1. Introduction
Thank you for choosing the ERICKHILL ER02 EMF Meter. This device is designed to detect and measure electromagnetic field (EF), magnetic field (MF), and radio frequency (RF) radiation. Equipped with an integrated electromagnetic radiation sensor, it provides accurate readings displayed on a clear LCD screen. This manual will guide you through the setup, operation, and maintenance of your ER02 meter to ensure optimal performance and accurate measurements.

Figure 1: ERICKHILL ER02 EMF Meter
The ERICKHILL ER02 EMF Meter is a compact, handheld device featuring a color LCD display and intuitive button controls for various measurement functions.
2. Product Overview
2.1. Package Contents
- 1 x ERICKHILL ER02 EMF Meter
- 1 x USB Charging Cable
- 1 x User Manual
Figure 2: ERICKHILL ER02 Package Contents
The package includes the ER02 meter, a USB charging cable for convenient power, and this user manual for detailed instructions.
2.2. Key Features
- Integrated electromagnetic radiation sensor for precise measurement.
- Measures Magnetic Field (MF) in mG / µT, Electric Field (EF) in V/m, and Radio Frequency (RF) in mW/m².
- Audible and visual alarm when readings exceed preset safety values.
- Data hold function for convenient recording.
- Average and Peak (Maximum) value display.
- LCD screen with switchable white/black display and measurement/graph interface.
- Low battery indicator and auto power-off function.
Figure 3: ERICKHILL ER02 Key Features
The ER02 offers a large, clear LCD, unit switching, average/max value modes, data hold, low battery indication, auto power off, and a sound alarm.
2.3. Display Layout
Figure 4: ERICKHILL ER02 Display Elements
The display provides comprehensive information for accurate readings.
- Average Value: Displays the average measurement.
- Alarm Symbol: Indicates when the alarm threshold is exceeded.
- Reading Display: Shows the current measurement value.
- Peak Value: Displays the highest recorded measurement.
- Auto Off Indicator: Shows if the auto power-off function is active.
- Audio Indicator: Indicates if the sound alarm is enabled.
- EF/MF/RF Testing Indicator: Shows the currently selected measurement mode (Electric Field, Magnetic Field, or Radio Frequency).
- Radiation Level Evaluation: A bar graph indicating the severity of the detected radiation.
- Testing Unit: Displays the unit of the current measurement (e.g., V/m, mG, mW/m²).
3. Setup
3.1. Charging the Device
The ERICKHILL ER02 EMF Meter comes with a built-in rechargeable Lithium-polymer battery. Before first use, or when the low battery indicator appears, charge the device using the provided USB charging cable. Connect the cable to the meter's charging port and to a standard USB power source (e.g., computer USB port, USB wall adapter).
3.2. Initial Power On
Press and hold the power button (usually labeled with a power symbol) to turn on the device. The LCD screen will light up, and the meter will enter its default measurement mode.
4. Operating Instructions
4.1. Power On/Off
- To Power On: Press and hold the HOLD button for approximately 2 seconds.
- To Power Off: Press and hold the HOLD button for approximately 2 seconds. The device also features an auto power-off function to conserve battery.
4.2. Measurement Modes (EF, MF, RF)
The ER02 can measure Electric Field (EF), Magnetic Field (MF), and Radio Frequency (RF) radiation. To switch between these modes:
- Press the MODE button to cycle through EF, MF, and RF measurement modes. The active mode will be indicated on the display (G. EF/MF/RF Testing Indicator).
Figure 5: 3-in-1 Measurement Capabilities
The ER02 provides distinct measurement ranges for RF, EF, and MF, with an effective range within 20cm of the source.
4.3. Unit Switching (for MF)
When in Magnetic Field (MF) mode, you can switch between milliGauss (mG) and microTesla (µT) units:
- Press the MG/UT button to toggle between mG and µT units.
4.4. Data Hold
To freeze the current reading on the display:
- Press the HOLD button briefly. The "HOLD" indicator (H) will appear on the screen.
- Press the HOLD button again to release the data hold and resume live measurements.
