AC Infinity AC-TWT8

AC Infinity Room to Room Fan 8" with Temperature Controller - Instruction Manual

Model: AC-TWT8

Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your AC Infinity Room to Room Fan, Model AC-TWT8. This in-wall ventilation fan is designed to quietly circulate air between rooms, helping to maintain a balanced temperature and improve overall airflow within your living or working space.

The fan features an intelligent digital controller for precise temperature, timer, and cycle programming. Its airflow is digitally reversible, allowing for easy transition between intake and exhaust functions. The EC motor with PWM controls ensures quiet operation across ten precise speed levels.

AC Infinity Room to Room Fan 8 inch, front view

Image: Front view of the AC Infinity Room to Room Fan 8-inch, Model AC-TWT8, showcasing its sleek design and integrated digital display.

Product Features

  • Room Temperature Balancing: Designed to transfer air between rooms for consistent temperature.
  • Intelligent Digital Controller: Features 10 precise fan speeds with temperature, timer, and cycle programming options.
  • Reversible Airflow: Digitally reversible airflow system allows switching between intake and exhaust with a single button.
  • Efficient EC Motor: Next-generation EC motor with PWM controls and dual ball bearings for quiet and durable operation.
  • Durable Construction: Housed in a flush-mount heavy-duty frame with stainless steel inner frame for longevity and resistance to debris.
  • Compact Dimensions: 10.15 x 10.15 x 4.58 inches (L x W x D) with an 8-inch fan diameter.
  • Airflow Capacity: Provides up to 305 CFM (Cubic Feet Per Minute).
  • Low Noise Level: Operates at a noise level of 48 dBA.
AC Infinity Room to Room Fan installed in a wall, showing airflow direction

Image: The AC Infinity Room to Room Fan installed in a wall, illustrating how it circulates air between two rooms to balance temperature.

Setup and Installation

Proper installation is crucial for optimal performance and safety. It is recommended to consult a qualified professional for installation if you are unfamiliar with electrical wiring or wall modifications.

Required Tools (Typical):

  • Measuring tape
  • Pencil
  • Stud finder
  • Drywall saw or jigsaw
  • Drill
  • Screwdriver
  • Level

Installation Steps:

  1. Select Location: Choose a wall location between the two rooms where temperature balancing is desired. Ensure there are no electrical wires, plumbing, or structural elements in the chosen area.
  2. Measure and Mark: Use the provided template (if included) or the fan's dimensions (10.15" x 10.15") to mark the cutout area on both sides of the wall. Ensure the markings align precisely. Measure twice, cut once.
  3. Cut Opening: Carefully cut the marked opening in the wall using a drywall saw or jigsaw.
  4. Prepare Wiring: If hardwiring, ensure power is off at the circuit breaker. Route electrical wiring to the fan's location according to local electrical codes. The fan can also be used with a standard plug-in method if an outlet is nearby.
  5. Insert Fan: Insert the fan unit into the wall opening. The two tubes of the fan are designed to fit into each other.
  6. Secure Fan: Secure the fan's faceplates to the wall using screws. Ensure the fan is level and flush with the wall surface.
  7. Connect Power: Connect the power cord to an appropriate outlet or complete the hardwiring connections.
  8. Test Operation: Restore power and test the fan's basic functions.
AC Infinity Room to Room Fan installed in a modern bathroom setting

Image: The AC Infinity Room to Room Fan seamlessly installed in a wall, demonstrating its discreet integration into a modern interior.

Operating Instructions

The digital controller provides various modes and settings to optimize your fan's performance.

Close-up of the AC Infinity fan's digital controller with settings

Image: A detailed view of the fan's digital controller, highlighting the display and control buttons for various settings like temperature, speed, and programming.

Controller Functions:

  • Power Button: Turns the fan ON or OFF.
  • Mode Button: Cycles through available operating modes (e.g., AUTO, ON, TIMER, CYCLE).
  • Up/Down Arrows: Adjust fan speed (1-10 levels), temperature settings, or timer durations.
  • Settings Button (Gear Icon): Accesses advanced programming options.
  • Airflow Direction Button: Reverses the direction of airflow (intake or exhaust).

