1. Introduction
The Kemot PROsinus-2600 is an advanced emergency power supply system designed to provide reliable backup power and protect your electronic devices from power outages and fluctuations. This device functions as a pure sine wave inverter with an integrated charging function, converting 24V DC power from an external battery into stable 230V AC power, while also recharging the connected battery.
Key features include comprehensive protection against overloads, short-circuits, and voltage irregularities. It offers three distinct operating modes: backup power with charging, dedicated battery charging, and pure inverter mode. Its constant phase operation ensures compatibility with sensitive appliances, such as certain gas furnaces, maintaining a stable phase regardless of the power source.

Figure 1: Operational diagram of the Kemot PROsinus-2600 inverter with connected devices.
2. Safety Instructions
Please read and understand all safety instructions before installing or operating the Kemot PROsinus-2600. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Electrical Safety: Always disconnect the inverter from all power sources (AC input and battery) before performing any maintenance or making connections.
- Ventilation: Ensure adequate ventilation around the inverter to prevent overheating. Do not block ventilation openings.
- Environment: Install the inverter in a dry, well-ventilated area, away from direct sunlight, heat sources, flammable materials, and corrosive substances.
- Battery Connections: Connect batteries with correct polarity. Incorrect polarity can damage the inverter and battery. Use appropriate gauge cables for battery connections.
- Grounding: The inverter must be properly grounded.
- Qualified Personnel: Installation and servicing should only be performed by qualified personnel.
- Children: Keep the device out of reach of children.
3. Product Overview
Familiarize yourself with the components and controls of your Kemot PROsinus-2600 inverter.
3.1 Front Panel

Figure 2: Front panel of the Kemot PROsinus-2600.
- Digital Display: Shows input/output voltage, frequency, battery status, and operational mode.
- ON/OFF Switch: Controls the main power to the inverter.
- OUTPUT & INVERTER ON/OFF Button: Activates or deactivates the inverter output.
3.2 Rear Panel

Figure 3: Rear panel of the Kemot PROsinus-2600.
- Cooling Fan: Automatically activates to dissipate heat during operation.
- AC Output Sockets: Two standard 230V AC output sockets for connecting appliances.
- Battery Terminals (24VDC): Red (+) and Black (-) terminals for connecting the external 24V battery.
- AC Input (230V): Power inlet for connecting to the main grid for charging and backup mode.
- Circuit Breaker: Provides overload protection for the AC output.
- Charger Current Switch (10A/15A): Selects the battery charging current.
4. Setup
Follow these steps for proper installation and setup of your inverter.
- Placement: Place the inverter on a stable, flat surface in a well-ventilated area. Ensure at least 10 cm of clear space around all sides for airflow.
- Battery Connection:
- Ensure the inverter's main ON/OFF switch is in the OFF position.
- Connect the positive (+) terminal of your 24V external battery to the red (+) terminal on the inverter.
- Connect the negative (-) terminal of your 24V external battery to the black (-) terminal on the inverter.
- Tighten all connections securely. Recommended battery capacity is 50-300 Ah (200 Ah recommended for optimal performance).
- AC Input Connection: Plug the inverter's AC input cable into a standard 230V AC wall outlet.
- Load Connection: Plug your appliances into the AC output sockets on the rear panel of the inverter. Ensure the total power consumption of connected devices does not exceed 1800W.

