1. Product Overview

The SINOTIMER CN101S is a versatile digital LCD timer switch designed for precise control of electrical appliances. It features a programmable 7-day weekly schedule with 1-second interval accuracy, making it suitable for a wide range of applications in homes and offices. Its compact design allows for panel or wall mounting.

Key Features:

  • Digital LCD display for clear readability.
  • Minimum 1-second interval timing.
  • Up to 8 ON/OFF programs per day, with 15 combinations for weekly scheduling.
  • 24-hour / 7-day programmable operation.
  • Countdown function with a maximum of 24 hours to OFF.
  • Built-in rechargeable battery to retain memory during power failures (up to 60 days).
  • Manual ON/OFF/AUTO control.

2. Safety Information

Please read and understand all instructions before installing or operating this device. Improper installation or use can lead to electrical shock, fire, or damage to the device and connected equipment. Always disconnect power at the circuit breaker before performing any wiring.

  • Installation should be performed by a qualified electrician or knowledgeable individual.
  • Ensure the power supply voltage matches the device's specifications (220V AC 50/60Hz for this model).
  • Do not exceed the maximum load rating of 16A.
  • Keep the device away from water and excessive humidity.
  • Do not attempt to disassemble or repair the device yourself.

3. Product Components and Display

SINOTIMER CN101S Digital Timer Switch Front View with Labeled Buttons and LCD Screen

Figure 3.1: Front View with Controls and Display. This image shows the front of the CN101S timer switch, highlighting the LCD screen and various control buttons. The screen displays the current time (AM/PM, Hour, Minute, Second), day of the week, and status indicators (ON/AUTO/OFF). Buttons include 'P' (Program), 'D+' (Day), 'H+' (Hour), 'M+' (Minute), 'S+' (Second), 'R' (Reset), and a 'Clock' button. A 'MANUAL' button is also visible for manual control, and a red working indicator LED.

SINOTIMER CN101S Digital Timer Switch Dimensions and Basic Wiring Diagram

Figure 3.2: Dimensions and Basic Wiring Diagram. This image provides the physical dimensions of the timer switch (60mm x 60mm x 32mm) and a simplified internal wiring diagram. It illustrates the power input (L, N) and power output (N, L) connections, showing how the timer controls the load.

SINOTIMER CN101S Digital Timer Switch Back View with Terminal Labels

Figure 3.3: Back View with Terminal Labels. This image displays the back of the timer switch, showing the five terminal connections labeled 1 through 5. These are for LINE, NEUT (Input), NEUT (Output), and LOAD, along with input and output voltage/current specifications.

4. Setup and Initial Configuration

4.1. Initial Power-up and Battery Charging

The CN101S timer switch includes a built-in rechargeable battery. Upon first use or after a long period of storage, connect the timer to power for at least 30 minutes to charge the internal battery. This battery maintains the programmed settings and current time during power outages for up to 60 days.

4.2. Resetting the Timer

To clear all settings and reset the timer to its default state, insert a small, non-metallic pointed object (like a toothpick) into the 'R' (Reset) hole on the front panel and press gently. The LCD display will show '0:00' and all programs will be erased.

4.3. Setting Current Time and Day

  1. Press the Clock button and hold it.
  2. While holding the Clock button, press D+ to set the current day of the week (MO, TU, WE, TH, FR, SA, SU).
  3. While holding the Clock button, press H+ to set the current hour (0-23 for 24-hour format, or 1-12 for 12-hour format).
  4. While holding the Clock button, press M+ to set the current minute (0-59).
  5. Release the Clock button. The time is now set.
  6. To switch between 12-hour (AM/PM) and 24-hour formats, press the Clock button and P button simultaneously.

4.4. Wiring Instructions

Refer to Figure 3.3 for terminal identification and Figure 3.2 for a simplified wiring diagram. Ensure power is disconnected before wiring.

  • Terminals 1 & 2 (Input): Connect your main power supply (LINE and NEUTRAL) to these terminals. For 220V AC, connect the live wire to terminal 1 (LINE) and the neutral wire to terminal 2 (NEUT).
  • Terminals 3 & 4 (Output): These are the switched output terminals. Connect the neutral wire of your appliance to terminal 3 (NEUT) and the live wire of your appliance to terminal 4 (LOAD).
  • Terminal 5: This terminal is typically for the common neutral connection for the load, often bridged with terminal 3. Consult a qualified electrician if unsure about specific wiring configurations for your application.

