1. Product Overview

The Jiayin JYPC-2 is an electromagnetic water pump designed for various applications requiring precise fluid delivery. This pump operates on AC 220V-240V and is suitable for use with water or non-corrosive liquids. Its robust design ensures reliable performance and longevity.

Key Features:

  • Corrosion-resistant construction for durability.
  • Stable flow rate of 100 ± 10% cc/min.
  • Designed for continuous operation (ED100%).
  • Compatible with AC 220V-240V, 50Hz power supply.
  • Suitable for water and non-corrosive liquids.

2. Safety Instructions

Please read and understand all safety instructions before installing, operating, or maintaining the pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.

  • Electrical Safety: Ensure the pump is connected to a power supply matching the specified voltage (AC 220V-240V, 50Hz). Always disconnect power before performing any installation, maintenance, or troubleshooting.
  • Liquid Compatibility: Use only with water or non-corrosive liquids. Using corrosive or flammable liquids can damage the pump and create hazardous conditions.
  • Temperature Limits: Do not exceed the maximum operating temperatures: ambient temperature 70℃ (158℉) and medium temperature 60℃ (140℉).
  • Installation: Ensure all connections are secure and leak-free. Mount the pump in a stable position to prevent vibration or movement during operation.
  • Children and Pets: Keep the pump and its connections out of reach of children and pets.
  • Professional Installation: If you are unsure about any installation steps, consult a qualified professional.

3. Setup and Installation

Follow these steps for proper installation of your Jiayin JYPC-2 pump.

3.1 Unpacking

  • Carefully remove the pump from its packaging.
  • Inspect the pump for any signs of damage during transit. Do not install if damaged.

3.2 Mounting

Mount the pump securely in a location that is stable and allows for easy access for connections and maintenance. Ensure adequate ventilation around the pump.

3.3 Fluid Connections

  1. Identify the inlet and outlet ports on the pump. The pump typically has barbed fittings for hose connections.
  2. Connect the fluid supply hose to the inlet port and the output hose to the outlet port. Ensure hoses are securely fastened with clamps if necessary to prevent leaks.
  3. Verify that the hoses are not kinked or obstructed.
Jiayin JYPC-2 pump with dimensions and technical parameters

Figure 1: Jiayin JYPC-2 pump with detailed dimensions and technical specifications. This image illustrates the physical layout, inlet/outlet positions, and critical measurements for installation.

Angled view of Jiayin JYPC-2 pump showing electrical connections and fluid ports

Figure 2: Angled view of the Jiayin JYPC-2 pump, highlighting the electrical terminals and the barbed fluid connectors on both ends.

3.4 Electrical Connection

  1. Ensure the power supply is OFF before making any electrical connections.
  2. Connect the pump to an AC 220V-240V, 50Hz power source. Refer to the pump's label for specific wiring instructions if provided.
  3. Ensure all electrical connections are secure and properly insulated to prevent short circuits or electric shock.

4. Operating Instructions

Once the pump is installed and all connections are secure, you can begin operation.

  1. Prime the Pump (if necessary): Depending on your system, you may need to prime the pump by ensuring the inlet hose and pump chamber are filled with liquid before starting.
  2. Power On: Turn on the power supply to the pump. The pump should begin to operate, drawing liquid through the system.
  3. Monitor Operation: Observe the pump during its initial operation for any unusual noises, leaks, or signs of malfunction.
  4. Continuous Operation: The Jiayin JYPC-2 pump is designed for continuous duty (ED100%), meaning it can operate without interruption within its specified temperature and liquid parameters.
  5. Power Off: To stop the pump, simply turn off the power supply.

5. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your pump.

  • Regular Inspection: Periodically inspect the pump and all connections for any signs of wear, damage, or leaks.
  • Cleaning: If the pump is used with liquids that may leave residue, periodically flush the pump with clean water or a suitable non-corrosive cleaning solution. Ensure the pump is disconnected from power before cleaning.
  • Check for Blockages: If flow rate decreases, check the inlet and outlet hoses and the pump's internal passages for any blockages or debris.
  • Storage: If storing the pump for an extended period, ensure it is clean and dry. Store in a cool, dry place.

6. Troubleshooting

This section provides solutions to common issues you might encounter with your Jiayin JYPC-2 pump.

6.1 Pump Does Not Start

  • Check Power Supply: Ensure the pump is properly connected to a live AC 220V-240V, 50Hz power outlet. Verify the power switch is on.
  • Check Electrical Connections: Inspect all wiring for loose or damaged connections.
  • Internal Fault: If power is confirmed and connections are secure, the pump may have an internal fault. Contact support.

6.2 Low Flow Rate or No Flow

  • Check for Blockages: Inspect inlet and outlet hoses, as well as the pump's internal passages, for any debris or obstructions.
  • Verify Liquid Level: Ensure there is sufficient liquid supply to the pump.
  • Air in System: If the pump is not self-priming, ensure it has been properly primed and there is no air trapped in the system.
  • Kinked Hoses: Check that hoses are not bent or kinked, restricting flow.

6.3 Leaks

  • Check Connections: Tighten all hose connections and ensure they are properly sealed. Use hose clamps if necessary.
  • Damaged Hoses/Pump: Inspect hoses and the pump body for cracks or damage. Replace any damaged components.

7. Specifications

ParameterValue
Model NumberJYPC-2
VoltageAC 220V-240V
Frequency50Hz
Power16W
Flow Rate100 ± 10% cc/min
Operating MediumWater or non-corrosive liquid
Ambient Operating TemperatureUp to 70℃ (158℉)
Medium Operating TemperatureUp to 60℃ (140℉)
Duty CycleED100% (Continuous)
Maximum Pressure3.0 bar
Noise Level38 dB
Dimensions (L x W x H)7.85 x 3.8 x 7.85 cm (3.09 x 1.5 x 3.09 inches)
Weight116 Grams (0.25 lbs)
MaterialPlastic, Copper, Steel

Note: Specifications are subject to change without notice.

8. Warranty and Support

For warranty information and technical support, please refer to the documentation provided at the time of purchase or contact your seller directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.