1. Introduction
Thank you for choosing Sinocare AQ Pro I Blood Glucose Test Strips and Lancets. This manual provides essential information for the proper use, maintenance, and storage of these components to ensure accurate and reliable blood glucose monitoring. These test strips and lancets are designed for use exclusively with the Sinocare AQ Pro I Blood Glucose Meter.
Important Note: Do not mix these strips with other glucometer models.

Image: Compatibility chart for Sinocare glucometers, highlighting that AQ Pro I strips are only compatible with the AQ Pro I meter.
2. Setup
2.1 Unpacking and Inspection
Upon receiving your Sinocare AQ Pro I Test Strips and Lancets, carefully open the packaging and inspect the contents. Ensure all items are present and undamaged. The package includes 50 blood glucose test strips and 50 sterile lancets.

Image: The complete package of Sinocare AQ Pro I Blood Glucose Test Strips and Lancets, showing two vials of strips and a box of lancets.
2.2 Preparing the Test Strip Vial
The test strips are stored in a vial to protect them from moisture. Ensure the cap is tightly closed after removing a strip. Note the expiration date printed on the vial and packaging. All strips are recently produced to ensure fresh expiration dates.
2.3 Preparing the Lancet
Each lancet is sterile and for single use only. Twist off the protective cap of a new lancet before inserting it into a lancing device (not included in this package, typically comes with the glucometer).
3. Operating Instructions
Follow these steps for accurate blood glucose testing using your Sinocare AQ Pro I Blood Glucose Meter (sold separately) with these test strips and lancets:
- Wash and Dry Hands: Thoroughly wash your hands with soap and warm water, then dry them completely. This helps prevent contamination and improves blood flow.
- Prepare Lancing Device: Insert a new sterile lancet into your lancing device according to its instructions. Set the penetration depth.
- Insert Test Strip: Remove one test strip from the vial and immediately close the cap tightly. Insert the test strip into the test strip port of your Sinocare AQ Pro I Blood Glucose Meter. The meter will turn on automatically.
- Obtain Blood Sample: Prick the side of your fingertip with the lancing device. Gently squeeze your finger to form a small drop of blood.
- Apply Blood Sample: Touch the tip of the test strip to the blood drop. The strip will automatically draw the blood into the reaction area. Do not apply blood to the top of the strip.
- Read Results: The meter will display your blood glucose result in 5 seconds. The PRO test strip features an improved silver electrode for better conductivity, ensuring accurate and stable results compliant with ISO 15197:2015 standards.
- Dispose Safely: Remove the used test strip and lancet from the meter and lancing device, respectively. Dispose of them safely in a puncture-resistant container (sharps container).

Image: A Sinocare AQ Pro I meter displaying a blood glucose reading, emphasizing the 5-second measurement time and wide HCT range (10%-70%).

Image: A diagram showing the five-electrode system of the test strip, which helps eliminate interference and provides more accurate results.

Image: A detailed diagram illustrating the structure of the test strip, indicating the blood suction end and the insertion end for the instrument.
4. Maintenance
4.1 Storage Conditions
- Store test strips and lancets in their original packaging in a cool, dry place.
- Keep away from direct sunlight and heat sources.
- Recommended storage temperature: 10-40°C (50-104°F).
- Recommended humidity: ≤90% RH.
- Do not refrigerate or freeze.
4.2 Usage Period
Once the test strip vial is opened, use the remaining strips within 3 months to ensure accuracy and prevent expiration. Always check the expiration date on the vial before use.
4.3 Disposal
Used test strips and lancets are biohazardous waste. Dispose of them in a designated sharps container immediately after use. Follow local regulations for proper disposal of medical waste.
5. Troubleshooting
If you encounter issues during testing, consider the following common problems and solutions:
- Inaccurate Readings:
- Ensure hands are clean and dry before testing.
- Check the expiration date of the test strips.
- Ensure the test strip vial cap was tightly closed after removing a strip.
- Verify sufficient blood sample size.
- Confirm the test strip is fully inserted into the meter.
- Meter Not Turning On:
- Ensure the test strip is inserted correctly.
- Check the batteries of your Sinocare AQ Pro I Blood Glucose Meter.
- Error Messages:
- Refer to your Sinocare AQ Pro I Blood Glucose Meter's user manual for specific error codes and their meanings.
- Common errors may relate to temperature, strip damage, or insufficient blood.
If problems persist, contact Sinocare customer support for assistance.
6. Specifications
| Feature | Detail |
|---|---|
| Product Name | Sinocare AQ Pro I Blood Glucose Test Strips and Lancets |
| Model Number | PRO 50 Strisce |
| Contents | 50 Test Strips, 50 Sterile Lancets |
| Measurement Time | 5 seconds |
| HCT Range | 10% - 70% |
| Measurement Temperature | 10-40°C (50-104°F) |
| Humidity Range | ≤90% RH |
| Compatibility | Only with Sinocare AQ Pro I Blood Glucose Meter |
| Accuracy Standard | ISO 15197:2015 |
| GTIN (UPC) | 00810166320696 |
7. Warranty and Support
For any questions, concerns, or technical support regarding your Sinocare AQ Pro I Blood Glucose Test Strips and Lancets, please contact Sinocare customer service. Refer to the contact information provided with your original glucometer kit or visit the official Sinocare website for support details.
Sinocare is committed to providing high-quality products and support to ensure your satisfaction and effective blood glucose management.