1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your EMKE SFTR1640X1W-DRVC hot water bathroom radiator. Please read these instructions carefully before installation and use to ensure safe and efficient operation of the product. Keep this manual for future reference.
2. Safety Instructions
- Ensure the radiator is installed by a qualified professional in accordance with local building and plumbing regulations.
- Do not cover the radiator with flammable materials.
- Keep children and pets away from the hot surface of the radiator to prevent burns.
- Regularly check for any signs of leaks or damage. If detected, turn off the heating system and contact a professional.
- The radiator is designed for hot water central heating systems only. Do not connect to other types of heating systems.
- Do not use abrasive cleaners or solvents on the radiator surface, as this may damage the finish.
3. Package Contents
Please check that all components are present and undamaged before proceeding with installation.
- EMKE Bathroom Radiator (1 unit)
- Towel Rail (if applicable to model)
- Mounting Set (4 blind plugs, 4 wall plugs, 4 long screws, 4 small screws, 4 rubber rings)
- Installation Instructions

4. Setup and Installation
The EMKE bathroom radiator is designed for flexible installation. It can be mounted with the connections on either the left or right side.
4.1 Wall Mounting
- Prepare the Wall: Choose a suitable location on a solid wall. Ensure there are no hidden pipes or electrical wires.
- Mark Drilling Points: Use the provided mounting brackets and a spirit level to mark the drilling points on the wall.
- Drill Holes: Drill holes of appropriate size and depth for the wall plugs. Insert the wall plugs.
- Attach Brackets: Secure the mounting brackets to the wall using the long screws.
- Mount Radiator: Carefully lift the radiator and attach it to the wall brackets. Ensure it is securely seated.
- Adjust Wall Distance: The wall distance is adjustable between 99-115 mm, allowing for optimal positioning.

4.2 Plumbing Connection
- The radiator features a universal G1/2" connection thread with a 50 mm connection distance.
- The radiator can be installed with the connections on the left or right side by simply inverting the unit.
- Important: A valve is not included with this product. Please acquire a suitable valve according to your specific system requirements.
- Connect the radiator to your hot water central heating system. Ensure all connections are sealed properly to prevent leaks.

5. Operating Instructions
Once installed and connected to your hot water central heating system, the EMKE radiator will provide efficient heat distribution.
- Initial Start-up: After installation, slowly fill the heating system with water and bleed any air from the radiator using the bleed valve (if present on your valve).
- Heat Distribution: The flat steel design ensures uniform and efficient heat distribution, quickly warming your bathroom and drying towels.
- Temperature Control: Use your heating system's thermostat or the radiator valve (not included) to control the heat output. The recommended inlet/outlet water temperature is 75°C/65°C.

6. Maintenance
- Cleaning: Clean the radiator regularly with a soft, damp cloth. For stubborn dirt, use a mild, non-abrasive cleaning agent. Avoid harsh chemicals or abrasive materials that could damage the finish.
- Bleeding: Periodically bleed air from the radiator to maintain optimal heating efficiency. Air trapped in the system can reduce heat output.
- Inspection: Annually inspect all connections for any signs of leaks or corrosion. The high-quality steel and eco-friendly coating are designed to protect against rust and water leaks, making it suitable for humid environments.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Radiator not heating up. | Air trapped in the system; heating system off; faulty valve. | Bleed the radiator; check heating system power; inspect/replace valve. |
| Uneven heating. | Air trapped in the system. | Bleed the radiator thoroughly. |
| Water leaks from connections. | Loose connections; damaged seals. | Tighten connections; replace seals. If problem persists, contact a professional. |
| Noise from radiator. | Air in the system; water flow issues. | Bleed the radiator; check system pressure. |
8. Specifications
| Feature | Detail |
|---|---|
| Model Number | SFTR1640X1W-DRVC |
| Dimensions (Height x Width) | 1599 x 400 mm |
| Color | White |
| Material | High-quality Steel (SPCC) with eco-friendly coating |
| Power Output | 684 W |
| Heating Type | Hot Water Central Heating |
| Recommended Application Area | Up to 7 m² |
| Connector Thread | G1/2" |
| Connection Distance | 50 mm |
| Adjustable Wall Distance | 99 - 115 mm |
| Recommended Water Temperature (Inlet/Outlet) | 75°C / 65°C |
| Weight | 16.2 kg |

9. Warranty and Support
EMKE is committed to providing high-quality products and excellent customer service.
- Warranty: This product comes with a 2-year repair service.
- Return Policy: A 14-day return policy is offered for your peace of mind.
- Customer Support: For any questions, technical assistance, or warranty claims, please contact EMKE customer service through your purchase platform or the official EMKE website.