Introduction
This manual provides comprehensive instructions for the safe and effective operation, setup, maintenance, and troubleshooting of your MTHAT 6in1 Kim8 System Body Machine. Please read this manual thoroughly before using the device and retain it for future reference.
The MTHAT 6in1 Kim8 System is a versatile device designed for various body applications, featuring multiple functions integrated into one compact unit. This version 2.0 includes an updated design and an external filter for enhanced performance.
Safety Information
WARNING: Read all safety warnings and instructions before using this product. Failure to follow the warnings and instructions may result in electric shock, fire, or serious injury.
- Ensure the device is connected to a grounded power outlet of the correct voltage.
- Do not operate the machine with wet hands or in damp environments.
- Keep the device out of reach of children and pets.
- Do not disassemble or attempt to repair the device yourself. Contact qualified personnel for service.
- Unplug the device from the power source when not in use or before cleaning.
- Consult a healthcare professional before use if you have any medical conditions, are pregnant, or have implanted medical devices.
- Avoid direct contact with eyes and sensitive areas.
- Use only accessories and attachments provided or approved by MTHAT.
Product Overview
The MTHAT 6in1 Kim8 System Body Machine integrates multiple functions for comprehensive application. Below is an overview of the main unit and its various attachments.

Figure 1: Main unit and included treatment heads.
This image shows the main console of the Kim8 System, featuring a central display screen and multiple ports for connecting various treatment heads. Below the main unit, six different treatment heads are displayed, indicating the multi-functional capabilities of the machine.
Components:
- Main Console: The central unit housing the control panel, display screen, and connection ports.
- Vacuum & Bipolar RF Head: For combined vacuum suction and radiofrequency treatments.
- Tripolar RF Head: For targeted radiofrequency applications.
- RF Body Head: Larger radiofrequency head for body areas.
- RF Face Head: Smaller radiofrequency head for facial areas.
- Laser Lipolysis Pads: Multiple pads designed for laser-assisted treatments.
- External Filter: An updated feature for improved performance and longevity.

Figure 2: Laser Lamp Technology.
This image highlights a key feature of the MTHAT Kim8 System: the use of advanced laser lamps in its pads, as opposed to standard LED lights found in some other products. The "OUR PRODUCTS" section shows a circuit board with multiple gold-colored laser emitters, emphasizing the quality and effectiveness of the laser lipolysis function.
Setup
Follow these steps for the initial setup of your 6in1 Kim8 System Body Machine.
- Unpacking: Carefully remove all components from the packaging. Verify that all parts listed in the product overview are present and undamaged.
- Placement: Place the main console on a stable, flat surface, ensuring adequate ventilation around the unit.
- Connecting Treatment Heads: Identify the corresponding ports on the back of the main console for each treatment head. Each port is typically labeled or uniquely shaped to prevent incorrect connections.
- Power Connection: Connect the power cord to the power input on the back of the main console, then plug the other end into a grounded electrical outlet.
- External Filter Installation: Locate the external filter connection point (if not pre-installed) and securely attach the filter according to the diagram.

Figure 3: Rear panel connections and installation tips.
This image provides a detailed view of the rear panel of the Kim8 System, illustrating the various connection points for the different treatment heads and the main power input. It also highlights "INSTALLATION TIPS" with arrows pointing from the heads to their respective ports, guiding the user on correct assembly.
Once all connections are secure, the machine is ready for operation.
Operating Instructions
The 6in1 Kim8 System offers multiple functions. Always ensure the skin is clean and dry before application. It is recommended to use a conductive gel for RF treatments.
- Power On: Press the main power switch located on the back or front of the console. The display screen will illuminate.
- Function Selection: Use the touch screen or control buttons to navigate the menu and select the desired function (e.g., Vacuum & Bipolar RF, Tripolar RF, RF Body, RF Face, Laser Lipolysis).
- Parameter Adjustment: Adjust intensity levels, time settings, and mode (if applicable) according to the specific treatment area and user comfort. Start with lower settings and gradually increase as needed.
- Application:
- RF Heads (Vacuum & Bipolar, Tripolar, Body, Face): Apply a thin layer of conductive gel to the treatment area. Place the head firmly on the skin and move it in slow, circular, or linear motions.
- Laser Lipolysis Pads: Place the pads directly onto the target areas of the body. Secure them if necessary.
- Monitoring: Observe the skin's reaction during treatment. If any discomfort or excessive redness occurs, reduce the intensity or stop the treatment.
- Treatment Completion: Once the desired treatment time is complete, turn off the selected function on the console.
- Power Off: After all treatments are finished, press the main power switch to turn off the machine and unplug it from the power outlet.