Figure 4: Detailed view of rear panel connections.
5. Operating Instructions
The Kemot PROsinus-2600 offers three operational modes:
- Backup Power with Charging Function (UPS Mode):
- Ensure the inverter is connected to both the battery and the AC mains.
- Turn the main ON/OFF switch to ON.
- Press the OUTPUT & INVERTER ON/OFF button to activate the output.
- In this mode, the inverter will power connected devices from the AC mains and simultaneously charge the battery. In case of a power outage, it will automatically switch to battery power (inverter mode) within <=4 ms.
- Charging Mode:
- Connect the inverter to the battery and the AC mains.
- Turn the main ON/OFF switch to ON.
- Do NOT press the OUTPUT & INVERTER ON/OFF button.
- The inverter will only charge the connected battery. Select the desired charging current (10A or 15A) using the switch on the rear panel. Approximate charging time is 4-14 hours, depending on battery capacity.
- Inverter Mode:
- Connect the inverter only to the battery (no AC mains connection).
- Turn the main ON/OFF switch to ON.
- Press the OUTPUT & INVERTER ON/OFF button to activate the output.
- The inverter will convert 24V DC from the battery to 230V AC to power connected devices.
5.1 Display Indicators
The digital display provides real-time information:
- Input Voltage (Vi): Shows the incoming AC voltage from the mains.
- Output Voltage (Vo): Displays the AC voltage supplied to your devices.
- Frequency (Hz): Indicates the output frequency (50Hz or 60Hz).
- Battery Level: A graphical representation of the connected battery's charge status.
- Operational Mode Icons: Icons indicating charging, inverter, or fault conditions.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your Kemot PROsinus-2600.
- Cleaning: Periodically clean the exterior of the inverter with a soft, dry cloth. Do not use liquid cleaners or solvents.
- Ventilation: Ensure that the cooling fan and ventilation openings are free from dust and obstructions. Use compressed air to clear dust if necessary.
- Connections: Regularly check all electrical connections (battery terminals, AC input, output sockets) to ensure they are secure and free from corrosion.
- Battery Care: Follow the manufacturer's recommendations for your external battery's maintenance. Ensure the battery is kept charged, especially during long periods of inactivity.
7. Troubleshooting
If you encounter issues with your Kemot PROsinus-2600, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No power output from AC sockets | Inverter is OFF Battery low/disconnected Overload protection activated AC input not connected (in UPS mode) | Turn main ON/OFF switch ON and press OUTPUT & INVERTER ON/OFF. Check battery connections and charge level. Reduce connected load; reset circuit breaker. Connect AC input if UPS mode is desired. |
| Battery not charging | AC input not connected Charger current switch OFF or faulty Battery faulty | Ensure AC input is connected. Check charger current switch setting (10A/15A). Test battery condition. |
| Overload warning/shutdown | Connected load exceeds 1800W | Disconnect some appliances to reduce the load. Restart the inverter. |
| Unusual noise or smell | Internal fault Overheating | Immediately turn off the inverter and disconnect all power sources. Contact customer support. Ensure proper ventilation. |
If the problem persists after attempting these solutions, please contact Kemot customer support.
8. Specifications
Detailed technical specifications for the Kemot PROsinus-2600 inverter.
| Feature | Specification |
|---|---|
| Model | PROsinus-2600 (URZ3428B) |
| Rated Power | 1800 W |
| Battery Voltage | 24 V DC (max. 30 V DC) |
| Input Voltage Range (AC) | 190-260 V AC |
| Input Frequency | 45-60 Hz |
| Output Voltage Range (AC) | 230 V AC +/-5% (Inverter: 230 VAC +/-3%) |
| Output Frequency | 50/60 Hz +/-0.5 Hz |
| Output Waveform | Pure Sine Wave |
| Efficiency (DC to AC) | >=85% |
| Charge Current | 10 A / 15 A (selectable) |
| Recommended Battery Capacity | 50-300 Ah (200 Ah recommended) |
| Approx. Battery Charging Time | 4-14 hours (depending on battery capacity) |
| Transfer Time | <=4 ms |
| Protections | Overload, Short-circuit, Over-voltage, Under-voltage |
| Operating Temperature | 0-40 °C |
| Operating Humidity | 10-90% |
| Number of AC Outlets | 2 |

Figure 5: Representation of a Pure Sine Wave output.
9. Warranty & Support
The Kemot PROsinus-2600 comes with a 2-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims.

Figure 6: Product packaging highlighting features and warranty.
For technical support, warranty service, or any questions not covered in this manual, please contact your retailer or the official Kemot customer service. Contact information can typically be found on the product packaging or the manufacturer's website.