FRESHLIANCE Fresh Tag 1D

Freshliance Fresh Tag 1D Single Use Temperature Data Logger User Manual

Model: Fresh Tag 1D

1. Product Overview

The Freshliance Fresh Tag 1D is a single-use USB temperature data logger designed for monitoring temperature during cold chain transportation and storage. It features an LCD display for real-time data viewing and automatically generates PDF and CSV reports upon connection to a computer.

What's in the Box:

  • 1 x Fresh Tag 1D Data Logger
  • 1 x User Manual
  • 1 x Box
Freshliance Fresh Tag 1D Single Use Temperature Data Logger with LCD display.

Image: Freshliance Fresh Tag 1D Data Logger

2. Setup and Activation

The Fresh Tag 1D data logger comes pre-programmed with factory default parameters. No software installation is required for initial setup or report generation.

Starting the Data Logger:

  1. Locate the 'Start/Stop' button on the data logger.
  2. Press and hold the 'Start/Stop' button for approximately 5 seconds until the LCD screen displays relevant information, indicating that recording has begun.
  3. The default start delay is 10 minutes, and the recording interval is 5 minutes.
Image showing step 1 of using the data logger: pressing the START button.

Image: Pressing the Start Button to Activate

3. Operation

Monitoring Temperature:

Once activated, place the data logger with the items you wish to monitor. The logger will continuously record temperature data for its specified duration (e.g., 7 days, 30 days, 120 days, 180 days, 240 days depending on the model).

Freshliance Fresh Tag 1D showing temperature range from -22°F to 158°F and logging durations from 7 to 240 days.

Image: Temperature Data Logger Monitoring Range

LCD Screen Indications:

The LCD screen provides real-time information. A short press of the 'Start/Stop' button cycles through different display modes:

  • Current Temperature: Displays the immediate temperature reading.
  • Max/Min/Average Values: Shows the maximum, minimum, and average temperatures recorded during the logging period.
  • High/Low Alarm: Indicates if temperature thresholds have been exceeded.
  • Battery Level: Displays the remaining battery life in days.
Image illustrating various LCD indications on the Freshliance Fresh Tag 1D, including normal record, temperature alarm, maximum, minimum, and average temperatures.

Image: LCD Indication Instructions

Stopping the Data Logger:

To stop recording, press and hold the 'Start/Stop' button for 5 seconds until the screen indicates that logging has ceased.

Generating Reports:

After recording is complete, plug the data logger directly into a computer's USB port. The device will automatically generate PDF and CSV reports. No special software is required.

  • The PDF report provides a graphical summary and detailed temperature data.
  • The CSV report offers raw data for further analysis.
  • Reports include both Fahrenheit (℉) and Celsius (℃) temperature units.
Laptop screen showing an automatically generated PDF and CSV report from the Freshliance Fresh Tag 1D data logger.

Image: Auto-generated PDF & CSV Reports

Video: Freshliance Single Use Temperature Data Logger Overview

Video: This video demonstrates the features and basic operation of the Freshliance Single Use Temperature Data Logger, including its LCD display and report generation capabilities.

4. Maintenance

Battery:

The Fresh Tag 1D uses a built-in CR2 battery (included). As a single-use device, the battery is not user-replaceable. The battery life supports logging durations up to 240 days, depending on the specific model.

Storage:

Store the data logger in a cool, dry place away from direct sunlight and extreme temperatures when not in use. Ensure the device is kept within its specified operating and storage temperature ranges to maintain accuracy and battery integrity.

5. Troubleshooting

If you encounter issues with your Freshliance Fresh Tag 1D data logger, consider the following:

  • Logger Not Starting: Ensure you press and hold the 'Start/Stop' button for the full 5 seconds until the display activates.
  • No Report Generation: Verify that the logger is fully inserted into a functional USB port on your computer. Try a different USB port or computer if necessary. Ensure the logging period has concluded.
  • Inaccurate Readings: Confirm the logger was placed correctly within the environment to be monitored and that its operating range was not exceeded.
  • LCD Display Issues: If the display is blank or unreadable, the battery may be depleted, or the device may be damaged.

For persistent issues, please refer to the support information in Section 7.

6. Specifications

FeatureDetail
Model NameFresh Tag 1D
Temperature Range-22℉ to 158℉ (-30℃ to 70℃)
Temperature Accuracy±0.9℉ (±0.5℃)
Memory CapacityMax. 30,000 readings
Battery LifeUp to 240 days (depending on model)
Display TypeLCD
ConnectivityUSB
Waterproof GradeIP67
Dimensions3.39 x 1.97 x 0.16 inches
Weight3.53 ounces
Power Source1 CR2 battery (included)
Freshliance Fresh Tag 1D data logger with dimensions, temperature range, accuracy, and memory capacity details.

Image: Fresh Tag 1D Dimensions and Key Specifications

7. Certifications and Compliance

The Freshliance Fresh Tag 1D data logger complies with various international standards:

  • CE
  • RoHS
  • EN12830
  • ISO9001
  • FDA
  • FC
Certificates and compliance logos including ISO9001, CE, FDA, FC, RoHS, and EN12830 for Freshliance Fresh Tag 1D.

Image: Product Certifications

8. Warranty and Support

Freshliance provides technical support for its products. For assistance with your Fresh Tag 1D data logger, including troubleshooting or operational questions, please contact Freshliance customer service via email or phone. Specific warranty details may vary; please refer to your purchase documentation for more information.

For further information or support, please visit the official Freshliance website or contact their customer service department.

© 2023 FRESHLIANCE. All rights reserved.

Related Documents - Fresh Tag 1D

Preview COEUS-WiFi Real Time Temperature and Humidity Data Logger User Manual
User manual for the Freshliance COEUS-WiFi Real Time Temperature and Humidity Data Logger. Provides detailed instructions on setup, operation via the FreshLink mobile app and cloud platform, technical specifications, and device management.
Preview BlueTag TH20 Bluetooth Temperature and Humidity Data Logger User Manual
User manual for the BlueTag TH20, an intelligent Bluetooth temperature and humidity data logger. Learn about its features, specifications, operation, app usage, and troubleshooting.
Preview Freshliance G100-S + BlueTag Series Data Loggers User Manual
Comprehensive user manual for Freshliance G100-S Gateway and BlueTag Series Data Loggers, covering setup, operation, mobile app, cloud platform, and technical specifications for real-time temperature and humidity monitoring.
Preview Freshliance BlueTag A100 Audible and Visual Alarm User Manual
User manual for the Freshliance BlueTag A100 Bluetooth Audible and Visual Alarm. Learn about its product description, appearance, technical specifications, installation, and operation for detecting alarm messages from Freshliance Bluetooth data loggers.
Preview BlueTag T10/TH10 Bluetooth Temperature Data Loggers User Manual
User manual for Freshliance BlueTag T10/TH10 Bluetooth Temperature Data Loggers, detailing setup, operation, data management, app settings, technical parameters, and FCC compliance information.
Preview Freshliance BlueTag TH20 Temperature and Humidity Data Logger - Technical Specifications
Detailed specifications and features of the Freshliance BlueTag TH20, a reusable temperature and humidity data logger for cold chain and environmental monitoring. Features high accuracy, large storage, Bluetooth connectivity, and customizable settings.

Ask a question about this manual