Jasco V-630

Jasco V-630 iRM UV-Vis Spectrophotometer User Manual

Model: V-630 | Wavelength Range: 190-1100nm

1. Introduction

The Jasco V-630 iRM UV-Vis Spectrophotometer is a high-performance analytical instrument designed for precise absorbance and transmittance measurements across the ultraviolet and visible spectrum (190-1100nm). Featuring an intuitive touch panel interface, this device is suitable for a wide range of applications in research, quality control, and educational settings.

Key features include:

Jasco V-630 iRM UV-Vis Spectrophotometer front view

Figure 1.1: Front view of the Jasco V-630 iRM UV-Vis Spectrophotometer, showing the main unit with the sample compartment on the left and the integrated touch panel on the right.

2. Setup

2.1 Unpacking and Inspection

Carefully remove the spectrophotometer and all accessories from the packaging. Inspect for any signs of damage during transit. Retain all packaging materials for future transport or storage.

2.2 Placement

Place the instrument on a stable, level surface away from direct sunlight, excessive vibration, and strong magnetic fields. Ensure adequate ventilation around the unit to prevent overheating. Maintain a clear space of at least 10 cm around all sides.

2.3 Power Connection

Connect the provided power cord to the instrument's power inlet and then to a grounded electrical outlet. Ensure the power supply matches the instrument's voltage requirements.

2.4 Initial Power-On

Press the power button located on the front panel. The system will initiate a self-test and calibration sequence. Allow the instrument to warm up for at least 15-30 minutes for optimal performance and stability.

Jasco V-630 iRM Spectrophotometer warranty label

Figure 2.1: Close-up view of the Jasco V-630 iRM Spectrophotometer's side panel, showing the product label with model number and manufacturer information.

3. Operating Instructions

3.1 Touch Panel Interface

The V-630 iRM features an integrated touch panel for all operational controls and data display. Navigate through menus by tapping the corresponding icons or text. Use the stylus provided for precise input if necessary.

3.2 Sample Preparation

Prepare your samples according to standard laboratory procedures. Ensure cuvettes are clean, free of scratches, and compatible with the desired wavelength range. For UV measurements, quartz cuvettes are recommended.

3.3 Measurement Procedures

  1. From the main menu, select the desired measurement mode (e.g., Absorbance, Transmittance, Quantitative Analysis).
  2. Follow the on-screen prompts to set parameters such as wavelength range, scan speed, and data interval.
  3. Insert a blank (reference) cuvette into the sample compartment and perform a baseline correction or zeroing as prompted.
  4. Replace the blank with your sample cuvette.
  5. Initiate the measurement. The results will be displayed on the touch panel.

3.4 Data Analysis and Export

The instrument allows for basic on-board data analysis. Data can typically be saved to internal memory or exported via USB or network connection (if available) for further analysis on external software.

Jasco V-630 iRM Spectrophotometer touch panel interface and sample compartment

Figure 3.1: Composite image showing the Jasco V-630 iRM's touch panel interface with various menu options and a view of the sample compartment designed for cuvettes.

4. Maintenance

4.1 Cleaning

Regularly clean the exterior of the instrument with a soft, damp cloth. For the touch panel, use a screen-specific cleaner and a microfiber cloth. Avoid abrasive cleaners or solvents. Keep the sample compartment clean and free of spills.

4.2 Calibration

Periodic calibration using certified reference materials is recommended to ensure measurement accuracy. Refer to the instrument's on-screen calibration menu or consult a qualified service technician for advanced calibration procedures.

4.3 Storage

When not in use for extended periods, power off the instrument and cover it with a dust cover to protect it from environmental contaminants. Store in a dry, temperature-controlled environment.

5. Troubleshooting

ProblemPossible CauseSolution
Instrument does not power onPower cord disconnected; Power outlet faultCheck power cord connection; Try a different outlet
Measurement errors / Inconsistent readingsDirty cuvettes; Incorrect sample preparation; Lamp nearing end of lifeClean cuvettes thoroughly; Re-prepare samples; Contact service for lamp replacement
Touch panel unresponsiveSoftware glitch; Screen calibration issueRestart the instrument; Recalibrate touch screen if option is available

For issues not listed here or if solutions do not resolve the problem, please contact Jasco customer support.

6. Specifications

7. Warranty and Support

This product is covered by the manufacturer's standard warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or contact Jasco directly. Support for the Jasco V-630 iRM Spectrophotometer is available through authorized service centers and the manufacturer's customer service channels.

For technical assistance, service requests, or to inquire about replacement parts, please visit the official Jasco website or contact their customer support line.

Related Documents - V-630

Preview JASCO V-700 Series UV-Visible/NIR Spectrophotometers: Performance, Innovation, Reliability
Explore the JASCO V-700 Series UV-Visible/NIR Spectrophotometers, offering advanced spectral characterization, thermodynamic studies, and quantitative measurements for bio- and materials research. Featuring five models with wide wavelength ranges and compact designs.
Preview JASCO Pharmaceutical Solutions Book: Advanced Spectroscopy and Chromatography Instruments
Discover JASCO's comprehensive portfolio of advanced spectroscopy and chromatography instruments, featuring detailed applications and solutions specifically designed for the pharmaceutical industry. This volume highlights the company's expertise in scientific analytical instrumentation.
Preview Jasco Products Company Limited Warranty - 90 Days
This document outlines the 90-day limited warranty for Jasco Products Company LLC. It details the terms and conditions for warranty claims, exclusions, limitations, and consumer rights.
Preview Jasco Products Company Limited Warranty - 2 Years
This document outlines the 2-year limited warranty provided by Jasco Products Company LLC for their products. It details the terms, conditions, limitations, and procedures for submitting a warranty request, emphasizing that the warranty covers manufacturing defects and is non-transferable.
Preview Jasco 46563 Z-Wave In-Wall Smart Toggle Switch: QuickFit & SimpleWire
Explore the Jasco 46563 Z-Wave In-Wall Smart Toggle Switch, designed for seamless smart home integration. Featuring QuickFit and SimpleWire technologies for simplified installation, this switch enables up to 6-way control and works with popular voice assistants like Amazon Alexa and Google Assistant. Expand your home automation capabilities with this versatile device.
Preview Jasco Pro Series Smart Water Leak Sensor (81018) - Installation & Setup Guide
Comprehensive guide for installing and setting up the Jasco Pro Series Smart Water Leak Sensor (Model 81018, ZWN6310). Learn how to connect to Z-Wave networks, troubleshoot, and utilize its features for home automation and water leak detection.