1. Introduction
This manual provides essential instructions for the safe and effective use of your Dario Blood Pressure Monitor Gen2. Please read this manual thoroughly before using the device and retain it for future reference. The Dario Blood Pressure Monitor Gen2 is designed for accurate measurement of systolic and diastolic blood pressure, as well as pulse rate, in adults. It features an automatic inflation system, a clear LCD display, and Bluetooth connectivity for smart health management.

Image: The Dario Blood Pressure Monitor Gen2, showing the main unit, arm cuff, and included AAA batteries.
2. Safety Information
Please observe the following safety precautions to ensure proper operation and to prevent injury or damage to the device:
- The device is not intended for use in environments with high moisture or humidity beyond specified levels.
- It is unsuitable for Magnetic Resonance (MR) environments.
- This device is intended for adult use only.
- Do not use this device on infants or individuals who cannot express consent.
- Consult your physician before using this device if you have any medical conditions.
- Do not self-diagnose or self-treat based on measurements from this device. Always consult a healthcare professional.
- Keep the device out of reach of children and pets.
3. What's in the Box
Upon unpacking, please verify that all the following components are included:

Image: A visual representation of the Dario Blood Pressure Monitor Gen2 package contents, showing the monitor, cuff, and travel bag.
- Dario Blood Pressure Monitor Gen2
- Pressure Cuff (Large, 8.75-16.5 inches / 22-42 cm)
- 4 Alkaline AAA Batteries (Note: No A/C adapter is included or needed)
- Travel Bag
- Warranty Card
- Quick Guide
- Owner's Manual (this document)
4. Setup
4.1. Battery Installation
The Dario Blood Pressure Monitor Gen2 operates on 4 AAA batteries, which are included. To install the batteries:
- Locate the battery compartment on the back of the monitor.
- Open the battery compartment cover.
- Insert the 4 AAA batteries, ensuring the correct polarity (+ and -) as indicated inside the compartment.
- Close the battery compartment cover securely.
The device is now ready for use. The monitor does not require an A/C adapter.
5. Operating Instructions
5.1. Preparing for Measurement
For accurate readings, follow these guidelines before taking a measurement:
- Avoid showering, exercising, smoking, and consuming caffeine for at least 30 minutes before testing.
- Rest quietly for 5 minutes before taking a measurement.
- Do not talk during the measurement process.
- Sit upright in a chair with your back supported and your feet flat on the floor.
- Ensure your arm is supported so that your elbow is approximately at heart level.

Image: Visual instructions for preparing to take a blood pressure measurement, including sitting posture, arm position, and activities to avoid.
5.2. Applying the Arm Cuff
The adjustable arm cuff (8.75-16.5 inches) is designed for comfortable and accurate fit. Follow these steps:
- Step 1: Put on the cuff with your palm facing up. The cuff should be 0.8 - 1.2 inches (2-3 cm) above the elbow joint.
- Step 2: Wrap the end of the cuff over your arm to secure it in place. Do not make it too tight.
- Step 3: Place your arm on a table with your palm facing up.
- Step 4: Make sure the cuff is at the same height as your heart.
- Step 5: Sit up straight and rest your feet flat on the ground.

Image: Step 1 of cuff application, showing the cuff positioned correctly above the elbow.

Image: Step 2 of cuff application, demonstrating how to wrap and secure the cuff.

Image: Step 3 of cuff application, showing the arm resting on a table.

Image: Step 4 of cuff application, illustrating the correct height of the cuff relative to the heart.

Image: Step 5 of cuff application, showing the user sitting upright with feet flat on the ground.
5.3. Taking a Measurement
Once the cuff is correctly applied and you are in the proper position:
- Press the START / STOP button on the monitor.
- The cuff will automatically inflate. Remain still and silent during inflation and measurement.
- Once the measurement is complete, the cuff will deflate, and your systolic blood pressure (SYS), diastolic blood pressure (DIA), and pulse rate (PUL) will be displayed on the LCD screen.
- The monitor will automatically save the reading.

