P PANACARE BSX516

PANACARE Automatic Blood Pressure Monitor

Model: BSX516

Introduction

The PANACARE Automatic Blood Pressure Monitor is designed for accurate and convenient measurement of blood pressure and heart rate at home. This device utilizes advanced measurement technology to provide reliable clinical readings, making it an essential tool for daily health monitoring. It features a large tri-color backlit LCD display, voice reading function, and memory for two users, ensuring ease of use for individuals and families.

PANACARE Blood Pressure Monitor with doctor and patient

Image: The PANACARE Blood Pressure Monitor, recommended by doctors and pharmacists, shown with a healthcare professional and a patient.

PANACARE Blood Pressure Monitor features overview

Image: Overview of the PANACARE Fully Automatic Upper Arm Blood Pressure Monitor's key features, including extra-long cuff, voice broadcast, 2x98 memory sets, irregular heartbeat checking, accuracy, 198 total records, one-touch operation, tri-color backlight, 3.4" large display, and date/time display.

Setup

1. Unpacking the Device

Carefully remove all components from the packaging. The kit includes:

Contents of PANACARE Blood Pressure Monitor package

Image: The complete package contents, including the PANACARE Blood Pressure Monitor, extended cuff, storage bag, and USB charging cable.

2. Powering the Device

The blood pressure monitor can be powered by two methods:

For continuous use, USB power is recommended. If using batteries, ensure they are fresh for accurate readings.

PANACARE Blood Pressure Monitor power options

Image: Illustration of the two power options for the PANACARE Blood Pressure Monitor: 4 AA batteries (not included) and the included USB charging cable.

3. Applying the Cuff

Proper cuff application is crucial for accurate measurements. The adjustable cuff is designed for arm circumferences between 8.7 and 16.5 inches.

  1. Open the Cuff: Open the cuff and pass one end through the iron ring. Ensure the Velcro faces outward.
  2. Position the Cuff: Wrap the cuff around your bare left upper arm. The air tube should run down the center of your arm, aligned with your middle finger. The bottom edge of the cuff should be approximately 2-3 cm (about 1 inch) above your elbow joint.
  3. Secure the Cuff: Tighten the cuff snugly but not too tightly. You should be able to insert one or two fingers between the cuff and your arm.
  4. Arm Position: Rest your arm comfortably on a table or flat surface with your palm facing upwards. Ensure the cuff is at the same level as your heart.
Steps for applying the blood pressure cuff

Image: A visual guide demonstrating the four steps for correctly applying the blood pressure cuff to the upper arm for accurate measurement.

Person demonstrating proper cuff placement

Image: A person demonstrating the correct placement of the adjustable extra-long cuff on the upper arm, highlighting its size range of 8.7-16.5 inches.

Operating Instructions

1. Taking a Measurement

Before measuring, sit quietly for a few minutes. Avoid talking, moving, or eating during the measurement process.

  1. Select User: If using the 2-user memory mode, press the MEM button to switch between User 1 and User 2.
  2. Start Measurement: Press the START/STOP button. The cuff will automatically inflate, and the measurement will begin.
  3. View Results: Once the measurement is complete, the systolic pressure (SYS), diastolic pressure (DIA), and pulse rate (PUL) will be displayed on the large LCD screen. The device will automatically turn off after 30 seconds.
PANACARE Blood Pressure Monitor display showing readings

Image: The PANACARE Blood Pressure Monitor displaying a reading of 120/75 mmHg with a pulse of 80 bpm, along with the tri-color backlight indicators.

2. Understanding the Tri-Color Backlight

The monitor features a tri-color backlit display to visually indicate your blood pressure category according to WHO (World Health Organization) guidelines:

Tri-color backlight indicators for blood pressure levels

Image: Visual representation of the tri-color backlight system, showing green for normal, yellow for mild-medium hypertension, and red for severe hypertension.

3. Voice Reading Function

The device includes an audio reading function, which is particularly useful for the elderly or visually impaired users. You can control this feature using the SET button.

PANACARE Blood Pressure Monitor with voice reading feature

Image: The PANACARE Blood Pressure Monitor demonstrating its voice reading function, announcing blood pressure results aloud.

4. 2-User Memory Mode

The monitor supports two users, each with the capacity to store up to 198 readings, including date and time. This allows for easy tracking of health trends for multiple individuals.

PANACARE Blood Pressure Monitor showing 2-user memory mode

Image: Two PANACARE Blood Pressure Monitors side-by-side, illustrating the 2-user memory mode, allowing separate tracking for two individuals.

