1. Introduction
Thank you for choosing the Fyearfly ST212 Digital Smart Clamp Meter. This device is a professional, portable measuring instrument designed for electrical testing. It features a 6000-count display and offers multiple functions including AC/DC current, AC/DC voltage, resistance, capacitance, frequency, diode, non-contact voltage (NCV) detection, and live wire identification. Its compact design and comprehensive features make it suitable for various electrical maintenance and testing tasks.

Figure 1: Front view of the Fyearfly ST212 Digital Smart Clamp Meter, showcasing its display and clamp jaw.
2. Safety Information
Please read all safety warnings and operating instructions carefully before using this instrument. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always ensure the meter is in good working condition before use. Do not use if damaged.
- Do not apply voltage or current that exceeds the maximum rated values specified for the meter.
- Exercise extreme caution when working with voltages above 36V DC or 25V AC RMS, as these can pose a shock hazard.
- Ensure the test leads are properly connected and in good condition.
- Do not operate the meter in explosive gas, vapor, or dusty environments.
- Remove the test leads from the circuit before changing functions.
- Replace batteries when the low battery indicator appears to ensure accurate readings.
- Always disconnect power to the circuit and discharge all high-voltage capacitors before measuring resistance, capacitance, or diode.
3. Product Overview
The Fyearfly ST212 clamp meter is designed for ease of use and accuracy. Familiarize yourself with its components:

Figure 2: Labeled components of the ST212 Clamp Meter.
- NCV Induction Zone: Area for non-contact voltage detection.
- Flashlight: Provides illumination for dark work areas.
- NCV/On-off Indicator: Light indicator for NCV detection and power status.
- Trigger: Used to open the clamp jaw.
- Color Display: High-definition screen showing measurement readings and functions.
- Battery Cover: Located on the back for battery access.
- Flashlight/Data Hold Button: Short press to hold data, long press to activate flashlight.
- REL/NCV Button: Short press for Relative measurement, long press for NCV mode.
- Power Button/Function Switch (SEL): Short press to power on/off, long press to cycle through functions within a mode.
- Input Jack (COM, VΩHz, A): Ports for connecting test leads for various measurements.
4. Setup
4.1 Battery Installation
The Fyearfly ST212 requires two AAA batteries for operation.
- Locate the battery cover on the back of the device.
- Use a screwdriver to open the battery cover.
- Insert two AAA batteries, ensuring correct polarity (+/-).
- Securely close the battery cover.
Note: Replace batteries promptly when the low battery indicator appears on the display to maintain measurement accuracy.
5. Operating Instructions
5.1 Power On/Off and Function Selection
- Power On: Short press the SEL button.
- Power Off: Short press the SEL button again. The meter also features an automatic shut-down function if no operation occurs within 15 minutes.
- Function Selection: After powering on, the meter defaults to AUTO mode. Long press the SEL button to cycle through different measurement functions (e.g., Voltage, Resistance, Diode, Capacitance, Frequency).
5.2 AC/DC Current Measurement
To measure AC or DC current:
- Ensure the meter is powered on.
- Press the trigger to open the clamp jaw.
- Enclose a single conductor (not a bundle of wires) with the clamp jaw. Ensure the jaw is fully closed.
- Read the current value on the display. The meter will automatically detect AC or DC current.

Figure 3: Example of measuring DC current in an automotive application using the clamp meter.
5.3 AC/DC Voltage Measurement
To measure AC or DC voltage:
- Connect the red test lead to the VΩHz input jack and the black test lead to the COM input jack.
- Long press the SEL button until the voltage measurement mode is selected (indicated by 'V' or 'mV' on the display).
- Touch the test probes to the points in the circuit where you want to measure voltage.
- Read the voltage value on the display. The meter will automatically detect AC or DC voltage.
5.4 Resistance, Capacitance, Diode, and Frequency Measurement
For these measurements, connect the test leads as described for voltage measurement (red to VΩHz, black to COM).
- Resistance (Ω): Long press SEL to select resistance mode. Touch probes to the component.
- Capacitance (F): Long press SEL to select capacitance mode. Touch probes to the capacitor (ensure it's discharged).
- Diode (►|): Long press SEL to select diode mode. Touch probes across the diode.
- Frequency (Hz): Long press SEL to select frequency mode. Touch probes to the signal source.
5.5 Non-Contact Voltage (NCV) Detection
The NCV function allows for safe detection of AC voltage without direct contact.
- Long press the REL/NCV button to enter NCV mode.
- Move the NCV induction zone (top part of the clamp head) close to the conductor or power outlet.
- If AC voltage is detected, the NCV/On-off indicator light will flash, and an audible alarm will sound. The display will show 'EF'.

