1. Introduction
This manual provides comprehensive instructions for the installation, setup, operation, and maintenance of your ROINTE ST.2 TSETI03 Underfloor Heating Thermostat. Please read this manual carefully before using the device to ensure proper function and safety. The ST.2 TSETI03 thermostat is designed to control underfloor heating systems, offering programmable settings for optimal comfort and energy efficiency.
2. Safety Information
WARNING: Electrical installation should only be performed by a qualified electrician in accordance with local electrical codes and regulations.
- Always disconnect power at the main circuit breaker before performing any installation or maintenance.
- Ensure the thermostat is installed in a dry location, away from direct sunlight, drafts, or heat sources that could affect temperature readings.
- Do not expose the device to water or excessive humidity.
- Keep out of reach of children.
3. Product Overview
The ROINTE ST.2 TSETI03 thermostat features a large display and intuitive controls for managing your underfloor heating system. It allows for easy programming with up to 6 periods per day.

Figure 1: Front view of the ROINTE ST.2 TSETI03 Underfloor Heating Thermostat. The image displays a white rectangular thermostat with a large blue-backlit LCD screen. The screen shows two temperature readings, 13.0°C on the left and 15.1°C on the right, along with small icons indicating modes or settings. Below the screen are four dark grey buttons: a menu button (three horizontal lines), an up arrow, a down arrow, and a power button (circle with a vertical line). A small horizontal slot is visible below the buttons.
3.1. Components and Controls
- LCD Display: Shows current temperature, set temperature, operating mode, and programming information. Features a backlight for visibility.
- Menu Button (≡): Accesses settings and programming options.
- Up Arrow Button (▲): Increases temperature, navigates menus, or adjusts settings.
- Down Arrow Button (▼): Decreases temperature, navigates menus, or adjusts settings.
- Power Button (⏻): Turns the thermostat on or off.
4. Installation
This section provides general guidelines for installing the ROINTE ST.2 TSETI03 thermostat. For detailed wiring diagrams and specific electrical connections, refer to the separate installation guide provided with the product or consult a qualified electrician.
4.1. Mounting Location
- Install the thermostat on an interior wall, approximately 1.5 meters (5 feet) above the floor.
- Avoid locations near windows, doors, air vents, or direct sunlight, as these can affect temperature accuracy.
- Ensure there is sufficient space for wiring and access to the device.
4.2. Wiring (Professional Installation Recommended)
The thermostat requires connection to the main power supply and the underfloor heating elements. Incorrect wiring can cause damage to the device, the heating system, or pose a safety hazard. It is strongly recommended that a certified electrician performs the wiring.
- Disconnect Power: Turn off the main power supply to the heating circuit at the consumer unit/breaker box.
- Mount Base Plate: Secure the thermostat's base plate to the wall using appropriate screws.
- Connect Wires: Connect the live, neutral, and load wires from the heating system and power supply to the corresponding terminals on the thermostat's base plate. Ensure all connections are secure.
- Attach Thermostat: Carefully attach the thermostat unit to the base plate.
- Restore Power: Once installation is complete and verified, restore power to the circuit.
5. Initial Setup
After installation and power-up, the thermostat may require initial configuration.
5.1. Setting Date and Time
- Press the Menu button (≡) to enter the settings menu.
- Navigate using the Up (▲) and Down (▼) buttons to find the "Time" or "Date" setting.
- Press Menu again to select the option.
- Adjust the values (hour, minute, day, month, year) using the Up (▲) and Down (▼) buttons.
- Press Menu to confirm each setting and move to the next, or to exit the time/date setting.
5.2. Temperature Unit Selection
The thermostat typically displays temperature in Celsius (°C). If Fahrenheit (°F) is desired, this can usually be changed in the settings menu.
- Access the settings menu via the Menu button (≡).
- Locate the "Unit" or "Temp Unit" option.
- Select the desired unit (°C or °F) using the Up (▲) and Down (▼) buttons.
- Confirm your selection.
6. Operating Instructions
6.1. Power On/Off
Press the Power button (⏻) to turn the thermostat on or off. When off, the display may show a standby indicator or remain blank.
6.2. Adjusting Temperature
In normal operating mode, use the Up (▲) and Down (▼) buttons to manually adjust the desired set temperature. The new setting will typically override any programmed schedule until the next scheduled period begins.
6.3. Programming Schedule
The ST.2 TSETI03 allows for up to 6 programmable periods per day, enabling you to set different temperatures at different times.
- Press the Menu button (≡) to access the programming menu.
- Navigate to the "Program" or "Schedule" option.
- Select the day or group of days you wish to program (e.g., Mon-Fri, Sat-Sun, or individual days).
- For each period (e.g., Morning, Day, Evening, Night), set the start time and the desired temperature using the Up (▲) and Down (▼) buttons.
- Confirm each setting with the Menu button.
- Repeat for all desired periods and days.
- Exit the programming menu to save changes.
6.4. Operating Modes
Your thermostat may offer various operating modes:
- Auto Mode: Follows the programmed schedule.
- Manual Mode: Maintains a constant set temperature, overriding the schedule.
- Holiday Mode: Sets a reduced temperature for an extended period, saving energy while you are away.
- Frost Protection Mode: Maintains a minimum temperature to prevent pipes from freezing.
Refer to the on-screen icons and menu options to select and activate these modes.
7. Maintenance
The ROINTE ST.2 TSETI03 thermostat requires minimal maintenance.
- Cleaning: Wipe the thermostat's surface with a soft, damp cloth. Do not use abrasive cleaners, solvents, or chemical sprays, as these can damage the plastic and electronic components.
- Dusting: Regularly dust the device to prevent accumulation that could affect performance or sensor readings.
- No User-Serviceable Parts: Do not attempt to open or repair the thermostat yourself. This will void the warranty and could lead to electrical hazards.
8. Troubleshooting
If you experience issues with your thermostat, consult the following table before contacting support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Thermostat display is blank. | No power supply. | Check the circuit breaker. Ensure the thermostat is properly wired and connected to power. |
| Heating system not responding. | Incorrect wiring; Thermostat in OFF mode; Set temperature is below ambient. | Verify wiring (consult electrician). Press Power button to turn ON. Increase set temperature above current room temperature. |
| Temperature reading seems inaccurate. | Thermostat location affected by drafts, direct sunlight, or heat sources. | Relocate the thermostat if possible, or shield it from external influences. Allow time for the sensor to stabilize. |
| Programming schedule not working. | Thermostat in Manual mode; Incorrect time/date setting; Programming errors. | Switch to Auto mode. Verify and correct date/time. Re-enter programming schedule carefully. |
If the problem persists after attempting these solutions, please contact ROINTE customer support or a qualified technician.
9. Specifications
| Brand | ROINTE |
| Model Number | TSETI03 |
| Control Type | Button Control |
| Style | Modern |
| Backlight | Yes |
| Package Dimensions | 10 x 10 x 7 cm |
| Item Weight | 300 g |
10. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official ROINTE website. Keep your proof of purchase for warranty claims.