1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Voktta 100A DC Power Meter. This device is designed to accurately measure DC voltage, current, power, and energy consumption in various applications, including RVs, solar systems, and battery monitoring. Please read this manual thoroughly before use to ensure proper function and safety.

2. Safety Information

  • Ensure all power is disconnected before installation or wiring to prevent electric shock.
  • This device is intended for DC circuits only. Do not connect to AC power.
  • Observe correct polarity (+/-) during wiring to avoid damage to the meter and connected equipment.
  • Use appropriate wire gauges (30-12 AWG copper wires recommended) for connections to handle the expected current.
  • Do not exceed the maximum voltage (100V DC) or current (100A) ratings.
  • Keep the device away from moisture, dust, and extreme temperatures.
  • Do not attempt to disassemble or modify the meter. Refer all servicing to qualified personnel.

3. Product Overview

3.1 Key Features

  • Wide Measurement Range: DC voltage 6.5-100V, current 0-100A, power 0-10kW, energy 0-9999kWh.
  • LCD Display: Simultaneously displays voltage, current, power, and energy.
  • Power-off Data Storage: All parameters are automatically saved when power is lost.
  • Energy Reset Function: Accumulated energy data can be manually reset.
  • Over-threshold Alarm: Backlight and power display flash if active power exceeds a set threshold.
  • Manual Backlight Control: Backlight can be manually turned on or off.

3.2 Product Dimensions

Voktta 100A DC Power Meter with dimensions labeled: 89.6mm length, 44.6mm height, 24.4mm depth, 49.6mm display height.

Figure 1: Voktta 100A DC Power Meter with labeled dimensions (89.6mm x 44.6mm x 24.4mm).

3.3 Display Functions

Voktta 100A DC Power Meter LCD display showing Voltage, Current, Power, and Energy readings with corresponding units V, A, W, Wh.

Figure 2: LCD display showing Voltage (V), Current (A), Power (W), and Energy (Wh) measurements.

4. Specifications

ParameterValue
Model NumberB0B87458J7
Operating Voltage RangeDC 6.5V - 100V
Current Measurement Range0 - 100A
Power Measurement Range0 - 10kW
Energy Measurement Range0 - 9999kWh
Measurement TypeVoltmeter, Ammeter, Wattmeter, Energy Meter
Display TypeLCD with Backlight
Included Components1*Digital Voltmeter Ammeter DC 100A, 1*100A/75mV Shunt
Compliant SpecificationsIEC 61010-1
Product Dimensions (L x W x H)10 x 10 x 10 millimeters (approximate)
Weight220 grams (approximate)
Country of OriginChina

5. Setup and Installation

5.1 Basic Wiring Instruction

The meter requires a 100A/75mV shunt for current measurement. The shunt must be installed in series with the load. The meter itself connects with four wires (not included) to the shunt and the power source.

  1. Step 1: Install the 100A/75mV shunt in series with the DC circuit, between the power source (e.g., battery) and the load. Ensure correct polarity.
  2. Step 2: Connect the meter to the shunt and the power source using four wires. The meter's small wires are for its own power supply and voltage measurement, while the shunt handles the main current. Recommended wire gauge for connections to the meter is 30-12 AWG copper wires.
Diagram showing basic wiring instruction for the DC power meter. Step 1 illustrates placing the shunt in the circuit between a battery and a load. Step 2 shows connecting the meter to the shunt with four wires.

Figure 3: Basic wiring diagram for the Voktta DC Power Meter with shunt.

5.2 Solar System Wiring Instruction

This diagram illustrates wiring for a solar system where an inverter connects directly to the battery. The meter's four wires do not carry large current; they are for measurement and power. Any copper wire from 30 AWG to 12 AWG can be used for these connections.

Diagram showing solar system wiring instruction. It includes a solar panel, charge controller, battery, inverter, and multiple DC power meters with shunts to monitor different parts of the circuit.

Figure 4: Solar system wiring diagram with the Voktta DC Power Meter.

You do not need to wire both meters if monitoring a solar system; just connect the voltmeter(s) to monitor the specific parameters you require.

6. Operating Instructions

  • Power On: Once correctly wired, the meter will power on and display real-time voltage, current, power, and accumulated energy.
  • Backlight Control: The backlight can be manually toggled on or off using the button on the front panel.
  • Over-threshold Indication: If the active power exceeds a predefined threshold, the backlight and power display will flash to alert the user.
  • Energy Data Reset: To reset the accumulated energy (kWh) data, press and hold the button on the front panel for approximately 5 seconds until the energy reading resets to zero.
  • Power-off Memory: The meter automatically saves all settings and accumulated energy data when power is disconnected. This data will be restored upon power-up.

7. Maintenance

  • Clean the display and casing with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Regularly check all wiring connections to ensure they are secure and free from corrosion.
  • Ensure the operating environment is within the specified temperature and humidity ranges.

8. Troubleshooting

  • No Display:
    • Check if the power supply to the meter is connected correctly and within the 6.5-100V DC range.
    • Verify all wiring connections are secure.
  • Incorrect Readings:
    • Ensure the shunt is correctly installed in series with the load and its connections are tight.
    • Check for correct polarity of all connections.
    • Verify that the current does not exceed the 100A rating of the shunt and meter.
  • Backlight Flashing:
    • This indicates that the active power has exceeded the set threshold. This is a normal warning function.
  • Energy Data Not Resetting:
    • Ensure you are pressing and holding the reset button for at least 5 seconds.

9. Support

If you encounter any issues or have questions not covered in this manual, please do not hesitate to contact Voktta customer support. We are committed to providing assistance and will do our best to help you resolve any problems.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.