5. Operating Instructions

5.1. Programming ON/OFF Times

The timer allows for up to 8 ON/OFF programs per day, with 15 different day combinations for weekly scheduling.

  1. Press the P button once. The display will show '1 ON'. This is for the first ON program.
  2. Press D+ to select the day(s) for this program. You can cycle through various combinations: every day, specific days (e.g., MO-FR, SA-SU), or individual days.
  3. Press H+ to set the hour for '1 ON'.
  4. Press M+ to set the minute for '1 ON'.
  5. Press the P button again. The display will show '1 OFF'. This is for the first OFF program.
  6. Repeat steps 2-4 to set the day(s), hour, and minute for '1 OFF'.
  7. Continue pressing P to cycle through '2 ON', '2 OFF', up to '8 ON', '8 OFF', setting each program as needed.
  8. After setting all desired programs, press the Clock button to exit programming mode and return to the current time display.

5.2. Manual Control (ON/AUTO/OFF)

Press the MANUAL button to cycle through the three operating modes:

  • ON: The connected appliance is continuously ON, overriding all programmed settings.
  • AUTO: The timer operates according to the programmed ON/OFF schedules.
  • OFF: The connected appliance is continuously OFF, overriding all programmed settings.

For automatic operation, ensure the timer is set to AUTO mode.

5.3. Countdown Function

The countdown function allows the timer to turn OFF after a specified duration, up to 24 hours.

  1. Press the S+ button. The display will show 'd ON' or 'd OFF' and the countdown time.
  2. Press H+ to set the countdown hour.
  3. Press M+ to set the countdown minute.
  4. Press S+ again to start the countdown. The timer will turn OFF after the set duration.
  5. To cancel the countdown, press S+ again.

6. Maintenance

The SINOTIMER CN101S is designed for low maintenance. Follow these guidelines to ensure its longevity:

  • Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the device in water.
  • Battery: The built-in rechargeable battery is designed to last for the lifespan of the product. Regular connection to power will keep it charged. If the timer is stored for extended periods, connect it to power periodically to maintain battery health.
  • Storage: Store the timer in a cool, dry place away from direct sunlight and extreme temperatures.

7. Troubleshooting

ProblemPossible CauseSolution
Display is blank or unresponsive.
  • No power supply.
  • Internal battery fully discharged.
  • Device malfunction.
  • Check power connections and circuit breaker.
  • Connect the timer to power for at least 30 minutes to charge the battery.
  • Perform a full reset by pressing the 'R' button. If the issue persists, contact support.
Timer not switching ON/OFF at programmed times.
  • Timer is not in AUTO mode.
  • Incorrect program settings.
  • Current time/day is incorrect.
  • Wiring issue.
  • Press the 'MANUAL' button until 'AUTO' is displayed.
  • Review and re-enter your ON/OFF programs carefully.
  • Verify and correct the current time and day settings.
  • Ensure all wiring connections are secure and correct (refer to Section 4.4).
Countdown function not working.
  • Countdown not initiated correctly.
  • Countdown cancelled.
  • Ensure you press 'S+' after setting the countdown time to start it.
  • Do not press 'S+' again after starting the countdown unless you intend to cancel it.

8. Specifications

ParameterValue
Model NumberCN101S
Power Supply220V AC 50/60Hz
Max Load16A
Minimum Interval1 second
Timing Range1 second to 168 hours (7 days)
Setting Groups8 ON/OFF per day (15 combinations)
Memory Retention (Black-out)60 days (with built-in rechargeable battery)
InstallationPanel/Wall mounted
Dimensions (L x W x H)5.51 x 2.95 x 1.97 inches (approx. 140 x 75 x 50 mm)
Item Weight2.39 ounces (approx. 67.7 grams)
UPC780744817941

9. Warranty and Support

For warranty information and technical support, please contact the manufacturer, SINOTIMER, directly through their official website or the retailer from whom you purchased the product. Keep your purchase receipt as proof of purchase.

© 2025 SINOTIMER. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.