1. Safety Information

Read this manual carefully before installation, operation, or maintenance. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage. Keep this manual for future reference.

  • Always disconnect the pump from the power supply before performing any work on it.
  • Ensure the electrical installation complies with local and national regulations.
  • The pump is designed for pumping clear water. Do not use it for flammable, corrosive, or explosive liquids.
  • Do not operate the pump dry. Ensure it is fully submerged before starting.
  • Use only the provided control box and ensure it is installed in a dry, protected location.
  • Secure the pump with a safety rope during installation and removal to prevent it from falling into the well.

2. Product Overview

The EBERTH 4-inch deep well submersible pump is a robust and efficient solution for extracting groundwater. Constructed from durable stainless steel, it is designed for long-term underwater operation in wells with a minimum bore diameter of 11 cm (4.3 inches).

EBERTH 1100W Deep Well Pump with dimensions and specifications

Image 2.1: EBERTH 1100W Deep Well Pump showing its overall dimensions (10cm diameter, 106cm length), 1100W power, 7.7 bar pressure, and 13 kg weight.

Key Features:

  • Powerful Motor: Equipped with an 1100W electric motor for efficient water extraction.
  • Durable Construction: Stainless steel casing ensures corrosion resistance and long service life.
  • Integrated Filter: Prevents dirt particles from entering the pump, ensuring clear water output.
  • High Delivery Height: Capable of pumping water from significant depths, with a maximum delivery height of up to 74 meters.
  • Long Power Cable: Includes a 20-meter electrical cable for flexible installation.
EBERTH Deep Well Pump partially submerged in water

Image 2.2: The EBERTH deep well pump partially submerged, illustrating its intended use for underwater operation.

3. Setup and Installation

Proper installation is crucial for the pump's performance and longevity. Follow these steps carefully.

3.1 Components Check

Before installation, ensure all components are present and undamaged:

  • Deep well pump
  • Control box
  • 20m electrical cable (pre-attached)
  • Safety rope (not included, but highly recommended)
  • Discharge pipe (not included)

3.2 Installation Steps

  1. Prepare the Well: Ensure the well bore has a minimum diameter of 11 cm (4.3 inches) and is free of debris.
  2. Attach Safety Rope: Securely attach a strong, non-corrosive safety rope to the designated eyelets on the pump's top connection. This rope will bear the pump's weight and prevent it from falling.
  3. Top connection of the EBERTH deep well pump

    Image 3.1: Close-up of the pump's top connection, showing the threaded outlet and cable entry point.

  4. Connect Discharge Pipe: Connect a suitable discharge pipe (e.g., PVC or PE pipe) to the pump's threaded outlet. Ensure a watertight seal using thread sealant or tape.
  5. Lower the Pump: Carefully lower the pump into the well using the safety rope. Ensure the pump remains vertical and does not get stuck. The pump should be submerged at least 1 meter below the lowest expected water level and at least 1 meter above the bottom of the well to avoid drawing in sediment.
  6. Person lowering the EBERTH deep well pump into a well

    Image 3.2: A person carefully lowering the deep well pump into a well opening, secured by a rope.

  7. Secure the Cable and Pipe: Secure the electrical cable and discharge pipe to the safety rope at regular intervals (e.g., every 2-3 meters) using cable ties or clamps to prevent strain on the pump connections.
  8. Install Control Box: Mount the control box in a dry, easily accessible location, protected from direct weather exposure.
  9. EBERTH Deep Well Pump Control Box with wiring diagram

    Image 3.3: The EBERTH deep well pump control box, featuring an on/off switch and a wiring diagram for electrical connections.

  10. Electrical Connection: Connect the pump's electrical cable to the control box according to the wiring diagram provided on the control box. Ensure all connections are secure and insulated. Connect the control box to a grounded power supply (230V, 50Hz).
  11. Final Check: Double-check all connections, ensuring the pump is properly submerged and secured.
Diagram of deep well pump installation

Image 3.4: Schematic diagram illustrating the typical installation of a deep well pump, showing the pump submerged, safety rope, pressure pipe, electrical cable, and control box connected to a power source.

