ACTIVA Volcano 3L

Activa Volcano Quick Water Heater Geyser

Instruction Manual

1. Introduction

Thank you for choosing the Activa 3 Liters Volcano Quick Water Heater Geyser. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new water heater. Please read this manual thoroughly before installation and use, and keep it for future reference.

This instant water heater is designed to provide hot water quickly and efficiently, featuring a 3-liter capacity, a 3 KVA ISI Copper Element, and a durable 0.8mm Anti Rust Coated 304L Pure Stainless Steel Tank. It includes an Auto Cut-Off function and an ABS Body, ensuring both performance and safety.

Activa Volcano Quick Water Heater Geyser

Figure 1: Activa Volcano Quick Water Heater Geyser

2. Safety Precautions

Your safety is paramount. Please adhere to the following precautions to prevent accidents and ensure proper functioning of the geyser:

  • Ensure water supply before turning on the geyser.
  • Do not install the geyser yourself. Installation must be performed by a skilled electrician or qualified technician.
  • There should be no inflammable material around the geyser.
  • Turn OFF the power supply when the geyser is not in use or during maintenance.
  • Read the manual carefully before installing the geyser.
  • Install the geyser at the appropriate height on the wall, ensuring it is securely mounted.
  • Always ensure the water heater is completely full with water before switching on the power supply. To ensure this, open the outlet and inlet valve fully until there are no air pockets or bubbles in the water flowing out of the outlet valve.
  • The hexagonal safety valve (pressure relief valve) fitted on the coupling on the inlet pipe will take care of any positive pressure exceeding 3.5 kg/cm² (50 p.s.i.) by opening and starting to drip. Do not block this valve.
  • If a hydro-pneumatic water pump supplies water or the head of feeding overhead tank exceeds 18 meters, a PRESSURE REDUCING VALVE is to be fitted in the inlet pipe to protect the water heater from excessive pressure.
Advanced Safety Features of Activa Water Heater

Figure 2: Advanced Safety Features

3. Setup and Installation

Installation of the Activa Volcano Quick Water Heater should be carried out by a qualified professional to ensure safety and proper functioning. Follow these general steps:

  1. Site Selection: Choose a suitable wall location, ensuring it is sturdy enough to support the geyser's weight when full of water. The location should be near water inlet/outlet points and a power source.
  2. Mounting: Securely mount the geyser to the wall using appropriate fasteners. Ensure it is level and at the recommended height.
  3. Water Connections: Connect the cold water inlet (usually blue) and hot water outlet (usually red) pipes to the corresponding ports on the geyser. Use appropriate plumbing fittings and ensure all connections are watertight.
  4. Filling the Tank: Before connecting to power, open the hot water tap in your sink or shower and then slowly open the cold water inlet valve to the geyser. Allow water to flow through the geyser until a steady stream of water comes out of the hot water tap, indicating the tank is full and all air has been purged. Close the hot water tap.
  5. Electrical Connection: Connect the geyser to a dedicated and properly grounded electrical outlet. Ensure the voltage and wattage match the product specifications.
Activa Water Heater heating water quickly

Figure 3: Heats water quickly for immediate use

4. Operating Instructions

Once the geyser is properly installed and filled with water, you can begin operation:

  1. Power On: Ensure the water heater is full of water (as per installation step 3.4). Then, switch on the main power supply to the geyser.
  2. Heating Indicator: The red indicator light will illuminate, signifying that the heating element is active and water is being heated.
  3. Automatic Cut-Off: Once the water temperature attains the preset value (maximum 75 degrees Celsius), the red indicator light will turn off, and the green indicator light will glow, indicating that the geyser has reached the desired temperature and the heating element has automatically cut off.
  4. Hot Water Usage: You can now open your hot water tap to access heated water.
  5. Continuous Operation: The geyser will automatically reheat water as needed to maintain the set temperature.
Activa Water Heater Rapid Heating

Figure 4: Rapid Heating Capability

5. Maintenance

Regular maintenance ensures the longevity and efficiency of your Activa water heater:

  • Cleaning: Periodically clean the exterior of the geyser with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Descaling: The geyser features anti-scaling properties. However, in areas with hard water, mineral deposits can accumulate over time. It is recommended to have the heating element and tank descaled by a qualified technician annually to maintain efficiency.
  • Safety Valve Check: Occasionally check the pressure relief valve for any blockages or leaks. If it drips excessively, consult a technician.
  • Power Off When Not in Use: For extended periods of non-use, it is advisable to turn off the power supply to the geyser.

