Fireangel FA6620-R-T2

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

FireAngel Optical Smoke Alarm FA6620-R-T2 User Manual

Model: FA6620-R-T2

Introduction

The FireAngel FA6620-R-T2 Optical Smoke Alarm is designed to provide early warning of fire by detecting smoke. This device is equipped with an optical sensing chamber, optimized for detecting slow-burning fires that produce thick white smoke. It features a 10-year sealed-for-life battery, ensuring continuous operation without battery replacement for the product's lifespan. This model serves as a direct replacement for FireAngel ST-622 and ST-620 smoke alarms.

Two FireAngel FA6620-R-T2 optical smoke alarms, white and circular, with a central test button and the FireAngel logo.

Image: Two FireAngel FA6620-R-T2 optical smoke alarms.

What's in the Box

Each twin pack of FireAngel FA6620-R-T2 Optical Smoke Alarms includes:

  • 2 x Optical Smoke Alarms complete with Sealed Batteries
  • 2 x Baseplates
  • 1 x Instruction Manual

Setup and Installation

The FireAngel FA6620-R-T2 is designed for easy installation. It can be mounted using the supplied baseplates and screws. If you are replacing an older FireAngel ST-622, ST-620, or ST-750 model, these new alarms are designed to fit onto the existing baseplates, simplifying the upgrade process.

Mounting Instructions:

  1. Secure the provided baseplate to the ceiling using appropriate screws.
  2. Align the smoke alarm with the secured baseplate.
  3. Push and twist the alarm clockwise onto the baseplate until it is securely fastened.
A hand demonstrating how to twist the FireAngel smoke alarm onto its baseplate, which is already secured to a ceiling.

Image: Demonstration of easy installation by twisting the alarm onto its baseplate.

Operating Instructions

Testing the Alarm:

Regular testing ensures your smoke alarm is functioning correctly. Press the large test button on the alarm for approximately 5 seconds. A loud, high-pitched sound will indicate that the alarm is working. For a quiet self-test, press the button once. For a loud test, press it twice.

Silence Function (False Alarms):

In the event of a known false alarm (e.g., from cooking fumes), press the test button for 5 seconds to temporarily silence the alarm for 8 minutes. The alarm will reset to normal mode after this period.

Sleep Easy Function (Low Battery):

If a low battery alert occurs, particularly at night, you can silence the smoke detector for 8 hours by pressing the test button. During this 'Sleep Easy' mode, the alarm will be muted, but the red LED will continue to flash, and the alarm will still detect smoke. The device should be replaced within 30 days of the first low battery alert.

A FireAngel smoke alarm on a white surface, highlighting its compact design and features like optical smoke sensor and Sleep Easy function.

Image: Compact design of the smoke alarm, illustrating its optical sensor and Sleep Easy feature.

Maintenance

Proper maintenance ensures the longevity and effectiveness of your smoke alarm.

  • Test Monthly: Perform a self-test at least once a month to confirm functionality.
  • Vacuum Every 3 Months: Gently vacuum the alarm's vents every three months to remove dust and debris that could obstruct the sensor.
  • Do NOT Use Cleaners or Solvents: Avoid using any cleaning agents, sprays, or solvents on the device as they can damage the sensor or internal components.
  • Do NOT Paint the Alarm: Painting the alarm can block the vents and interfere with its ability to detect smoke.
  • Cover During DIY Tasks: If performing dusty DIY tasks nearby, temporarily cover the alarm to prevent dust ingress, and uncover it immediately afterward.
  • Battery Life: The alarm is fitted with a sealed, tamper-proof battery designed to last the entire 10-year lifespan of the unit. The battery is not replaceable.
  • Replacement: Smoke alarms should be replaced every 10 years from the date of manufacture.
A list of 'For Best Results' tips for smoke alarm maintenance, including testing, vacuuming, and avoiding cleaners or paint.

Image: Maintenance tips for optimal smoke alarm performance.

Placement Guidelines

Correct placement is crucial for effective smoke detection.

  • Smoke detectors should be sited at least 300 mm (approximately 12 inches) from light fittings and walls to ensure proper air circulation and smoke detection.
  • This alarm is not suitable for placement in kitchens or bathrooms due to potential nuisance alarms from cooking fumes or steam.
  • The device is suitable for use in leisure accommodation vehicles (LAV).
An image showing placement guidelines for smoke detectors, including distance from walls and suitability for different room types.

Image: Visual guide for optimal smoke alarm placement.

Troubleshooting

  • Intermittent Chirping: If the alarm emits an unusual or intermittent chirping sound, this typically indicates a low battery warning. Utilize the 'Sleep Easy' function to silence it for 8 hours, and plan to replace the unit within 30 days. Also, check the device's location and vacuum the alarm to ensure no dust is interfering with its operation.
  • Alarm Not Sounding During Test: Ensure you are pressing the test button for the full 5 seconds. If the alarm still does not sound, the unit may be faulty and should be replaced immediately.
  • Frequent Nuisance Alarms: If the alarm frequently triggers without a fire, review its placement. It should not be located near kitchens, bathrooms, or areas with high humidity or cooking fumes.

Specifications

BrandFireAngel
Model NumberFA6620-R-T2
Power SourceBattery Powered (10-year sealed battery)
Sensor TypeOptical
Product Dimensions11.8D x 11.8W x 3.2H Centimeters
Item Weight138 Grams
MaterialPlastic
ColorWhite
Alarm Sound Level85 dB(A) at 3 meters (as per product image)

Warranty and Support

The FireAngel FA6620-R-T2 Optical Smoke Alarm comes with a 5-year manufacturer's warranty, providing assurance of its quality and reliability. For any support inquiries, troubleshooting assistance beyond this manual, or warranty claims, please refer to the official FireAngel website or contact their customer service directly.

© 2025 FireAngel. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.