1. Introduction
This manual provides comprehensive instructions for the proper setup, operation, maintenance, and troubleshooting of your U.S. Solid Digital Precision Lab Scale, Model USS-DBS00059. This electronic balance is designed for accurate weighing in various applications, offering a maximum capacity of 15KG with a readability of 0.1g. It features a durable stainless steel weighing pan, multiple measurement units, AC/DC power options, and essential functions such as counting and tare.
Please read this manual thoroughly before using the scale to ensure correct operation and to maximize its lifespan.
2. Safety Precautions
- Operate the scale on a stable, level, and vibration-free surface.
- Avoid placing the scale near strong electromagnetic fields, heat sources, or direct sunlight.
- Do not expose the scale to extreme temperatures or humidity.
- Use only the provided AC adapter or specified DC batteries.
- Keep the weighing pan and surrounding area clean and free from debris.
- Do not overload the scale beyond its maximum capacity of 15KG.
- Disconnect power before cleaning or if the scale will not be used for an extended period.
3. Product Overview
The U.S. Solid Digital Precision Lab Scale (USS-DBS00059) is equipped with features designed for reliable and precise measurements.
Key Features:
- Capacity: 15KG with 0.1g readability.
- Weighing Pan: 150x180 mm stainless steel for corrosion resistance.
- Display: Backlit LCD for clear readings.
- Power: AC (100-240V) and DC (9V battery) operation.
- Units: 11 selectable measurement units (g, ct, oz, ozt, lb, GN, t, dwt, kg, dr, tlT, N, %).
- Functions: Weighing, parts counting, tare, unit conversion, manual calibration, and fault alerts.
- Construction: Durable ABS housing with height-adjustable feet and a level bubble.
Components:


4. Setup
4.1 Unpacking
Carefully remove all components from the packaging. Verify that all items listed in Figure 3.2 are present and undamaged. Retain the packaging for future transport or storage.
4.2 Placement
Place the scale on a firm, level, and stable surface. Ensure the location is free from vibrations, drafts, direct sunlight, and rapid temperature changes, which can affect measurement accuracy.
4.3 Leveling the Scale
The scale must be perfectly level for accurate readings. Adjust the four height-adjustable feet located on the bottom of the scale until the bubble in the built-in level indicator is centered within the red circle.


4.4 Power Connection
- AC Power: Connect the provided AC adapter to the power input port on the rear of the scale, then plug it into a suitable electrical outlet (100-240V).
- DC Power (Battery): For portable use, open the battery compartment on the bottom of the scale (Figure 4.3) and insert a 9V DC battery, ensuring correct polarity.

4.5 Initial Warm-up
After connecting power, allow the scale to warm up for at least 30 minutes before performing critical measurements. This stabilizes the internal components and ensures optimal accuracy.

5. Operating Instructions
5.1 Control Panel Overview


5.2 Power On/Off
- Press the ON/OFF button to turn the scale on.
- Press and hold the ON/OFF button to turn the scale off.
5.3 Basic Weighing
- Ensure the scale is level and powered on.
- Wait for the display to show "0.0" or "0.00" (depending on the unit).
- Carefully place the item to be weighed onto the center of the stainless steel weighing pan.
- Read the stable weight displayed on the LCD.
5.4 Tare Function
The tare function allows you to subtract the weight of a container, so only the net weight of the contents is measured.
- Place an empty container on the weighing pan.
- Press the TARE/ZERO button. The display will reset to "0.0" or "0.00".
- Add the material to be weighed into the container. The display will show the net weight of the material.
5.5 Unit Conversion
The scale supports 11 different measurement units.
- Press the UNIT button repeatedly to cycle through the available units: g, ct, oz, ozt, lb, GN, t, dwt, kg, dr, tlT, N, and %.
- The selected unit will be indicated on the LCD.

5.6 Parts Counting (PCS)
This function allows you to count a large number of identical items by weight.
- Place a known quantity of items (e.g., 10, 20, 50, 100) on the pan.
- Press the PCS button. The display will show a prompt for sample size (e.g., "P-10").
- Press the UNIT button to select the sample size that matches the number of items you placed on the pan.
- Press the PCS button again to confirm. The scale is now in counting mode.
- Add more items of the same type to the pan, and the display will show the total count.

5.7 Calibration
Regular calibration ensures the accuracy of your scale. It is recommended to calibrate the scale after initial setup, if it has been moved, or if you suspect inaccurate readings. A calibration weight (not included) is required.
- Ensure the scale is powered on and the pan is empty.
- Press and hold the CAL button until "CAL" appears on the display.
- The display will then show the required calibration weight (e.g., "15000g").
- Carefully place the specified calibration weight onto the center of the weighing pan.
- Wait for the display to show "PASS" or return to normal weighing mode, indicating successful calibration.
- Remove the calibration weight.
6. Maintenance
6.1 Cleaning
- Always disconnect the power supply before cleaning.
- Wipe the scale's housing with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- The stainless steel weighing pan can be removed and cleaned with mild soap and water, then dried thoroughly before reattaching.
- Ensure no liquids enter the internal components of the scale.
6.2 Storage
When not in use for extended periods, store the scale in a dry, dust-free environment at room temperature. If using battery power, remove the battery to prevent leakage.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Scale does not power on | No power supply; AC adapter unplugged; Dead battery. | Check AC adapter connection; Replace 9V battery. |
| Inaccurate readings | Scale not level; Drafts or vibrations; Needs calibration; Overloaded. | Adjust leveling feet; Move to a stable environment; Perform calibration; Do not exceed 15KG. |
| Display shows "OUE" or "EEEE" | Overload error. | Remove excess weight from the pan. |
| Display shows "UNST" | Unstable reading. | Ensure scale is on a stable surface, free from vibrations or air currents. |
| Display shows "LO" | Low battery. | Replace the 9V battery or use AC power. |
8. Specifications

| Specification | Value |
|---|---|
| Model Number | USS-DBS00059 |
| Brand | U.S. Solid |
| Capacity | 15 Kilograms (15KG) |
| Readability / Accuracy | 0.1 Grams |
| Weighing Pan Material | Stainless Steel |
| Weighing Pan Dimensions | 150 x 180 mm |
| Display Type | Backlit LCD |
| Power Supply | AC 100-240V; DC 9V Battery |
| Measurement Units | g, ct, oz, ozt, lb, GN, t, dwt, kg, dr, tlT, N, % |
| Functions | Weighing, Counting, Tare, Unit Conversion, Calibration |
| Item Weight | 4.33 pounds |
| Package Dimensions | 11.61 x 9.37 x 5.55 inches |
9. Warranty and Support
U.S. Solid products are manufactured to high-quality standards. For information regarding warranty coverage, please refer to the warranty card included with your product or visit the official U.S. Solid website.
If you encounter any issues or require technical assistance, please contact U.S. Solid customer support. Contact details can typically be found on the product packaging, the official website, or through your purchase platform.