4.5. Alarm Function
The ER02 features an alarm that activates when measured values exceed predefined safety thresholds (0.4 µT (4 mG), 40 V/m, or 1 mW/m²).
- When the alarm is triggered, the buzzer will sound, and the display may change color or flash.
- To toggle the sound alarm on or off, press the SOUND button. This is useful in environments where an audible alarm might be disruptive.
4.6. Graph Mode
The ER02 offers a graph display mode to visualize changes in radiation levels over time.
- Short Press GRAPH: Switches between the standard measurement interface and the graph interface.
- Long Press GRAPH: Toggles the LCD display background between white and black for better visibility in different lighting conditions.
Figure 6: GRAPH Button Functionality
The GRAPH button allows switching between display modes and interface types for enhanced data visualization.
4.7. Average/Maximum Value
The meter can display either the average or the peak (maximum) value of the measurement.
- Press the AVG/MAX button to switch between displaying the average value (A) and the peak value (D). This is useful for observing fluctuations and identifying the highest radiation levels.
5. Applications
The ERICKHILL ER02 EMF Meter is a versatile tool for detecting electromagnetic radiation in various environments. Its primary applications include:
- Home Environment: Testing radiation from household appliances such as televisions, computers, microwave ovens, refrigerators, and mobile phones.
- Office Spaces: Checking radiation levels from printers, monitors, and other office equipment.
- Outdoor Areas: Detecting radiation from cellular towers and power lines.
- Personal Safety: Identifying potential sources of high electromagnetic exposure in your daily surroundings.
Figure 7: Radio Frequency Field Detection
The ER02 can detect RF radiation from devices like WiFi routers, Bluetooth devices, and other radio equipment.
Figure 8: Electric Field Detection
Use the ER02 to measure electric fields emitted by appliances such as microwave ovens.
Figure 9: Magnetic Field Detection
The meter is effective for detecting magnetic fields from devices like hair dryers, electric motors, fans, and wire compressors.
6. Maintenance
To ensure the longevity and accuracy of your ERICKHILL ER02 EMF Meter, follow these maintenance guidelines:
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the meter in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery: Recharge the battery regularly, even if the device is not in frequent use, to maintain battery health. Avoid fully discharging the battery for extended periods.
- Avoid Impact: Protect the device from drops and strong impacts, which can damage internal components.
7. Troubleshooting
If you encounter issues with your ERICKHILL ER02 EMF Meter, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Low battery or no charge. | Charge the device using the USB cable. Ensure the charging cable and power source are functional. |
| Readings are erratic or unstable. | Interference from other electronic devices; user's body acting as an antenna; device too close to strong sources. | Move away from other electronics. Ensure proper distance from the source being measured (recommended within 20cm). Hold the device steadily. |
| Alarm sounds continuously. | Measured value exceeds the preset alarm threshold. | This indicates high radiation. Move away from the source or identify the source. Press the SOUND button to mute the alarm if desired. |
| Display is dim or unreadable. | Low battery; display brightness setting; environmental lighting. | Charge the device. Long press the GRAPH button to switch between white and black display backgrounds for better contrast. |
| Buttons are unresponsive. | Temporary software glitch. | Try restarting the device by powering it off and on again. If the issue persists, contact customer support. |
8. Specifications
| Feature | Detail |
|---|---|
| Model Number | ER02 |
| Battery Type | 1 Lithium-polymer (included) |
| Product Dimensions (L x W x H) | 14 x 6.5 x 3.2 cm |
| Product Weight | 5 grams |
| Magnetic Field Unit | mG / µT |
| Electric Field Unit | V/m |
| Radio Frequency Unit | mW/m² |
| Effective Measurement Range | Within 20cm of the source |
9. Warranty and Support
ERICKHILL provides comprehensive after-sales service and technical support for the ER02 EMF Meter.
- Warranty: The product comes with a 36-month after-sales service period.
- Technical Support: Lifetime technical support is available for any questions or issues you may encounter.
If you have any questions or require assistance, please do not hesitate to contact ERICKHILL customer support. Refer to the contact information provided with your purchase or on the official ERICKHILL website.