Figure 4: Using the NCV function to detect AC voltage near a power outlet.
5.6 Live Wire Identification
This function helps distinguish between live (fire) and neutral (zero) wires.
- Connect the red test lead to the VΩHz input jack and the black test lead to the COM input jack.
- Long press the SEL button until the 'Live' mode is selected.
- Insert the red test lead into the suspected wire's terminal.
- If the red light flashes and a buzzing sound is heard, it indicates a live wire. If there is no flicker and no buzzing sound, it indicates a neutral wire.

Figure 5: Distinguishing between live (firewire) and neutral (zero line) using the Live function.
5.7 Additional Functions
- Data Retention (HOLD): Short press the Flashlight/Data Hold button to freeze the current reading on the display. Press again to release.
- Flashlight: Long press the Flashlight/Data Hold button to turn the flashlight on or off.
- Relative Measurement (REL): Short press the REL/NCV button to enter relative measurement mode. This displays the difference between the current reading and a stored reference value.
- Automatic Shut-down: The meter will automatically power off after approximately 15 minutes of inactivity to conserve battery life.
6. Maintenance
6.1 Cleaning
To clean the meter, wipe the case with a damp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the meter is completely dry before use.
6.2 Battery Replacement
When the low battery indicator appears on the display, replace the batteries immediately to ensure accurate measurements. Refer to Section 4.1 for battery installation instructions.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Meter does not power on. | Dead or incorrectly installed batteries. | Check battery polarity or replace batteries. |
| Inaccurate readings. | Low battery, incorrect function selected, external interference. | Replace batteries, verify function, move away from strong electromagnetic fields. |
| No reading in clamp mode. | Clamp jaw not fully closed, measuring a bundled cable instead of a single conductor. | Ensure jaw is closed and only one conductor is inside. |
| NCV not detecting voltage. | Voltage too low, NCV mode not active. | Ensure NCV mode is active (long press REL/NCV), check for higher voltage source. |
8. Specifications
The following table outlines the technical specifications of the Fyearfly ST212 Digital Smart Clamp Meter:

Figure 6: Detailed Function Parameters including Range, Resolution, and Accuracy.
| Feature | Range | Resolution | Accuracy |
|---|---|---|---|
| AC Voltage | 0.5V~600V | 0.1V | ±(0.8%+5d) |
| AC Voltage (mV) | 0.00mV~600mV | 0.01mV | ±(0.8%+5d) |
| DC Voltage | 0.5V~600V | 0.1V | ±(0.5%+3d) |
| DC Voltage (mV) | 0.00mV~600mV | 0.01mV | ±(0.5%+3d) |
| AC Current | 0.2A~400A | 0.01A~0.1A | ±(2.5%+8d) |
| DC Current | 0.2A~400A | 0.01A~0.1A | ±(2.5%+8d) |
| Resistance | 0Ω~60MΩ | 0.1Ω~0.01MΩ | ±(0.8%+3d) |
| Capacitance | 0nF~60mF | 0.001nF~0.01mF | ±(2.5%+20d) |
| Hertz (Pass A file) | 40Hz~1000Hz | 0.1Hz~1Hz | ±(1.0%+5d) |
| Hertz (Pass V file) | 40Hz~1000Hz | 0.1Hz~1Hz | ±(1.0%+5d) |
| °C Temperature | -40°C~1000°C | 1°C | ±(1.0%+3d) |
| °F Temperature | -40°F~1832°F | 1°F | ±(1.0%+3d) |
| Diode | √ | On-off detection | √ |
| NCV Induction | √ | Zero line of fire | √ |
| Auto Shut-down | √ | Data retention | √ |
| Battery Model | AAA*2 | Weight | 149.2g |
| Product Material | ABS | Jaws open to | 31.5mm/1.24in |
| Max Display | 6000 Counts | Test lead length | 88.5cm/34.8in |
| Screen Display | VA color reverse display screen | Test lead material | PVC/Brass |
| Product Size | 62.1 * 182 * 33.4mm / 2.44 * 7.16 * 1.31in |
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the manufacturer or your point of purchase. Keep your purchase receipt as proof of purchase for any warranty claims.