LYCEBELL LC-856A

LYCEBELL LC-856A Pro Anemometer User Manual

Model: LC-856A

1. Introduction

The LYCEBELL LC-856A Pro Anemometer is a professional instrument designed for accurate measurement of wind speed, wind velocity, airflow (CFM), and temperature. It is suitable for various applications including HVAC system balancing, environmental monitoring, sailing, drone operation, and fishing. This manual provides detailed instructions for the proper use, setup, and maintenance of your device.

LYCEBELL LC-856A Pro Anemometer with detachable wind sensor, USB cable, and protective carrying case.

Figure 1: LYCEBELL LC-856A Pro Anemometer and accessories.

2. Package Contents

Please verify that all items listed below are included in your package:

Person carrying the durable hard shell protective suitcase designed for the LYCEBELL LC-856A Pro Anemometer.

Figure 2: Protective carrying case for the anemometer.

3. Product Features

The LC-856A Pro Anemometer offers the following key features:

4. Component Identification

Familiarize yourself with the main components and controls of your anemometer:

Diagram of the LYCEBELL LC-856A Pro Anemometer's control panel, detailing each button's function.

Figure 3: Anemometer button functions.

  1. Backlight LCD
  2. MAX/MIN Mode Button
  3. Wind Speed / Air Volume Button
  4. HOLD Button (Hold current reading)
  5. Units Switchable Button
  6. °C/°F Switchable Button
  7. REC Button (Record measurement)
  8. Input Sampling Cross-Sectional Area Button
  9. POWER ON/OFF Button
  10. Default Record Button
  11. Backlight ON/OFF Button
  12. Confirm Input Area Button
  13. Average Airflow Measurement Button
  14. Read Record Data Button
LYCEBELL LC-856A Pro Anemometer displaying its dimensions and the clarity of its backlit LCD screen in various lighting conditions.

Figure 4: Anemometer dimensions and backlit LCD.

5. Setup

5.1 Battery Installation

The LC-856A Anemometer requires one 9V (6F22) battery. To install or replace the battery:

  1. Locate the battery compartment cover on the back of the device.
  2. Use the provided screwdriver to loosen the screw on the battery cover.
  3. Remove the cover and insert a new 9V battery, ensuring correct polarity.
  4. Replace the battery cover and tighten the screw.
Internal view of the LYCEBELL LC-856A Pro Anemometer's battery compartment and its extensible, replaceable wind sensor.

Figure 5: Battery compartment and extensible wind sensor.

5.2 Connecting the Wind Sensor

The wind sensor connects to the main unit via a coiled cable. Align the connector and push it firmly into the port on the top side of the anemometer. The sensor is extensible, allowing for flexible positioning during measurements.

6. Operating Instructions

6.1 Power ON/OFF

Press the POWER ON/OFF button (9) to turn the device on or off.

6.2 Basic Wind Speed Measurement

Once powered on, the device will automatically begin measuring wind speed and temperature. Position the wind sensor in the airflow you wish to measure. The readings will be displayed on the LCD.

LYCEBELL LC-856A Pro Anemometer in use for HVAC system air balancing and general air flow measurement.

Figure 6: Anemometer in use for HVAC and general airflow.

6.3 Unit Selection

Press the Units Switchable button (5) to cycle through different wind speed units: m/s, km/h, ft/min, knots, and mph. Press the °C/°F Switchable button (6) to switch between Celsius and Fahrenheit for temperature readings.

6.4 Data Hold

During measurement, press the HOLD button (4) to freeze the current data on the display. Press it again to return to normal measurement mode.

6.5 Backlight

Press the Backlight ON/OFF button (11) to toggle the LCD backlight on or off, improving visibility in low-light conditions.

6.6 Air Volume (CFM) Measurement

To measure air volume, you need to input the cross-sectional area of the duct or opening. Press the Input Sampling Cross-Sectional Area button (8) and follow the on-screen prompts to enter the area. Then, press the Confirm Input Area button (12). The device will then calculate and display the air volume (CFM or CMM).

