Tektronix MSO22 2-BW-100

Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope

User Manual

Introduction

This manual provides essential information for the safe and efficient operation of your Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope. This instrument is designed for precise measurement and analysis of electronic signals, featuring a 100 MHz bandwidth and 2 analog channels.

Key features include:

  • Analog input channels: 2 inputs
  • Bandwidth: 100 MHz
  • Sample rate: 2.5 GS/s Half channels; 1.25 GS/s All channels
  • Record length: 10 Mpoints per channel
  • Vertical resolution: 8 bits ADC; Up to 16 bits in high-resolution mode

Setup and Connections

Before operating the oscilloscope, ensure it is placed on a stable, level surface with adequate ventilation. Connect the power cord to the instrument and a grounded AC outlet.

Front view of the Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope

Figure 1: Front panel of the Tektronix MSO22 2-BW-100 Oscilloscope, showing the display, control knobs, buttons, and input connectors (Inputs 1, 2, Aux In, AFG/Aux Out).

Input Connections

  • Analog Inputs (1, 2): Connect your probes to these BNC connectors for signal acquisition.
  • Aux In: Auxiliary input for external trigger or other signals.
  • AFG/Aux Out: Output for the Arbitrary Function Generator or auxiliary signals.

Power On

Press the power button located on the front panel to turn on the instrument. Allow a few moments for the system to boot up.

Operating Instructions

This section outlines the basic steps for operating the oscilloscope to capture and analyze waveforms.

Basic Waveform Capture

  1. Connect Probe: Attach a compensated probe to one of the analog input channels (e.g., Input 1).
  2. Connect to Circuit: Connect the probe tip to the test point in your circuit and the ground clip to the circuit's ground.
  3. Auto-Set: Press the Auto-Set button (if available, common on oscilloscopes) to automatically adjust vertical and horizontal settings for a stable display.
  4. Adjust Vertical Scale: Use the Vertical Scale knob to adjust the volts per division, controlling the amplitude of the waveform on the screen.
  5. Adjust Horizontal Scale: Use the Horizontal Scale knob to adjust the seconds per division, controlling the time base of the waveform.
  6. Adjust Trigger: Use the Trigger Level knob to set the voltage level at which the oscilloscope captures the waveform, ensuring a stable display.

Measurement Functions

The MSO22 2-BW-100 offers various automated measurement functions. Access these through the on-screen menu system. Common measurements include Peak-to-Peak Voltage, Frequency, Period, and Rise/Fall Time.

Maintenance

Proper maintenance ensures the longevity and accuracy of your oscilloscope.

Cleaning

  • Wipe the exterior surfaces with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Ensure no liquid enters the instrument.
  • Clean the display screen with a soft, lint-free cloth specifically designed for electronic displays.

Calibration

For optimal performance, periodic calibration by qualified service personnel is recommended. Refer to the official Tektronix service manual for calibration procedures and intervals.

Troubleshooting

This section provides solutions to common issues you might encounter.

  • No Display:
    • Ensure the power cord is securely connected and the instrument is powered on.
    • Check the brightness and contrast settings of the display.
  • Unstable Waveform:
    • Adjust the trigger level and trigger source settings.
    • Verify the probe compensation is correct.
    • Check for proper grounding of the probe and the circuit under test.
  • No Signal Detected:
    • Ensure the probe is correctly connected to the input channel and the circuit.
    • Check the input coupling (AC/DC/GND) and vertical scale settings.
    • Verify the signal source is active.

If problems persist, contact Tektronix customer support.

Specifications

Detailed technical specifications for the Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope.

FeatureSpecification
Model NumberMSO22 2-BW-100
Analog Input Channels2 inputs
Bandwidth100 MHz
Sample Rate (Half Channels)2.5 GS/s
Sample Rate (All Channels)1.25 GS/s
Record Length10 Mpoints per channel
Vertical Resolution8 bits ADC; Up to 16 bits in high-resolution mode
ManufacturerTektronix
Date First AvailableJune 17, 2022

Warranty and Support

Tektronix products are designed for reliability and performance. For information regarding product warranty, please refer to the warranty statement included with your purchase or visit the official Tektronix website.

For technical support, service, or additional documentation, please contact Tektronix customer service or visit their official support portal. Ensure you have your product model number (MSO22 2-BW-100) and serial number ready when contacting support.

Online Resources: www.tek.com

© 2024 Tektronix. All rights reserved.