Image: The clear LCD display of the Dario Blood Pressure Monitor Gen2, highlighting the systolic, diastolic, and heart rate readings, along with the color-coded blood pressure level indicator.
The display features a color-coded indicator on the right side, which visually represents your blood pressure level according to standard guidelines:
- Red: Hypertensive Crisis
- Orange: High BP 2
- Yellow: High BP 1
- Light Green: Prehypertension
- Green: Normal
5.4. Irregular Heartbeat (IHB) Detection
The Dario Blood Pressure Monitor Gen2 is equipped with an Irregular Heartbeat (IHB) detection feature. If an irregular heartbeat is detected during the measurement, a corresponding symbol will appear on the display. This device does not replace a cardiac examination but serves to detect pulse irregularities at an early stage. If this symbol appears frequently, consult your physician.
6. Smart Features and App Connectivity
6.1. Bluetooth Connectivity and Dario App
The monitor features Bluetooth connectivity, allowing you to synchronize your readings with the Dario App on your smartphone or tablet. This enables comprehensive tracking and management of your blood pressure data.
- Download the Dario App from your device's app store.
- Follow the in-app instructions to pair your Dario Blood Pressure Monitor Gen2 via Bluetooth.
- Ensure your phone is nearby when taking a measurement for automatic data transmission. If not, the readings will transfer the next time the device connects to the app.

Image: Screenshots illustrating the Dario App's features, including the ability to share logbooks with a doctor, view unlimited readings, and track trends over time.
6.2. Data Management and Sharing
- Unlimited Readings: The Dario App allows for unlimited storage of your blood pressure readings, providing a comprehensive history.
- Trend Tracking: Visualize your blood pressure trends over various periods (e.g., 7, 30, 90 days) within the app.
- Share with Doctor: Easily share your blood pressure logbook with your healthcare provider or loved ones directly from the app via email, in various formats like PDF or CSV.

Image: A doctor reviewing blood pressure data shared from the Dario App, demonstrating the ease of sharing health information.
6.3. Dual User Mode
The device supports a Dual User Mode, allowing two individuals to store their measurements separately on the device itself. The app, however, is typically linked to a single user account for personalized tracking.
- To switch between users on the device, press the 'M' button (Memory button) and then the arrow keys to select User 1 or User 2.
- Each user's readings will be stored independently, up to 400 records per user.

Image: An illustration depicting the dual user functionality of the Dario Blood Pressure Monitor, allowing two users to store their data.
7. Memory Function
The Dario Blood Pressure Monitor Gen2 can store up to 400 memory records directly on the device, complete with dates and times. This allows you to review your past measurements even without the app.
- To access stored readings, press the M button.
- Use the arrow buttons to navigate through previous measurements.
8. Maintenance
8.1. Cleaning
- Clean the monitor and cuff with a soft, dry cloth.
- If necessary, use a cloth lightly dampened with water or a mild detergent. Do not use abrasive cleaners or immerse the device in water.
8.2. Storage
- Store the device in its provided travel bag when not in use.
- Keep the monitor in a cool, dry place, away from direct sunlight, extreme temperatures, and humidity.
8.3. Battery Replacement
- Replace all four AAA batteries when the low battery indicator appears on the display.
- Always replace all batteries at the same time with new ones of the same type.
- Dispose of used batteries according to local regulations.
9. Troubleshooting
If you encounter issues with your Dario Blood Pressure Monitor Gen2, refer to the table below for common problems and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Batteries are dead or incorrectly inserted. | Check battery polarity; replace with new AAA batteries. |
| Inaccurate readings. | Incorrect cuff placement, movement during measurement, or improper posture. | Review "Preparing for Measurement" and "Applying the Arm Cuff" sections. Ensure stillness and correct posture. |
| Cuff does not inflate or inflates improperly. | Cuff hose not securely connected, or air leakage. | Ensure the cuff hose is firmly plugged into the monitor. Check cuff for damage. |
| Bluetooth connection issues. | Bluetooth is off on phone, app not open, or pairing issue. | Ensure Bluetooth is enabled on your smartphone. Open the Dario App. Re-pair the device if necessary through the app settings. |
| Readings not transferring to app. | Phone not nearby during measurement, or app not active. | Keep phone with active Dario App near the monitor during measurement. If readings are missed, they should transfer upon next successful connection. |
10. Specifications
| Feature | Detail |
|---|---|
| Model Name | Gen2 |
| Item Model Number | DH-1217-05 |
| Product Dimensions | 7.63"L x 5.13"W x 3.13"Th (Monitor) |
| Item Weight | 282 Grams (approx. 9.95 ounces) |
| Power Source | 4 AAA Batteries (included) |
| Display Type | Large Backlit LCD Display |
| Cuff Size | 8.75-16.5 inches (22-42 cm) |
| Memory Capacity | 400 records with date/time (on device, per user) |
| Connectivity | Bluetooth |
| Age Range | Adult |
| Manufacturer | GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD |
| FDA Cleared | Yes |
| FSA/HSA Eligible | Yes |
11. Warranty and Support
For warranty information, please refer to the Warranty Card included in your product packaging. For technical support or further assistance, please contact Dario customer service. Contact details can typically be found on the manufacturer's website or the product packaging.