4. Operating Instructions

4.1 Initial Startup

  1. Ensure the pump is fully submerged in water.
  2. Turn on the power supply to the control box.
  3. Switch the pump ON using the switch on the control box.
  4. Allow the pump to run for a few minutes to purge any air from the system. Water flow should become steady.

4.2 Normal Operation

The pump is designed for continuous operation within its specified limits. Monitor the water level in the well to prevent dry running. For applications like irrigation, the pump can supply water to sprinklers or hoses.

Sprinkler watering a lawn

Image 4.1: A sprinkler system watering a lawn, demonstrating a common application for the pump's water supply.

Hand watering plants with a hose

Image 4.2: A hand holding a hose nozzle, watering garden plants, illustrating another use for the pumped water.

5. Maintenance

Regular maintenance ensures optimal performance and extends the pump's lifespan.

5.1 General Inspection

  • Periodically check the electrical cable for any signs of damage or wear.
  • Inspect the discharge pipe and connections for leaks.
  • Ensure the control box is clean and dry.

5.2 Cleaning the Filter

The pump features an integrated impurity filter. If you notice a decrease in flow rate, the filter may need cleaning.

  1. Disconnect the pump from the power supply.
  2. Carefully retrieve the pump from the well using the safety rope.
  3. Locate the filter section (perforated area) on the pump body.
  4. Filter section of the EBERTH deep well pump

    Image 5.1: Close-up of the pump's perforated filter section, designed to prevent impurities from entering the pump mechanism.

  5. Clean any accumulated debris from the filter using a brush and clean water.
  6. Re-lower the pump into the well and reconnect the power.

5.3 Winterization (for cold climates)

If the pump is installed in an area subject to freezing temperatures and will not be used during winter:

  • Disconnect power to the pump.
  • Remove the pump from the well.
  • Drain all water from the pump and discharge pipe.
  • Store the pump in a dry, frost-free location.

6. Troubleshooting

Before attempting any repairs, always disconnect the pump from the power supply.

ProblemPossible CauseSolution
Pump does not startNo power supply
Faulty control box
Motor overload protection tripped
Check power connection and circuit breaker
Inspect control box wiring
Reset motor protection (if applicable)
Low or no water flowWater level too low
Clogged filter
Air in the system
Damaged impeller/pump components
Check well water level
Clean pump filter (see Section 5.2)
Allow pump to run to purge air
Contact qualified service personnel
Pump runs but no waterPump not fully submerged
Discharge pipe leak
Check valve issue
Ensure pump is adequately submerged
Inspect discharge pipe for leaks
Check or replace check valve
Excessive noise/vibrationPump not properly secured
Foreign object in pump
Worn bearings
Ensure safety rope is taut and pump is stable
Remove pump and inspect for obstructions
Contact qualified service personnel

7. Technical Specifications

SpecificationValue
ModelWP1-4TP1100
Power1100 Watts
Voltage230 Volts
Max Flow Rate140 Litres per minute
Max Delivery Height74 meters
Dimensions (L x W x H)10 x 10 x 106 cm
Weight13 Kilograms
MaterialStainless Steel
Cable Length20 meters
Min. Well Diameter11 cm (4 inches)
Performance data table for EBERTH deep well pumps

Image 7.1: Performance data table showing flow rates (m³/h and L/min) at various total delivery heights for different EBERTH deep well pump models, including the 1100W model.

8. Warranty and Support

EBERTH products are designed for quality and reliability. In the event of a defect, EBERTH offers repair services.

8.1 Repair Service

Defective devices are repaired quickly and reliably at our service center in Germany. Repaired units are returned to the customer free of charge.

8.2 Contact Information

For support, warranty claims, or spare parts inquiries, please contact your retailer or visit the official EBERTH website for customer service details.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.