6. Troubleshooting

If you encounter issues with your Activa water heater, refer to the table below for common problems and solutions. For complex issues, contact customer support.

ProblemPossible CauseSolution
No hot water / Geyser not turning onNo power supply; Thermal cut-out activated; Faulty heating element.Check power connection and circuit breaker. If thermal cut-out activates, it indicates a fault; contact service center.
Water not hot enoughInsufficient heating time; Mineral buildup.Ensure geyser is on for sufficient time. If problem persists, consider descaling by a technician.
Water dripping from safety valveNormal operation due to pressure build-up; Excessive water pressure.A small amount of dripping is normal. If excessive, install a pressure reducing valve in the inlet line (refer to Safety Precautions).
Unusual noise from geyserSediment buildup in tank.Contact a qualified technician for inspection and cleaning.

In the rare case of thermostat failure, the thermal cut-out provides protection against dry heating of the element and excessive heating. The company provides an inbuilt service alarm system which will alert as the thermostat fails. The movement of the alarm alerts you should immediately switch off the power supply connected to the geyser and call our Service Center through your dealer for thermostat calibration.

7. Specifications

Below are the key specifications for the Activa 3 Liters Volcano Quick Water Heater Geyser:

FeatureSpecification
BrandACTIVA
Model NumberVolcano 3L
Product Dimensions20W x 30H Centimeters
Wattage3000 Watts
Capacity3 Liters
Special FeaturesLightweight, Overheat Protection, Rustproof
ColourMulticolor
Maximum Temperature75 Degrees Celsius
EfficiencyEnergy Efficient
Mounting TypeWall
Tank Material0.8mm Anti Rust Coated 304L Pure Stainless Steel
Body MaterialABS Body
Item Weight3 kg 20 g
Country of OriginIndia
Activa Water Heater Dimensions

Figure 5: Product Dimensions (23 cm width, 40 cm height)

8. Warranty and Support

The Activa 3 Liters Volcano Quick Water Heater Geyser comes with a 5-year warranty. Please note the following terms regarding warranty and service:

  • Product installation is to be done by the customer himself or by a qualified technician at the customer's expense.
  • For warranty claims or any product-related issues, the customer will need to send the product to the service center for repair.
  • The product will be repaired only at our authorized service centers.

For further assistance, warranty claims, or any product-related issues, please contact the manufacturer:

Manufacturer: TECHVISION INTERNATIONAL PVT. LTD. INDIA
Email: info@activaappliances.com
Phone: 9999427599

Related Documents - Volcano 3L

Preview Activa Glow in the Dark 3.5CH RC Helicopter: User Manual and Flight Guide
Comprehensive user manual for the Activa Glow in the Dark 3.5CH RC Helicopter, covering setup, flight instructions, safety warnings, troubleshooting, and warranty information.
Preview Activa Wireless Earbuds with Dynamic Speakers - User Manual & Specifications
Comprehensive user manual for Activa Wireless Earbuds with Dynamic Speakers. Includes quick start guide, operation instructions, product specifications, charging details, and warranty information.
Preview Activa Ultra-Portable Air Cooler with Humidifier and Touch Display - User Manual
User manual for the Activa Ultra-Portable Air Cooler, featuring an atomizing humidifier and touch display. Includes detailed product specifications, limited lifetime warranty information, setup, operation, maintenance, and safety guidelines.
Preview Activa Magnetic Building Tiles User Manual
User manual for the Activa 100-Piece Magnetic Building Tiles Set, detailing introduction, magnetic tile usage, structure ideas, and limited lifetime warranty.
Preview Activa LED Night Light with Smart Sensor (6-Pack) - User Manual & Specifications
User manual and specifications for the Activa LED Night Light with Smart Sensor (6-Pack). Features automatic dusk-to-dawn operation, 6500K cool white light, and energy efficiency. Includes warranty information.
Preview Klear Action Tooth Whitening System User Guide - Activa
Official user guide for the Activa Klear Action Tooth Whitening System. Learn how to use the whitening light, gel, and rinse for effective teeth whitening. Includes instructions, safety warnings, troubleshooting, and tips for maintaining a bright smile.