light | Dead or low batteries Incorrect battery polarity Loose connection | Replace batteries Check battery orientation Ensure handle is securely screwed to the head |
| Blurry or unclear view | Dirty lens or speculum Improper focus (if applicable) | Clean the lens and speculum Adjust viewing angle |
| Speculum does not attach securely | Incorrect speculum size Damaged speculum or receptacle | Ensure correct speculum size is used Inspect speculum and receptacle for damage; replace if necessary |
If the problem persists after attempting these solutions, please contact Riester customer support.
8. Specifications
| Feature | Detail |
|---|---|
| Model Number | 2111-203 |
| Light Source | 3.7V LED (Fiber Optic) |
| Magnification | 3x (pivoting lens) |
| Power Supply | 2 x AA Batteries (not included) |
| Dimensions (Package) | 9.57 x 3.58 x 2.2 inches |
| Weight (Package) | 11.75 ounces |
| Country of Origin | Germany |

Figure 6: LED Illumination Benefits
9. Warranty and Support
Riester products are known for their German engineering and commitment to quality. For information regarding warranty coverage, service, or technical support, please refer to the warranty card included with your product or visit the official Riester website. You may also contact Riester customer service directly for assistance.
Riester Customer Service: Please refer to the contact information provided on the product packaging or the official Riester website for the most up-to-date support details.