Southwire MC-PCS Duo Power and Control/Signal Cable
Southwire MC-PCS Duo Power and Control/Signal Cable User Manual
Model: MC-PCS Duo Power and Control/Signal Cable
1. Introduction
This manual provides essential information for the proper installation, use, and maintenance of the Southwire 12/2 Solid 16/2 Solid x 250 ft. MC-PCS Duo Power and Control/Signal Cable. Please read this manual thoroughly before beginning any work to ensure safe and effective operation.
The Southwire MC-PCS Duo cable is designed for combining power/lighting circuits with Class 2 or Class 3 signal or control circuits within a single cable assembly. This product meets the National Electrical Code (NEC) and UL listing requirements for such applications.
2. Important Safety Information
WARNING: Risk of Electric Shock. Installation should only be performed by qualified personnel in accordance with all applicable national and local electrical codes.
- Always disconnect power at the circuit breaker or fuse box before installing or servicing electrical wiring.
- Ensure all connections are secure and properly insulated to prevent short circuits and electrical hazards.
- Do not exceed the specified voltage and current ratings for this cable.
- Protect the cable from physical damage during and after installation.
- Wear appropriate personal protective equipment (PPE), including safety glasses and insulated gloves, when working with electrical systems.
- Consult local building codes and regulations for specific requirements regarding cable installation.
3. Product Overview
The Southwire MC-PCS Duo cable integrates both power and control/signal conductors within a single interlocked armor. This design simplifies installation and reduces the need for multiple cable runs.

Figure 1: Illustration of the Southwire MC-PCS Duo cable. The image displays a cross-section of the cable, revealing its metallic interlocked armor with a yellow stripe, and the internal conductors. Visible conductors include a blue, white, black, and green wire, indicating both power and control/signal components.
3.1 Key Features and Applications
- Integrated Design: Combines 12/2 Solid power conductors and 16/2 Solid control/signal conductors in one cable.
- Versatile Use: Suitable for branch power distribution in commercial, industrial, institutional, and multi-residential buildings.
- Lighting and Control: Ideal for power, lighting, control, and signal circuits, including luminary applications with 0-10V dimming in LED lighting systems.
- Installation Flexibility: Can be fished or embedded in plaster, and used in both concealed or exposed installations.
- Code Compliant: Meets NEC and UL listing requirements for combining different circuit types.
4. Installation Instructions
Follow these general guidelines for installing the Southwire MC-PCS Duo cable. Always refer to local electrical codes and the NEC for specific requirements.
4.1 Pre-Installation Checklist
- Verify that the cable type and size are appropriate for the intended application and load requirements.
- Ensure all necessary tools and connectors are available.
- Confirm that power to the installation area is safely disconnected.
4.2 Installation Steps
- Route the Cable: Carefully route the MC-PCS Duo cable along the intended path, ensuring it is protected from sharp edges, excessive bending, and potential damage.
- Secure the Cable: Secure the cable using appropriate straps, clamps, or hangers at intervals compliant with local codes and manufacturer recommendations.
- Terminate Conductors:
- Carefully strip the outer armor and insulation from the conductors at the termination points.
- Connect the 12/2 Solid power conductors (typically black, white, and bare ground) to the power circuit terminals.
- Connect the 16/2 Solid control/signal conductors (typically blue and green, or as per specific application) to the control or signal circuit terminals.
- Ensure all connections are tight and secure.
- Grounding: Ensure proper grounding of the cable armor and all connected equipment as required by code.
- Testing: After installation, perform continuity and insulation resistance tests to verify proper wiring and absence of faults before restoring power.
- Restore Power: Once all checks are complete and safe, restore power to the circuit.
5. Operating Principles
The Southwire MC-PCS Duo cable functions as a conduit for both electrical power and low-voltage control/signal transmissions. Once properly installed and connected to a power source and control devices, it facilitates the intended electrical and communication functions.
- Power Conductors: The 12/2 Solid conductors deliver electrical power to connected loads, such as lighting fixtures.
- Control/Signal Conductors: The 16/2 Solid conductors transmit low-voltage signals, commonly used for dimming controls (e.g., 0-10V dimming) or other control applications.
- Integrated Functionality: The cable's design allows for simultaneous power delivery and signal transmission, streamlining wiring for systems requiring both.
6. Maintenance
The Southwire MC-PCS Duo cable is designed for long-term reliability with minimal maintenance. However, periodic inspection is recommended to ensure continued safe operation.
- Visual Inspection: Periodically inspect exposed sections of the cable for any signs of physical damage, such as cuts, abrasions, or crushing.
- Connection Integrity: Ensure that all connections remain tight and free from corrosion.
- Environmental Protection: Verify that the cable is not exposed to conditions beyond its rated environmental specifications (e.g., extreme temperatures, excessive moisture) unless specifically designed for such environments.
- Cleaning: If necessary, clean the exterior of the cable with a dry cloth. Do not use harsh chemicals or abrasive materials.
7. Troubleshooting
This section addresses common issues that may arise during or after the installation of the MC-PCS Duo cable. Always ensure power is disconnected before attempting any troubleshooting steps involving live circuits.
| Problem | Possible Cause | Solution |
|---|---|---|
| No power to connected device. |
|
|
| Control/signal not functioning (e.g., dimming not working). |
|
|
| Cable overheating. |
|
|
If issues persist after following these steps, contact a qualified electrician or Southwire customer support.
8. Technical Specifications
| Attribute | Detail |
|---|---|
| Product Name | Southwire 12/2 Solid 16/2 Solid x 250 ft. MC-PCS Duo Power and Control/Signal Cable |
| Model | MC-PCS Duo Power and Control/Signal Cable |
| Brand | Southwire |
| ASIN | B0B6WLFYL2 |
| Power Conductors | 12 AWG Solid (2 conductors + ground) |
| Control/Signal Conductors | 16 AWG Solid (2 conductors) |
| Length | 250 ft. |
| Material | Copper conductors, Metallic Interlocked Armor |
| Color | Yellow (stripe on armor) |
| Voltage Rating | 600 Volts (DC) |
| Compliance | NEC, UL Listed |
| Package Dimensions | 18 x 18 x 8 inches |
| Package Weight | 35.8 Pounds |
9. Warranty and Support
For specific warranty information regarding your Southwire MC-PCS Duo cable, please refer to the official Southwire website or contact Southwire customer service directly. Southwire stands behind the quality and performance of its products.
Manufacturer: Southwire
Contact Information: For technical support, product inquiries, or warranty claims, please visit the Southwire Store on Amazon or the official Southwire corporate website.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.