Operating Modes:

  • ON Mode: Fan runs continuously at a set speed (1-10).
  • AUTO Mode: Fan activates based on temperature triggers. You can set a high temperature threshold for exhaust or a low temperature threshold for intake. The fan speed can incrementally increase as the temperature deviates further from the set point.
  • TIMER Mode: Fan runs for a specified duration and then turns off.
  • CYCLE Mode: Fan alternates between ON and OFF periods for continuous cycling. Set "Cycle On" duration and "Cycle Off" duration. The fan speed during "Cycle On" is determined by the speed set in ON mode.

Reversible Airflow:

The fan's unique design allows for easy reversal of airflow direction. Press the dedicated airflow button on the controller to switch between drawing air into the room (intake) or expelling air from the room (exhaust). This feature is useful for adapting to seasonal changes or specific ventilation needs.

Diagram showing alternating airflow direction of the fan

Image: A diagram illustrating the alternating airflow capability of the fan, showing air moving in both directions through the wall.

Maintenance

Regular maintenance ensures the longevity and efficient operation of your AC Infinity Room to Room Fan.

  • Cleaning: Periodically clean the fan grilles and blades to prevent dust buildup, which can reduce airflow and efficiency. Use a soft, dry cloth or a vacuum cleaner with a brush attachment.
  • Power Disconnection: Always disconnect power to the fan at the circuit breaker before performing any cleaning or maintenance.
  • Inspection: Annually inspect the fan for any signs of wear, loose connections, or unusual noises.
  • Avoid Liquids: Do not use liquid cleaners directly on the fan or its electrical components.
Close-up of the fan's durable build and internal components

Image: A close-up view highlighting the durable construction of the fan, including its heavy-duty faceplates and internal components designed for long-lasting performance.

Troubleshooting

If you encounter issues with your fan, refer to the following common troubleshooting steps:

  • Fan Not Turning On:
    • Check if the power cord is securely plugged in.
    • Verify that the circuit breaker for the fan's power source is not tripped.
    • Ensure the fan is not in a programmed OFF state (e.g., timer or cycle off).
  • Reduced Airflow:
    • Inspect fan grilles and blades for dust or obstructions. Clean if necessary.
    • Check the fan speed setting on the controller; increase if it's too low.
  • Unusual Noise:
    • Ensure the fan is securely mounted and not vibrating against the wall.
    • Check for any foreign objects that may have entered the fan housing.
    • Verify that the fan speed is not set excessively high, as higher speeds naturally produce more sound.
  • Controller Not Responding:
    • Try cycling the power to the fan (unplug and replug, or reset circuit breaker).
    • Refer to the full product manual for specific controller reset procedures if available.

If problems persist after attempting these steps, please contact AC Infinity customer support for further assistance.

Specifications

FeatureDetail
Model NameAC-TWT8
Fan Diameter8 Inches
Product Dimensions (D x W x H)6.89"D x 10.16"W x 10.16"H
Air Flow Capacity305 Cubic Feet Per Minute (CFM)
Noise Level48 dBA
Wattage16 watts
Voltage100 Volts
Number of Power Levels10
Special FeatureReversible Airflow
Control MethodRemote (via integrated digital controller)
Item Weight4.81 pounds
Indoor/Outdoor UsageIndoor
UPC819137023338
Technical specifications diagram for AC Infinity Room to Room Fan

Image: A diagram detailing the technical specifications and dimensions of the AC Infinity Room to Room Fan, including its model, design, power usage, engine type, airflow, noise level, and sensor type.

Warranty and Support

For warranty information, please refer to the documentation included with your product or visit the official AC Infinity website. AC Infinity typically offers a manufacturer's warranty covering defects in materials and workmanship.

If you require technical assistance, have questions about installation, operation, or troubleshooting that are not covered in this manual, please contact AC Infinity customer support directly. Contact details can usually be found on the product packaging or the official AC Infinity website.

AC Infinity Official Website: www.acinfinity.com

© 2023 AC Infinity. All rights reserved.

This manual is for informational purposes only. Specifications are subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.