1. Introduction
Thank you for choosing the Morelian CM81 Smart AC Clamp Multimeter. This device is a high-precision, multi-functional, and portable electrical testing tool designed for both professional and home use. It offers a wide range of measurement capabilities, including AC/DC voltage, AC current, resistance, capacitance, frequency, diode, and continuity tests. Its compact design, large backlit LCD screen, and advanced features like non-contact voltage detection and automatic shutdown make it an essential tool for electrical maintenance and troubleshooting.
2. Safety Information
WARNING: To avoid possible electric shock, fire, or personal injury, please read all safety information before you use the product. Improper use of this meter can cause damage, shock, injury or death. Always follow all safety procedures and precautions.
- Do not exceed the maximum input value specified for any function.
- Do not use the meter if it is damaged or if the test leads are damaged.
- Exercise extreme caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. Such voltages pose a shock hazard.
- Remove the test leads from the circuit before changing functions.
- Always ensure the meter is in the correct function and range for the measurement.
- Do not operate the meter around explosive gas, vapor, or dust.
- Use caution when measuring current on live circuits. Only clamp around a single conductor for current measurement.
3. Product Overview
3.1 Key Features
- Multi-functional Clamp Meter: Measures AC/DC voltage, 600A AC current, resistance, capacitance, frequency, diode, and continuity.
- Real-time Temperature Display: Convenient for checking ambient temperature.
- Large Jaw Design: 36mm clamp head for non-invasive current measurement on single-strand wires.
- Convenient Data Review: Large backlit LCD screen with data hold function.
- Compact and Portable: Small body with full functionality and easy one-handed operation.
- Durable ABS Material Body: Good electrical insulation, durable, and anti-drop.
- Other Features: Non-contact inductive voltage measurement (NCV), built-in flashlight, and automatic shutdown.
3.2 Device Components




4. Setup
4.1 Battery Installation
The CM81 requires two 1.5V AAA batteries (not included). To install the batteries:
- Ensure the meter is turned off.
- Locate the battery compartment cover on the back of the meter.
- Use a screwdriver to open the battery compartment.
- Insert two AAA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
- Replace the battery compartment cover and secure it with the screw.
4.2 Connecting Test Leads
For most measurements (voltage, resistance, capacitance, diode, continuity), you will need to use the included test leads.
- Insert the black test lead into the 'COM' (Common) input jack.
- Insert the red test lead into the 'VΩHz' input jack.

4.3 Initial Power On
Press the red power button to turn on the clamp meter. The device will automatically enter the auto-identification mode for voltage, current, resistance, and capacitance measurements.
5. Operating Instructions
5.1 Automatic Measurement Mode
The CM81 features an intelligent automatic identification function. For voltage, current, resistance, and capacitance measurements, simply connect the test leads or clamp the wire, and the meter will automatically detect the type of measurement and display the reading.
5.2 AC Current Measurement
To measure AC current, use the clamp jaw. Ensure the circuit is live and safe to access.
- Turn on the meter.
- Open the clamp jaw by pressing the trigger.
- Place the clamp jaw around a single conductor of the circuit you wish to measure. Note: Only one wire can be detected, and multiple wires cannot be detected!
- Close the clamp jaw securely. The meter will display the AC current reading.


5.3 Non-Contact Voltage (NCV) Detection
The NCV function allows you to detect the presence of AC voltage without direct contact with the conductor.
- Press the 'SELECT' button to switch to NCV mode.
- Move the top part of the meter close to the conductor or outlet.
- If AC voltage is detected, the red LED will flash, and a buzzer will sound.

5.4 Data Hold Function
To freeze the current reading on the display, press the 'H/*' button. Press it again to release the data hold.
5.5 Backlight and Flashlight
Long press the 'H/*' button to turn on the screen backlight. This improves visibility in dark environments. The meter also has a built-in flashlight for illuminating the work area.
5.6 Automatic Shutdown
To conserve battery life, the CM81 will automatically turn off after 15 minutes of inactivity. To disable or re-enable this feature, refer to the full English user manual included in the package.

6. Maintenance
6.1 Cleaning
Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Periodically clean the terminals with a cotton swab and detergent; dirt or moisture in the terminals can affect readings.
6.2 Battery Replacement
When the low battery indicator appears on the display, replace the batteries immediately to ensure accurate readings. Follow the steps in Section 4.1 for battery installation.
6.3 Storage
If the meter is not to be used for a long period, remove the batteries to prevent battery leakage and damage to the meter.
7. Troubleshooting
- No Display: Check battery installation and ensure batteries are not depleted. Replace if necessary.
- Inaccurate Readings: Ensure test leads are properly connected. Check for dirty terminals. Verify the correct measurement mode is selected (though auto-ranging helps). Ensure the clamp is properly closed around a single conductor for current measurements.
- Buzzer Not Working: Check if the continuity function is selected and if the circuit is closed.
8. Specifications
| Parameter | Value |
|---|---|
| Color | Red (Optional: Black) |
| AC Voltage Range/Resolution/Accuracy | 1~600V / 0.001~1V / ±(1.5%+8) |
| DC Voltage Range/Resolution/Accuracy | 1~600V / 0.001~1V / ±(1.2%+5) |
| AC Current Range/Resolution/Accuracy | 1~600A / 1mA~0.1A / ±(2.8%+8) |
| Resistance Range/Resolution/Accuracy | 0~60MΩ / 0~10kΩ / ±(1.2%+5) |
| Capacitance Range/Resolution/Accuracy | 100pF ~ 40mF / 1pF ~ 10µF / ±(6%+10) |
| Frequency Range/Resolution/Accuracy | 10Hz ~ 20MHz / 0.1Hz ~ 10kHz / ±(4.0%+10) |
| Diode Test | Yes |
| Buzzer (Continuity) | Yes |
| Data Hold | Yes |
| Non-contact Voltage Test (NCV) | Yes |
| Flashlight | Yes |
| Low Battery Indicator | Yes |
| Real-time Temperature Display | Yes |
| Range | Auto Range |
| Automatic Shutdown | 15 minutes |
| Display | Backlit LCD Screen |
| Max Display | 6000 Counts |
| Power Source | Two 1.5V AAA batteries (not included) |
| Jaw Opening Size | 36mm / 1.41 inches |
| Product Size | 185 × 65 × 32 mm / 7.28 × 2.56 × 1.26 inches |
| Product Weight | 136g / 4.80 ounces |
| Manufacturer Part Number | TNE2100864367868XT |
| UPC | 752874090679 |
9. Warranty and Support