Hand holding the LYCEBELL LC-856A Pro Anemometer, illustrating its air volume measurement capabilities and specifications.

Figure 7: Air volume measurement range and specifications.

6.7 Data Logging and PC Connection

The LC-856A can store up to 600 sets of data. To record a measurement, press the REC button (7). To read stored data, press the Read Record Data button (14).

For advanced data logging and real-time monitoring, connect the anemometer to your PC using the provided USB cable. Install the accompanying PC software (refer to the software's specific instructions for installation and use). This allows for detailed analysis and graphical display of wind data.

LYCEBELL LC-856A Pro Anemometer connected to a PC via USB for data logging and analysis.

Figure 8: Anemometer connected to a PC for data transfer.

7. Specifications

ParameterValue
Wind Velocity Range0.03 ~ 100 mph
Wind Velocity Accuracy± 3.0% + 0.2 reading
Wind Speed Unitsm/s, km/h, ft/min, knots, mph
Wind Temperature Range14°F ~ 140°F ( -10°C ~ 60°C)
Temperature Units°C / °F
Wind Volume Range0 ~ 999,900 m³/min; 0 ~ 999,900 ft³/min
Data StorageUp to 600 records
ConnectivityUSB to PC
Power Supply1 x 9V (6F22) Battery
Product Dimensions16.3 x 8.5 x 3.45 cm
Item Weight320 g
MaterialPolycarbonate (PC)

8. Maintenance

8.1 Cleaning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the wind sensor is free from dust and debris for accurate readings.

8.2 Battery Replacement

Replace the 9V battery when the low battery indicator appears on the LCD. Refer to Section 5.1 for battery installation instructions. Remove the battery if the device will not be used for an extended period to prevent leakage.

8.3 Storage

Store the anemometer in its protective carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.

9. Troubleshooting

10. Warranty and Support

The LYCEBELL LC-856A Pro Anemometer is supported by the LYCEBELL after-sales service team. If you have any questions or require assistance with your product, please contact us. Our team is available to provide support within 24 hours.

Related Documents - LC-856A

Preview LYCEBELL LC-7200B DC/AC True-RMS Clamp Multimeter Operation Manual
User manual for the LYCEBELL LC-7200B DC/AC True-RMS Clamp Multimeter. Provides detailed operating instructions, safety guidelines, technical specifications, and usage for measuring voltage, current, resistance, capacitance, frequency, temperature, and NCV.
Preview LC-881W WBGT Anemometer Manual: Wind Speed, Temp, Humidity Measurement
Official operation manual for the LC-881W WBGT anemometer. Learn how to use this 3-in-1 handheld meter to measure wind speed, temperature, humidity, and WBGT for heat stress monitoring in outdoor and industrial applications.
Preview Sharp AQUOS Liquid Crystal Television Operation Manual
Comprehensive operation manual for Sharp AQUOS Liquid Crystal Televisions, covering safety, setup, operation, and troubleshooting for various models.
Preview SHARP LC-42LE756/758/759/760/761/762 & LC-50LE756/758/759/760/761/762 Series LCD Colour Television User Manual
Comprehensive user manual for SHARP LC-42LE and LC-50LE series LCD Colour Televisions, covering setup, operation, features, safety, troubleshooting, and technical specifications.
Preview Sharp AQUOS LCD TV Operation Manual - Setup, Features, and Specifications
Comprehensive operation manual for Sharp AQUOS Liquid Crystal Televisions, covering initial setup, remote control functions, picture and sound settings, smart TV features, internet connectivity, troubleshooting, and technical specifications for various models.
Preview Sharp LC-60/70LE Series LCD TV Service Manual
Official service manual for Sharp LC-60/70LE series LCD televisions (models LC-60/70LE650U, C6500U, LE657U, LE755U, LE757U, LE857U, C7500U). Provides technical specifications, repair procedures, troubleshooting guides, parts lists, and wiring diagrams for service professionals.