Figure 4: Examples of treatment applications.
This image demonstrates various ways the Kim8 System can be used on different body parts. It shows a person receiving a back treatment, a leg treatment, a facial treatment, and an arm treatment, illustrating the versatility of the machine's different heads for various applications.

Figure 5: Laser Lipolysis Pads in detail.
This close-up image focuses on the laser lipolysis pads, showing their compact design and how they are stored or connected to the side of the main unit. This provides a clear view of the individual pads used for targeted treatments.
Maintenance
Proper maintenance ensures the longevity and optimal performance of your MTHAT 6in1 Kim8 System.
- Cleaning the Main Unit: Wipe the main console with a soft, dry cloth. For stubborn marks, use a slightly damp cloth with a mild, non-abrasive cleaner. Ensure no liquid enters the vents or ports.
- Cleaning Treatment Heads: After each use, wipe the surface of the treatment heads with a clean, damp cloth. For RF heads, ensure all conductive gel residue is removed. Do not immerse heads in water.
- External Filter: Regularly check and clean or replace the external filter as per the instructions provided with the filter. A clogged filter can affect machine performance.
- Storage: Store the machine and its accessories in a clean, dry place, away from direct sunlight and extreme temperatures.
- Cord Care: Do not wrap the power cord tightly around the machine. Avoid kinking or damaging the cord.
Troubleshooting
This section addresses common issues you might encounter. For problems not listed here, please contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Machine does not power on. | Power cord not securely plugged in; Power switch off; No power from outlet. | Check power cord connection; Ensure power switch is ON; Test outlet with another device. |
| No output from treatment head. | Head not properly connected; Function not selected; Intensity too low. | Ensure head is securely plugged into its port; Select the desired function on the display; Increase intensity gradually. |
| Display screen is blank. | Machine not powered on; Screen sleep mode. | Check power connection and switch; Touch the screen or press any button to wake it up. |
| Machine overheats. | Poor ventilation; Prolonged use at high intensity. | Ensure adequate space around the machine for airflow; Reduce treatment duration or intensity; Allow machine to cool down. |
Specifications
Technical details for the MTHAT 6in1 Kim8 System Body Machine.
| Attribute | Detail |
|---|---|
| Model | Kim8 System (Manufacturer Reference: 0901) |
| Brand | MTHAT |
| Functions | 6-in-1 (Vacuum & Bipolar RF, Tripolar RF, RF Body, RF Face, Laser Lipolysis) |
| Version | 2.0 Updated Version |
| Power Input | Standard AC (Voltage details not specified, refer to product label) |
| Dimensions (Approx.) | 9.25in (23.5cm) Width x 8.66in (22cm) Depth x 12.8in (32.5cm) Height |
| Date First Available | 11 September 2022 |

Figure 6: Product Dimensions.
This image provides a clear visual representation of the machine's dimensions, showing its width, depth, and height measurements for easy reference.
Warranty and Support
Your MTHAT 6in1 Kim8 System Body Machine comes with a one-year warranty from the date of purchase.
This warranty covers manufacturing defects and malfunctions under normal use. It does not cover damage caused by misuse, accidents, unauthorized modifications, or failure to follow the instructions in this manual.
Customer Support:
For warranty claims, technical assistance, or any questions regarding your product, please contact MTHAT customer support through your original point of purchase or refer to the contact information provided with your product packaging.
Please have your model number (0901) and purchase date ready when contacting support.