Introduction
This user manual provides essential information for the safe and effective operation of your Urion Blood Pressure Monitor. Please read this manual thoroughly before first use and retain it for future reference.
The Urion Blood Pressure Monitor is an automatic upper arm blood pressure machine designed for home use. It features an extra-large backlit LCD screen, two-user memory, and comes with both standard and extra-large cuffs to accommodate various arm sizes.
Package Contents
Verify that all items listed below are present in your package:
- 1x Urion Blood Pressure Monitor (Model: U80AH)
- 1x Standard Size Cuff (9"-17" / 22-42cm)
- 1x Extra Large Cuff (13"-21" / 32-52cm)
- 1x Nylon Carry Bag
- 1x Type-C USB Cable
- 4x AAA Batteries
- 1x User Manual

Image: All components included in the Urion Blood Pressure Monitor package, showing the main unit, two cuffs, a carry bag, USB cable, AAA batteries, and the instruction manual.
Product Features
- Extra Large Backlit LCD Screen: 6.0-inch display for clear and easy reading, especially in low light conditions.
- Two Cuff Sizes Included: Standard (9"-17") and Extra Large (13"-21") for a wide range of arm circumferences.
- One-Touch Operation: Simple start button for automatic measurement of systolic, diastolic, and pulse.
- Two User Memory: Stores up to 1000 readings (500 per user) with date and time stamps.
- Dual Power Options: Can be powered by 4x AAA batteries (included) or a Type-C USB cable (included).
- Advanced Accuracy: Utilizes new AVG algorithms for reliable measurements.
- Automatic Shut-off: Powers off after 3 minutes of inactivity to conserve battery life.

Image: The Urion Blood Pressure Monitor displaying blood pressure readings and pulse rate on its large, backlit LCD screen.

Image: The two included cuffs, demonstrating their fit on different arm sizes (medium/large and extra-large).

Image: The back of the monitor showing the battery compartment for four AAA batteries and the side view revealing the Type-C USB port for power.
Setup
1. Power Supply Installation
The monitor can be powered by either AAA batteries or a Type-C USB cable.
Using Batteries:
- Open the battery compartment cover on the back of the monitor.
- Insert 4 AAA batteries, ensuring correct polarity (+/-).
- Close the battery compartment cover securely.
Using USB Cable:
- Connect the Type-C end of the USB cable to the port on the side of the monitor.
- Connect the other end of the USB cable to a compatible USB power adapter (not included) or a computer USB port.
2. Cuff Connection
- Select the appropriate cuff size for your arm (Standard: 9"-17", Extra Large: 13"-21").
- Insert the air tube connector from the cuff firmly into the air socket on the side of the monitor.

Image: Detailed view of the monitor's air socket for cuff connection and the Type-C USB port.
3. Setting Date and Time
Before first use, it is recommended to set the correct date and time for accurate record-keeping.
- With the monitor off, press and hold the SET button for a few seconds until the year starts flashing.
- Press the MEM button to adjust the year. Press SET to confirm and move to the next setting (month, day, hour, minute).
- Repeat the process using MEM to adjust and SET to confirm for each value.
- Once all settings are confirmed, the monitor will exit setup mode.
Operating Instructions
1. Before Measurement
- Avoid eating, drinking alcohol, smoking, exercising, or bathing for 30 minutes before measurement.
- Rest for at least 5 minutes before taking a reading.
- Sit in a comfortable position with your back supported and feet flat on the floor.
- Place your arm on a flat surface so the cuff is at heart level.
2. Applying the Arm Cuff
- Slide your arm through the cuff loop. The air tube should run down the inside of your arm.
- Position the cuff so the bottom edge is approximately 2-3 cm (0.8-1.2 inches) above your elbow joint.
- Wrap the cuff snugly around your upper arm, ensuring it is not too tight or too loose. The fabric fastener should be secure.

Image: Step-by-step visual guide on how to correctly position and secure the arm cuff for measurement.
3. Taking a Measurement
- Select the desired user profile by pressing the user icon button (two person icons).
- Press the START/STOP button. The cuff will automatically inflate and then slowly deflate.
- Remain still and do not talk during the measurement process.
- Once the measurement is complete, your systolic pressure, diastolic pressure, and pulse rate will be displayed on the screen.
- The reading will automatically be saved to the selected user's memory.
- Press START/STOP again to turn off the monitor, or it will automatically shut off after 3 minutes.
4. Reviewing Memory Records
- With the monitor off, press the MEM button.
- The most recent reading will be displayed.
- Press the MEM button repeatedly to scroll through previous readings for the currently selected user.
- To switch between user memories, press the user icon button (two person icons) before entering memory mode or while in memory mode.
Maintenance
Cleaning:
- Wipe the monitor and cuff with a soft, dry cloth.
- Do not use abrasive cleaners or immerse the unit in water.
Storage:
- Store the monitor and cuff in the provided nylon carry bag.
- Keep in a cool, dry place away from direct sunlight and extreme temperatures.
- If not in use for an extended period, remove the batteries to prevent leakage.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Monitor does not turn on. | Batteries are dead or incorrectly inserted; USB cable not connected. | Replace batteries, check polarity, or connect USB cable securely. |
| Error message displayed. | Cuff not applied correctly; movement during measurement; irregular heartbeat detected. | Reapply cuff, remain still, consult a healthcare professional if irregular heartbeat persists. |
| Inconsistent readings. | Improper cuff placement; not resting before measurement; external factors (stress, time of day). | Ensure correct cuff placement and arm position. Rest for 5 minutes before measuring. Take multiple readings at different times. |
| Cuff does not inflate or inflates too little. | Air tube disconnected; air leakage from cuff. | Check that the air tube is securely connected to the monitor and cuff. Inspect cuff for damage. |
Specifications
- Model: U80AH
- Measurement Method: Oscillometric
- Measurement Range: Pressure: 0-299 mmHg; Pulse: 40-199 beats/minute
- Accuracy: Pressure: ±3 mmHg; Pulse: ±5% of reading
- Memory: 2 users, 500 readings each (total 1000)
- Cuff Size Range: Standard: 9"-17" (22-42cm); Extra Large: 13"-21" (32-52cm)
- Power Source: 4x AAA batteries or Type-C USB 5V
- Product Dimensions: 5"L x 3"W x 4"Th
- Weight: 1.52 Pounds (approx.)
Warranty and Support
For warranty information and customer support, please refer to the contact details provided on the product packaging or visit the official Urion website. Keep your purchase receipt as proof of purchase.
Legal Disclaimer: Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition. This device is intended for general health monitoring and should not replace professional medical advice.