5. Setting the Alarm

The device allows you to set an alarm to remind you to measure your blood pressure at a consistent time each day. Refer to the detailed instructions in the included quick start guide for setting the alarm.

Maintenance

1. Cleaning

2. Storage

Troubleshooting

ProblemPossible CauseSolution
No display/Device won't turn onBatteries are dead or incorrectly inserted; USB cable not connected properly.Replace batteries with new ones, ensuring correct polarity. Check USB cable connection.
Inaccurate readingsImproper cuff placement; movement or talking during measurement; incorrect arm position; recent physical activity.Ensure cuff is correctly applied and positioned at heart level. Remain still and silent during measurement. Rest for 5 minutes before measuring.
Cuff does not inflate or inflates too little/muchAir tube disconnected; cuff not properly secured; cuff size mismatch.Check that the air tube is securely connected to the monitor. Re-apply the cuff snugly. Ensure cuff size is appropriate for your arm (8.7-16.5 inches).
Irregular Heartbeat Indicator appearsDetection of an irregular heartbeat during measurement.This indicates an irregular heartbeat was detected. If this occurs frequently, consult a healthcare professional.

Note: This device is for home use and monitoring purposes only. It is not a substitute for professional medical advice or diagnosis. Always consult your doctor for any health concerns.

Specifications

Detailed size and display information for PANACARE Blood Pressure Monitor

Image: Detailed diagram showing the dimensions of the PANACARE Blood Pressure Monitor and cuff, along with labels for display elements like Systolic, Diastolic, and Pulse.

FeatureDetail
BrandP PANACARE
Model NumberBSX516
Display TypeLCD with Tri-Color Backlight
Power Source4 AA Batteries (not included) or USB Powered
Cuff SizeAdjustable, 8.7-16.5 inches (22-42 cm)
Memory Capacity2 Users, 198 readings per user (total 396) with date and time
Voice FunctionYes (toggle on/off)
Irregular Heartbeat DetectionYes
Automatic Shut-offYes (after 30 seconds of inactivity)
Product Dimensions13L x 11W x 5.8Th centimetres (Monitor)
Item Weight15.52 Ounces (approx. 440g)

Warranty and Support

The PANACARE Automatic Blood Pressure Monitor comes with a 12-month warranty from the date of purchase.

Our professional customer service team is available 24/7 to assist you with any questions or issues you may encounter. If you have any inquiries about your blood pressure monitor, please contact us directly. We aim to respond within 24 hours to ensure a satisfactory experience.

For support, please refer to the contact information provided in your product packaging or visit the official PANACARE website.

Related Documents - BSX516

Preview GIMA AOJ-33A Arm Blood Pressure Monitor User Manual
User manual for the GIMA AOJ-33A Arm Blood Pressure Monitor, detailing its features, intended use, contraindications, operation, maintenance, troubleshooting, and technical specifications. This device uses the oscillometric method for accurate blood pressure and pulse rate measurement at home or in medical facilities.
Preview Sinocare BSX516 Blood Pressure Monitor User Manual
Comprehensive guide for the Sinocare BSX516 Blood Pressure Monitor, detailing setup, operation, measurement methods, and troubleshooting for accurate home blood pressure monitoring.
Preview GLUCOCARD Shine XL Blood Glucose Monitoring System User Guide
A comprehensive guide to using the GLUCOCARD Shine XL blood glucose monitoring system. Learn step-by-step instructions for accurate blood glucose testing, including preparation, sample collection, reading results, and safe disposal of materials.
Preview Nellcor Puritan Bennett NPB-3900 Patient Monitor Service Manual - Technical Guide
Comprehensive service manual for the Nellcor Puritan Bennett NPB-3900 Patient Monitor. Covers maintenance, performance verification, troubleshooting, disassembly, specifications, and technical details for this medical monitoring device.
Preview Misuratore di Pressione da Braccio Smart Laica KD-926: Istruzioni e Garanzia
Manuale completo per il misuratore di pressione da braccio smart Laica KD-926. Include istruzioni d'uso, avvertenze di sicurezza, classificazione dei valori pressori, descrizione del prodotto, manutenzione, risoluzione problemi, garanzia e specifiche tecniche.
Preview GLUCOCARD Shine Connex Blood Glucose Monitoring System Instructions
A comprehensive guide to using the GLUCOCARD Shine Connex Blood Glucose Monitoring System, covering setup, blood sample collection, testing, and proper disposal.