Introduction
This manual provides instructions for the safe installation, operation, and maintenance of your YYJLX Crystal Semi Flush Mount Ceiling Light Fixture, Model Y-1147. Please read this manual thoroughly before installation and retain it for future reference.

Image: The YYJLX Crystal Semi Flush Mount Ceiling Light Fixture in Gold Small.
Safety Information
- Always turn off the power supply at the main circuit breaker before beginning installation or performing any maintenance.
- Consult a qualified electrician if you are unsure about the installation process.
- Ensure all electrical connections are secure and comply with local codes and ordinances.
- Do not exceed the maximum wattage specified for the bulb (60 watts).
- Handle crystal components with care to prevent breakage.
- This fixture is designed for indoor use only.
Package Contents
Please verify that all components are present before beginning installation.
- YYJLX Crystal Semi Flush Mount Ceiling Light Fixture
- Mounting Hardware
Note: Bulb is not included.
Specifications

Image: Dimensions and electrical parameters of the light fixture.
| Feature | Detail |
|---|---|
| Brand | YYJLX |
| Model Number | Y-1147 |
| Color | Gold |
| Material | Metal, Crystal |
| Style | Modern |
| Light Fixture Form | Ceiling |
| Room Type | Bathroom, Bedroom, Dining Room, Entryway, Hallway, Living Room, Lobby, Study Room |
| Specific Uses | Indoor use only |
| Power Source | Corded Electric |
| Special Features | Dimmable (with compatible bulb/switch) |
| Control Method | Remote (with compatible bulb/switch) |
| Light Source | LED (compatible) |
| Number of Light Sources | 1 |
| Voltage | 110 Volts |
| Light Color | Warm White (with appropriate bulb) |
| Embellishment Feature | Crystal |
| Lighting Method | Downlight |
| Max Wattage | 60 watts |
| Bulb Base | E26 |
| Switch Type | Touch (with compatible switch) |
| Water Resistance Level | Not Water Resistant |
| Connectivity Protocol | RF or IR (with compatible bulb/switch) |
| Brightness | 800 lumen (with appropriate bulb) |
| Efficiency | 13.33 lumens per watt (with appropriate bulb) |
| Mounting Type | Ceiling Mount |
| Fixture Type | Non Removable |
| Color Temperature | 2700 Kelvin (with appropriate bulb) |
| Installation Type | Semi Flush Mount, Flush Mount |
| Required Assembly | Yes |
| Item Dimensions (L x W x H) | 7.48"L x 7.48"W x 7.08"H |
| Item Weight | 2.31 Pounds |
Setup and Installation
Before You Begin
Turn off power at the circuit breaker. Ensure you have all necessary tools (screwdriver, wire strippers, electrical tape, etc.) and the included mounting hardware.
Installation Steps
- Prepare the Mounting Surface: Ensure the electrical box is securely mounted and capable of supporting the fixture's weight.
- Connect Wiring: Connect the fixture's wires to the corresponding household wires (black to black, white to white, ground to ground). Secure connections with wire nuts and electrical tape.
- Attach Mounting Plate: Secure the fixture's mounting plate to the electrical box using the provided screws.
- Install Fixture Body: Carefully align the fixture body with the mounting plate and secure it with the decorative nuts or screws.
- Install Bulb: Screw an E26 base bulb (max 60W, not included) into the socket.
- Restore Power: Turn the power back on at the circuit breaker and test the light fixture.
Video: Official installation guide for the YYJLX Crystal Semi Flush Mount Ceiling Light Fixture. This video demonstrates the steps for wiring and mounting the fixture to the ceiling.

Image: Detailed view of the fixture's components, including the crystal pendant, iron top plate, and E26 lamp head.
Operating Instructions
Once installed, operate your YYJLX Crystal Semi Flush Mount Ceiling Light Fixture using a standard wall switch. If using a dimmable E26 bulb and a compatible dimmer switch (both not included), you can adjust the light intensity to your preference.

Image: Illustration of E26 dimmable bulb compatibility.
Maintenance
- Cleaning: To clean the fixture, ensure the power is off. Wipe the metal parts with a soft, dry cloth. For the crystal components, use a soft, damp cloth with a mild glass cleaner, then dry immediately with a clean, lint-free cloth.
- Bulb Replacement: Always turn off the power before replacing the bulb. Allow the bulb to cool completely. Unscrew the old bulb and screw in a new E26 base bulb (max 60W).
- Inspection: Periodically check all connections and mounting hardware for tightness.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on | No power supply | Check circuit breaker and wall switch. |
| Loose wiring connection | Turn off power, check and secure all wiring connections. | |
| Faulty bulb | Replace the bulb with a new E26 bulb (max 60W). | |
| Light flickers | Loose bulb or wiring | Turn off power, tighten the bulb, and check wiring connections. |
| Incompatible dimmer switch/bulb | Ensure both the bulb and dimmer switch are compatible with each other and the fixture. | |
| Crystals appear dull | Dust or residue buildup | Clean crystals as per maintenance instructions. |
Warranty and Support
YYJLX light fixtures come with after-sales support that covers defects in materials and workmanship. For specific warranty details or to initiate a claim, please contact YYJLX customer service directly.
Return Policy: This product is eligible for return within 30 days of purchase, subject to the retailer's return policy.