ASHATA ASHATAm2pax4ives

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

ASHATA Wireless Caregiver Pager System

Model: ASHATAm2pax4ives

1. Introduction

This manual provides detailed instructions for the ASHATA Wireless Caregiver Pager System. This system is designed to provide a reliable and easy-to-use communication solution for patients, the elderly, pregnant women, and children who may require assistance at home. It eliminates the need for shouting and ensures timely attention.

Package Contents:

  • 1 x Receiver (Pager)
  • 1 x Call Button (Transmitter)
  • 1 x Lanyard for Call Button
  • 1 x User Manual
ASHATA Wireless Caregiver Pager System package contents including receiver, call button, lanyard, and manual.

Image 1.1: Package contents of the ASHATA Wireless Caregiver Pager System.

2. Key Features

  • IP55 Waterproof Call Button: The call button is rated IP55 waterproof, making it suitable for use in bathrooms or other areas where it might be exposed to splashes.
  • Adjustable Melodies and Volume: The receiver offers 38 selectable melodies and 4 adjustable volume levels, allowing customization to suit individual preferences and environments.
  • Wide Application: Ideal for patients, the elderly, pregnant women, and children requiring assistance at home, providing a discreet and effective way to call for help.
  • Portable and Convenient: The compact and lightweight design of the call button, along with the included lanyard, makes it easy to carry or wear, ensuring help is always within reach.
  • Powerful Signal Range: The system boasts a signal reception range of up to 330 meters (1082 feet) in open spaces, with the ability for the signal to penetrate walls, ensuring reliable communication throughout your home.
Diagram illustrating the features of the ASHATA Wireless Caregiver Pager System: 1082ft range, IP55 waterproof, 4 adjustable volume levels, alert system, and 38 songs.

Image 2.1: Overview of the system's key features.

Close-up of the call button with water splashing on it, indicating its IP55 waterproof rating.

Image 2.2: The call button is IP55 waterproof.

3. Setup Instructions

3.1. Receiver Installation

  1. Unpack the receiver unit.
  2. Plug the receiver into a standard electrical outlet in a central location within your home. Ensure it is within range of where the call button will be used.
  3. The receiver will power on automatically.
Side view of the ASHATA Wireless Caregiver Pager receiver, showing the electrical prongs and volume/melody buttons.

Image 3.1: Side view of the receiver unit with plug.

3.2. Call Button Preparation

  1. Unpack the call button and the lanyard.
  2. Attach the lanyard to the designated loop on the call button.
  3. The call button comes with a pre-installed battery.
Close-up of the ASHATA Wireless Caregiver Pager call button with its attached blue lanyard.

Image 3.2: Call button with lanyard attached.

3.3. Pairing (If Necessary)

The system is typically pre-paired at the factory for 1-to-1 operation. If you need to re-pair or add additional call buttons/receivers, follow these steps:

  1. Plug in the receiver.
  2. Press and hold the volume button on the receiver for 3-5 seconds until the receiver emits a 'ding' sound and its indicator light flashes. This indicates it is in pairing mode.
  3. Immediately press the call button. The receiver will sound the selected melody, confirming successful pairing.
  4. Repeat for any additional call buttons.

4. Operating Instructions

4.1. Making a Call

To call for assistance, simply press the large 'CALL' button on the transmitter. The receiver will immediately sound the selected melody or alarm siren.

A person in bed, with the ASHATA Wireless Caregiver Pager receiver and call button shown in the foreground, illustrating the 'Nurse Alert System' concept.

Image 4.1: The system in use, showing a patient in bed and the call button and receiver.

4.2. Adjusting Melody and Volume

  1. Melody Selection: Press the 'Melody' button (usually indicated by a music note icon) on the side of the receiver to cycle through the 38 available melodies.
  2. Volume Adjustment: Press the 'Volume' button (usually indicated by a speaker icon) on the side of the receiver to cycle through the 4 volume levels.
The ASHATA Wireless Caregiver Pager receiver and call button, with a nurse attending to a patient in the background, demonstrating the system's purpose.

Image 4.2: Receiver and call button, ready for use.

4.3. Video Demonstration

Video 4.3.1: This video demonstrates the functionality of a similar caregiver call button and pager system, showing how to press the button and how the pager alerts the caregiver. It highlights the ease of use for both the patient and the caregiver.

Video 4.3.2: This video provides a general overview of a wireless caregiver pager, showcasing its components and basic operation for calling assistance.

5. Maintenance

5.1. Cleaning

Wipe the receiver and call button with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the call button is dry after any exposure to water to maintain its IP55 rating.

5.2. Battery Replacement (Call Button)

The call button uses a standard coin cell battery (e.g., CR2032). When the button's indicator light no longer flashes or the signal range decreases significantly, it's time to replace the battery.

  1. Carefully open the back cover of the call button using a small screwdriver or coin.
  2. Remove the old battery and insert a new CR2032 battery, ensuring correct polarity (+/-).
  3. Securely close the back cover.

6. Troubleshooting

ProblemPossible CauseSolution
Receiver does not sound when button is pressed.Out of range, low call button battery, receiver unplugged, or not paired.Move closer to the receiver, replace call button battery, ensure receiver is plugged in, or re-pair the devices (see Section 3.3).
Receiver sounds continuously or unexpectedly.Call button stuck or interference.Check if the call button is pressed. Move receiver away from other electronic devices.
Short signal range.Obstructions (thick walls), interference, or low call button battery.Relocate receiver to a more central position, avoid placing near large metal objects, or replace call button battery.

7. Specifications

FeatureDetail
BrandASHATA
Model NumberASHATAm2pax4ives
Control MethodTouch
Mounting TypeFloor Mount (Receiver is plug-in)
Sensor TechnologyWireless
Waterproof RatingIP55 (Call Button)
Melodies38 selectable songs
Volume Levels4 adjustable levels
Wireless RangeUp to 330 meters (1082 feet) in open space
Power Source (Receiver)AC Plug (US Plug)
Power Source (Call Button)Battery (CR2032, included)
Package Dimensions10.2 x 8.2 x 6.8 cm; 140 g
Voltage240 Volts (Receiver)

8. Warranty and Support

For warranty information or technical support, please refer to the contact details provided with your purchase or visit the ASHATA official website. Keep your purchase receipt for warranty claims.

© 2024 ASHATA. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.