1. Introduction
This user manual provides comprehensive instructions for the safe and efficient operation, installation, and maintenance of your SHARP UL-C09EA-W Portable Air Conditioner. Please read this manual thoroughly before using the appliance and retain it for future reference.
The SHARP UL-C09EA-W is a versatile portable air conditioning unit designed to cool rooms up to 26 square meters, featuring a cooling capacity of 2.6 kW (9,000 BTU). It also includes a dehumidifier function and multiple fan speeds to ensure an ideal indoor climate.
2. Safety Information
Always observe the following safety precautions to reduce the risk of fire, electric shock, or injury.
- Ensure the power supply matches the voltage specified on the appliance's rating label (240V AC).
- Do not operate the unit with a damaged power cord or plug.
- Keep the appliance away from heat sources and direct sunlight.
- Do not block the air inlets or outlets.
- Ensure proper ventilation when operating the unit.
- Do not insert objects into the air vents.
- Unplug the unit before cleaning or performing any maintenance.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
3. Product Overview
3.1 Components



3.2 Control Panel and Remote Control
The unit features an intuitive LED display on the top panel and comes with a remote control for convenient operation.

The remote control (included with 2x AAA batteries) provides full functionality from a distance, allowing you to adjust settings without directly interacting with the unit.
4. Setup
Proper setup is crucial for the efficient operation of your portable air conditioner.
- Unpacking: Carefully remove the unit and all accessories from the packaging. Retain packaging for future storage or transport.
- Positioning: Place the air conditioner on a flat, stable surface. Ensure there is adequate space around the unit for proper airflow (at least 20 cm from walls or furniture). The unit is equipped with castors for easy mobility.
- Exhaust Hose Installation:
- Attach the exhaust hose to the designated outlet on the rear of the unit.
- Connect the funnel adapter to the other end of the exhaust hose.
- Extend the exhaust hose to a window or other suitable opening to vent hot air outside. Ensure the hose is as straight and short as possible to maximize efficiency.
- Window Kit (Optional/Recommended): For optimal performance, use a window sealing kit (not explicitly listed as included, but implied by "Fenster" installation method) to prevent hot air from re-entering the room.
- Power Connection: Plug the power cord into a grounded electrical outlet (240V AC).

5. Operating Instructions
Your SHARP UL-C09EA-W offers various functions for customized comfort.
5.1 Power On/Off
Press the Power button on the control panel or remote control to turn the unit on or off.
5.2 Mode Selection
Press the Mode button to cycle through available operating modes:
- Cooling Mode: For active cooling of the room. Set your desired temperature between 16°C and 35°C.
- Dehumidifier Function: Removes excess moisture from the air, improving comfort in humid conditions.
- Fan Mode: Circulates air without cooling.
5.3 Fan Speed Adjustment
In Cooling or Fan mode, press the Fan Speed button to select from three fan speeds: High, Medium, or Low. The noise level varies with fan speed (60-64 dB(A)).
5.4 Temperature Setting
Use the Temperature Up (+) and Temperature Down (-) buttons to adjust the desired room temperature in Cooling Mode.
5.5 Timer Function
The timer function allows you to set a specific time for the unit to turn on or off automatically.
5.6 Sleep Mode
Activate Sleep Mode for quieter operation and gradual temperature adjustments during nighttime hours, promoting a comfortable sleeping environment.
5.7 Auto Restart Memory
In case of a power outage, the unit will automatically restart with the last used settings once power is restored.
5.8 Child Lock
The child lock feature prevents accidental changes to settings, ensuring continuous operation as desired.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner.
- Cleaning the Air Filter: The air filter should be cleaned regularly (e.g., every two weeks or as needed) to maintain air quality and cooling efficiency.
- Unplug the unit before cleaning.
- Remove the air filter (refer to the full manual for location).
- Wash the filter with lukewarm water and a mild detergent. Rinse thoroughly and allow it to air dry completely before reinserting.
- Cleaning the Unit Exterior: Wipe the exterior of the unit with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
- Draining Water: The unit may accumulate condensed water, especially in dehumidifier mode. Refer to the full manual for instructions on how to drain the water reservoir.
- Seasonal Storage: If storing the unit for an extended period, ensure it is thoroughly cleaned and dried. Drain all water, clean the filter, and store it in a dry, upright position.
7. Troubleshooting
Before contacting customer support, please refer to the following common issues and their solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power, power cord unplugged, circuit breaker tripped. | Check power connection, ensure outlet is functional, reset circuit breaker. |
| Insufficient cooling. | Air filter dirty, exhaust hose not properly installed, room too large, windows/doors open. | Clean air filter, ensure exhaust hose is sealed, close windows/doors, check room size against unit capacity. |
| Unit is noisy. | Unit not on a flat surface, fan speed too high, internal components vibrating. | Ensure unit is on a level surface, reduce fan speed, check for obstructions. |
| Water leakage. | Drain plug open, water tank full (if applicable), unit tilted. | Ensure drain plug is closed, empty water tank, place unit on a level surface. |
If the problem persists after attempting these solutions, please contact SHARP customer support.
8. Specifications
| Feature | Specification |
|---|---|
| Model Number | UL-C09EA-W |
| Cooling Capacity | 2.6 kW / 9,000 BTU |
| Recommended Room Size | Up to 26 sq m |
| Power Consumption | 1,000 W |
| Energy Efficiency Class | A |
| Refrigerant | R290 |
| Voltage | 240 Volt (AC) |
| Noise Level (High/Medium/Low) | 64 / 62 / 60 dB(A) |
| Airflow (High/Medium/Low) | 250 / 230 / 210 m³/hr |
| Operating Temperature Range (Cooling) | 16 to 35 °C |
| Product Dimensions (L x W x H) | 32 x 28.6 x 70 cm |
| Product Weight | 24.5 Kilograms |
| Special Features | LED Display, Sleep Mode, 3 Fan Speeds, Remote Control, Exhaust Pipe & Funnel, Timer Function, Dehumidifier, Auto Restart Memory, Child Lock, Swing Mode |


9. Warranty and Support
Your SHARP UL-C09EA-W Portable Air Conditioner comes with a warranty. Please refer to the included warranty card ("Garantiekarte") for detailed terms and conditions regarding your product's warranty coverage.
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact SHARP customer support. Contact information can typically be found on the warranty card or the official SHARP website.