1. Safety Instructions
Please read all instructions carefully before using the Taurus Magnum 1500W Blender. Retain this manual for future reference.
- Ensure the appliance is unplugged before assembly, disassembly, or cleaning.
- Do not immerse the motor base in water or any other liquid. Clean with a damp cloth only.
- Keep hands and utensils out of the jar while blending to prevent injury and damage to the blades. Use the tamper provided if necessary, only when the lid is securely in place.
- Never operate the blender without the lid properly secured on the jar.
- The blender features a safety system: it will only activate if the glass jar is correctly placed on the motor base. Do not attempt to bypass this safety feature.
- Avoid blending extremely hot liquids, as pressure buildup can cause the lid to eject and result in burns. Allow hot liquids to cool slightly before blending.
- Do not overload the blender. Refer to the capacity limits in the specifications.
- Always place the blender on a stable, flat, and dry surface during operation.
- This appliance is not intended for use by persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
2. Product Overview
The Taurus Magnum 1500W Blender is designed for efficient blending, mixing, and crushing of various ingredients. It features a robust motor and durable components for reliable performance.
Components:
- Motor Base: Contains the powerful 1500W motor and control dial. Features non-slip feet for stability.
- Glass Jar (1.5 Liters): A durable, graduated glass jar with an ergonomic handle and pouring spout.
- Blade Assembly: Features 4 ultra-resistant stainless steel blades, fully detachable for easy cleaning.
- Lid: Securely fits onto the glass jar, with a central filling hole.
- Measuring Cup: Fits into the lid's central opening, allowing for ingredient addition during blending and serving as a measuring tool (up to 50 ml).

Image 2.1: Fully assembled Taurus Magnum 1500W Blender, showcasing its sleek design and main components.
3. Setup
Before first use, wash all removable parts (glass jar, lid, measuring cup, and blade assembly) in warm, soapy water, then rinse and dry thoroughly. The glass jar and blade assembly are dishwasher safe.
- Place the Motor Base: Position the motor base on a clean, dry, and stable countertop. Ensure it is close to a power outlet.
- Assemble the Blade Assembly: Carefully attach the blade assembly to the bottom of the glass jar. Twist until securely locked.
- Place the Jar on the Motor Base: Align the glass jar (with blades attached) onto the motor base. Rotate the jar slightly until it clicks into place, engaging the safety lock mechanism. The blender will not operate if the jar is not correctly seated.
- Add Ingredients: Place your desired ingredients into the glass jar. Do not exceed the maximum fill line (1.5 liters).
- Secure the Lid: Place the lid firmly onto the glass jar. Insert the measuring cup into the central opening of the lid.

Image 3.1: Demonstrates how to detach the blade assembly from the glass jar, a key step for both setup and cleaning.
4. Operating Instructions
Once the blender is assembled and ingredients are added, you can begin blending.
- Connect to Power: Plug the power cord into a suitable electrical outlet.
- Select Speed: Turn the control dial to your desired speed setting. The blender offers 2 speeds for various blending needs.
- Use Turbo/Pulse Function: For maximum power and quick bursts, turn the dial to the 'P' (Pulse/Turbo) setting. This is ideal for crushing ice or achieving very fine textures. Release the dial to stop.
- Blending: Allow the blender to operate until the desired consistency is achieved.
- Adding Ingredients During Blending: If you need to add ingredients while blending, remove the measuring cup from the lid's central opening and carefully add items through the spout. Replace the measuring cup immediately.
- Finish Blending: Once done, turn the control dial to the '0' (Off) position and unplug the appliance from the power outlet.

Image 4.1: Close-up of the control dial, showing the two speed settings and the 'P' for Pulse/Turbo function.

Image 4.2: The blender in action, demonstrating its capability to crush ice effectively.

Image 4.3: A user pouring a blended beverage, highlighting the 1.5L capacity and 1500W power.
5. Cleaning and Maintenance
Regular cleaning ensures optimal performance and extends the life of your blender.
- Unplug the Appliance: Always ensure the blender is unplugged from the power outlet before cleaning.
- Disassemble: Remove the glass jar from the motor base. Carefully detach the blade assembly from the bottom of the jar. Remove the lid and measuring cup.
- Wash Removable Parts: The glass jar, blade assembly, lid, and measuring cup are dishwasher safe. Alternatively, wash them by hand in warm, soapy water. Use a brush to clean around the blades carefully. Rinse thoroughly and dry.
- Clean the Motor Base: Wipe the motor base with a damp cloth. Do not immerse the motor base in water or spray it with liquids. For stubborn stains, use a mild detergent on the cloth. Dry thoroughly.
- Storage: Once all parts are clean and dry, reassemble the blender or store the components separately in a dry place.
6. Troubleshooting
If you encounter issues with your blender, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Blender does not start. | Not plugged in; Jar not correctly seated on motor base; Overload protection activated. | Ensure the power cord is securely plugged in. Check that the glass jar is properly locked onto the motor base. Unplug, remove some ingredients, wait 15 minutes for the motor to cool, then try again. |
| Motor stops during operation. | Overload; Motor overheating. | Turn off and unplug the blender. Remove some ingredients. Allow the motor to cool down for at least 15 minutes before restarting. Ensure you are not exceeding the maximum capacity. |
| Ingredients are not blending smoothly. | Too little liquid; Ingredients are too large; Blades are dull or damaged. | Add more liquid. Cut ingredients into smaller pieces. Use the Pulse/Turbo function for short bursts. If blades appear dull or damaged, contact customer support for replacement. |
| Loud noise or vibration. | Jar not properly seated; Unstable surface; Hard object caught in blades. | Ensure the jar is securely locked onto the motor base. Place the blender on a flat, stable surface. Unplug and carefully check for any foreign objects in the jar or blades. |
7. Specifications
| Feature | Detail |
|---|---|
| Brand | Taurus |
| Model Number | 912462000 |
| Power | 1500 Watts |
| Voltage | 240 Volts (AC) |
| Capacity | 1.5 Liters |
| Material | Stainless Steel (base), Glass (jar) |
| Number of Speeds | 2 + Turbo/Pulse function |
| Blades | 4 ultra-resistant stainless steel blades |
| Dimensions (L x W x H) | 17 x 17 x 38.5 cm |
| Weight | 3.56 Kilograms |
| Special Features | Removable parts, Non-slip feet, Safety lock system |
8. Warranty and Support
Taurus products are manufactured to high-quality standards. This product comes with a standard manufacturer's warranty against defects in materials and workmanship.
For warranty claims, technical support, or spare parts inquiries, please refer to the contact information provided on your purchase receipt or visit the official Taurus website for your region.
Please retain your proof of purchase for any warranty claims.