Introduction
This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of your YATO YT-73201 Infrared Thermometer. Please read this manual thoroughly before using the device and retain it for future reference.
Safety Information
Observe the following safety precautions to prevent injury or damage to the device:
- Laser Safety: This device uses a Class 2 laser. Do not stare directly into the laser beam or point it at people or animals. Avoid direct eye exposure.
- Not for Medical Use: This thermometer is designed for industrial and automotive applications and is not intended for measuring human or animal body temperature.
- Environmental Conditions: Do not expose the device to extreme temperatures, high humidity, corrosive environments, or strong electromagnetic fields.
- Maintenance: Do not attempt to disassemble or modify the device. Refer all servicing to qualified personnel.
- Battery Handling: Dispose of batteries according to local regulations. Do not mix old and new batteries or different types of batteries.
Product Overview
The YATO YT-73201 is a non-contact infrared thermometer designed for accurate temperature measurements across a wide range. Its robust ABS casing ensures durability for various applications.

Figure 1: YATO YT-73201 Infrared Thermometer and its retail packaging.

Figure 2: Front view of the thermometer, highlighting the infrared sensor and laser pointer.

Figure 3: The product's retail box, displaying key features and specifications.
Setup
Battery Installation
The YATO YT-73201 thermometer is powered by micro batteries (AAA type). To install or replace batteries:
- Locate the battery compartment cover, typically on the handle.
- Open the cover by sliding or unlatching it.
- Insert the required number of micro batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Close the battery compartment cover securely.
The device is now ready for use.
Operating Instructions
Taking a Measurement
- Point the thermometer's sensor towards the target object. Ensure the laser pointer (if activated) indicates the center of the measurement area.
- Press and hold the trigger button. The display will show the current temperature reading.
- Release the trigger button to hold the last measured temperature on the display (indicated by "HOLD").
Changing Temperature Units (Celsius/Fahrenheit)
To switch between Celsius (°C) and Fahrenheit (°F):
- With the device powered on, press the "MODE C/F" button, typically located below the display.
- The display will switch between °C and °F.

Figure 4: Close-up of the thermometer's display, showing temperature, MAX reading, and mode buttons.

Figure 5: Side view of the thermometer, illustrating the location of the control buttons.
Maintenance
Cleaning
To ensure accurate readings and prolong the life of your thermometer:
- Clean the lens and sensor regularly with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Wipe the device body with a slightly damp cloth.
- Ensure the device is completely dry before storage or next use.
Storage
Store the thermometer in a cool, dry place, away from direct sunlight and extreme temperatures. Remove batteries if the device will not be used for an extended period.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on | Low or dead batteries; incorrect battery installation. | Replace batteries with new ones, ensuring correct polarity. |
| Inaccurate readings | Dirty sensor lens; distance to target too far; emissivity setting incorrect (if applicable, though not specified for this model); extreme ambient temperature changes. | Clean the sensor lens. Ensure proper measurement distance. Allow the device to acclimate to ambient temperature. |
| Display shows "Err" or similar error | Measurement out of range; internal error. | Ensure target temperature is within the device's specified range (-50°C to 650°C). If error persists, contact support. |
Specifications
| Feature | Detail |
|---|---|
| Model Number | YT-73201 |
| Measurement Range | -50°C to 650°C |
| Measurement Accuracy | +/- 1.5°C (or 1.5% of reading, whichever is greater, typical for IR thermometers) |
| Casing Material | ABS (Acrylonitrile Butadiene Styrene) |
| Power Source | Battery powered (Micro/AAA type) |
| Product Dimensions (L x W x H) | 18.2 x 8.9 x 7.4 cm |
| Product Weight | 100 grams (device only), 179 grams (packaged) |
| Manufacturer | YATO |
| Care Instructions | Clean with a soft, damp cloth. |
Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact YATO customer service directly. Contact details can typically be found on the manufacturer's official website or product packaging.