VONROC GP526AC / GP500

VONROC Automatic Garden Water Pump 1000W User Manual

Model: GP526AC / GP500 | Brand: VONROC

1. Introduction

Thank you for choosing the VONROC Automatic Garden Water Pump. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new pump. Please read this manual thoroughly before use and keep it for future reference.

2. Safety Information

Always adhere to basic safety precautions to reduce the risk of fire, electric shock, and personal injury. This pump is designed for pumping clear water and water with small impurities. Do not use it for flammable, corrosive, or explosive liquids.

3. Product Overview

The VONROC Automatic Garden Water Pump is a powerful self-priming centrifugal pump designed for various watering tasks. Its robust stainless steel casing ensures durability.

Key Features:

Components:

VONROC Automatic Garden Water Pump
Figure 3.1: Overall view of the VONROC Automatic Garden Water Pump, showcasing its compact design and stainless steel body.
Pressure Switch with Indicators
Figure 3.2: Close-up of the pressure switch, which controls the automatic operation of the pump. It includes indicators for power, failure, and pump status.
Pressure Gauge
Figure 3.3: Detailed view of the integrated pressure gauge, displaying the current system pressure in bar.
Pressure Adjustment Screw
Figure 3.4: Top view of the pressure adjustment screw, allowing fine-tuning of the pump's operating pressure.

4. Setup and Installation

Proper installation is crucial for the pump's performance and longevity. Ensure the pump is placed on a stable, level surface.

  1. Positioning: Place the pump as close as possible to the water source to minimize suction lift. Ensure adequate space for ventilation.
  2. Suction Line Connection: Connect a suitable suction hose (not included) to the pump's inlet. Ensure the suction line is airtight to prevent air ingress, which can cause the pump to lose prime. For non-clear water sources, an inline filter (not included) is recommended.
  3. Discharge Line Connection: Connect the discharge hose (not included) to the pump's outlet. The pump supports connection of 2 or 4 sprinklers depending on the type.
  4. Priming the Pump: Before first use, or if the pump has run dry, the pump must be primed. Fill the pump casing with water through the designated filling port until it overflows. This ensures the pump can create the necessary vacuum for suction.
  5. Electrical Connection: Plug the pump into a grounded electrical outlet. Ensure the power supply matches the pump's requirements (230V).
Water being drawn into the pump
Figure 4.1: Illustrates the pump drawing water from a source, emphasizing the suction line connection.
Water being discharged from the pump
Figure 4.2: Shows water being discharged from the pump, indicating the outlet connection for irrigation systems.

5. Operating Instructions

Once installed and primed, the pump is ready for operation.

  1. Starting the Pump: After priming and connecting to power, switch the pump ON. The pump will start automatically and build pressure.
  2. Automatic Operation: The integrated pressure switch will automatically turn the pump ON when water is drawn (e.g., a tap is opened or sprinkler system activates) and OFF when water flow stops and pressure builds up.
  3. Monitoring: Observe the pressure gauge to ensure the pump is operating within expected pressure ranges.
  4. Stopping the Pump: To stop the pump, simply close all water outlets. The pump will shut off automatically. For extended periods of non-use, disconnect the pump from the power supply.

6. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your pump.

7. Troubleshooting

This section addresses common issues you might encounter with your pump.

ProblemPossible CauseSolution
Pump does not start.No power supply; Thermal overload; Pressure switch issue.Check power connection and circuit breaker; Allow pump to cool down; Check pressure switch reset button.
Pump runs but no water flows.Pump not primed; Air leak in suction line; Suction line blocked; Water source empty.Prime the pump; Check all suction connections for airtight seal; Clear any blockages; Ensure water source is sufficient.
Pump cycles on and off frequently.Small leak in system; Pressure switch setting too sensitive.Check for leaks in pipes/fittings; Adjust pressure switch sensitivity (refer to Figure 3.4).
Pump is excessively noisy.Air in pump/suction line; Cavitation; Loose mounting.Re-prime the pump; Ensure adequate water supply; Securely mount the pump.

8. Specifications

Technical data for the VONROC Automatic Garden Water Pump.

SpecificationValue
BrandVONROC
Model NumberGP526AC / GP500
Power (Advertised)1000 W
Power (Rated)800 W
Voltage230 Volts
Maximum Flow Rate3500 Litres per hour
Maximum Head44 meters
Maximum Suction Depth8 meters
Dimensions (L x W x H)53 x 28 x 24 cm
Weight8 Kilograms
MaterialStainless Steel Casing
Protection ClassIPX4 (Splash-proof)

Note: Specifications are subject to change without notice for product improvement.

9. Warranty and Support

VONROC products are manufactured to high quality standards. In the unlikely event of a defect, please contact VONROC customer support for assistance. Keep your proof of purchase for warranty claims.

For further assistance, spare parts, or detailed technical inquiries, please visit the official VONROC website or contact their customer service department. You can find more information at www.vonroc.com.

Related Documents - GP526AC / GP500

Preview VONROC GP807AA Pump Pre-Filter: Installation, Safety, and Maintenance Guide
Detailed guide for the VONROC GP807AA Pump Pre-Filter, covering essential safety instructions, product specifications, step-by-step installation, maintenance procedures, and warranty information. Suitable for household water supply and garden irrigation.
Preview VONROC LB501AC Leaf Blower / Leaf Vacuum User Manual
Get the most out of your VONROC LB501AC Leaf Blower and Leaf Vacuum with this comprehensive user manual. Learn about assembly, operation, safety, and maintenance for efficient garden care.
Preview VONROC GT502AC Grass Trimmer User Manual and Safety Instructions
Comprehensive user manual and safety guide for the VONROC GT502AC Grass Trimmer, detailing assembly, operation, maintenance, and technical specifications for safe and effective use.
Preview VONROC Bardolino Ø300cm / Pisogne 300x300cm Parasol Assembly and Warranty Guide
Assembly instructions and warranty information for the VONROC Bardolino Ø300cm and Pisogne 300x300cm parasols (models GP501XX/GP506XX). Learn how to set up and care for your parasol.
Preview VONROC Parasol Bardolino Ø300CM / Pisogne 300x300CM User Manual
Comprehensive user manual for the VONROC Parasol Bardolino Ø300CM and Pisogne 300x300CM (models GP501XX/GP506XX). Includes assembly instructions, operation guide, safety warnings, and warranty information.
Preview VONROC LM502AC Electric Lawn Mower - User Manual and Safety Guide
Comprehensive user manual for the VONROC LM502AC Electric Lawn Mower, detailing safety instructions, assembly, operation, maintenance, and technical specifications for optimal garden care.