1. Introduction

The CEM DT-8806 Digital Thermometer is a non-contact infrared thermometer designed for accurate and hygienic temperature measurement. It is suitable for use with adults, children, and infants, offering both body and surface temperature modes. This manual provides essential information for the safe and effective use of your device.

Key Features:

  • No-Contact Measurement: Reduces cross-infection risk.
  • Dual Mode: Measures both body and surface temperatures.
  • Fast Readings: Provides instant accuracy.
  • Fever Alarm: Visual and audible alerts for high temperatures.
  • Memory Recall: Stores up to 32 temperature readings.
  • Switchable Units: Easily switch between Fahrenheit (°F) and Celsius (°C).
  • Large LCD Display: Clear readings day and night.
CEM DT-8806 thermometer displaying key features like instant measurement, non-contact, auto-off, fever alarm, memory function, low battery indication, backlit display, silent mode, and Celsius/Fahrenheit switchable.

Figure 1: Overview of CEM DT-8806 Key Features.

2. Product Components

Your CEM DT-8806 Digital Thermometer package includes the following items:

  • CEM DT-8806 Digital Thermometer Unit
  • User Manual (this document)
  • 2 x 1.5V AAA Batteries
  • Carrying Case / Gift Box
Contents of the CEM DT-8806 package, including the purple and white thermometer, its retail box, a user manual, a purple carrying pouch, and two AAA batteries.

Figure 2: Package Contents of the CEM DT-8806 Digital Thermometer.

3. Setup

3.1 Battery Installation

  1. Locate the battery cover at the bottom of the thermometer handle.
  2. Slide the battery cover downwards to open the compartment.
  3. Insert two 1.5V AAA batteries, ensuring correct polarity (+ and -).
  4. Close the battery cover by sliding it upwards until it clicks into place.

Note: If the low battery symbol appears on the display, replace the batteries promptly to ensure accurate readings.

A CEM DT-8806 thermometer showing a low battery icon on its display, indicating the need for battery replacement.

Figure 3: Low Battery Indication on the Thermometer Display.

4. Operating Instructions

4.1 Basic Operation

  1. Point the thermometer at the center of the forehead from a distance of 1cm to 5cm (0.39in to 2.0in).
  2. Press the measurement trigger button to take a reading.
  3. The temperature will be displayed on the LCD screen within 1 second.
A hand holding the CEM DT-8806 thermometer, pointing it at a baby's forehead from a short distance to take a non-contact temperature reading.

Figure 4: Proper Measurement Distance for Non-Contact Forehead Temperature.

4.2 Mode Selection (Body / Surface)

The DT-8806 thermometer supports two measurement modes: Body Mode and Surface Mode. Press the MODE button to switch between these modes.

  • Body Mode: Used for measuring human body temperature. The display will show "Body".
  • Surface Mode: Used for measuring the surface temperature of objects, such as milk, bathwater, or room temperature. The display will show "Surface Temp".
Two images side-by-side. On the left, a hand measures the temperature of milk in a glass (Surface mode: 32°F to 140°F). On the right, a hand measures a baby's forehead temperature (Body mode: 89.6°F to 108.5°F).

Figure 5: Body Mode vs. Surface Mode Measurement Examples.

Video 1: Demonstrating the CEM DT-8806's features, including button functions, IR sensor, measurement trigger, and switching between Body and Surface modes for various applications. This video highlights the versatility and ease of use of the thermometer.

4.3 Temperature Unit Switching (°F / °C)

To switch between Fahrenheit (°F) and Celsius (°C), press and hold the MODE button for approximately 3 seconds until the unit changes on the display.

Two images of the CEM DT-8806 thermometer side-by-side, one displaying temperature in Celsius (36.6°C) and the other in Fahrenheit (98.6°F), with an arrow indicating the switch function.

Figure 6: Switching Between Fahrenheit and Celsius Temperature Units.

4.4 Memory Function

The thermometer can store up to 32 sets of temperature readings. To access the memory, press the UP or DOWN buttons when the device is on. This allows you to track historical temperature changes.

A graph showing temperature readings over 25 times, illustrating the 32-set memory function of the CEM DT-8806 thermometer, with a hand holding the thermometer in the foreground.

Figure 7: Tracking Temperature Changes with the 32-Set Memory Function.

4.5 Fever Alarm

The thermometer features a fever alarm. If the measured body temperature exceeds the preset threshold (default is 38°C or 100.4°F), the display backlight will change color (e.g., to red) and an audible "didi" sound will be emitted to alert you of a potential fever.

4.6 Silent Mode

The thermometer can be switched to silent mode to avoid disturbing sleeping individuals, especially babies. Refer to the device's buttons for the specific sequence to activate/deactivate silent mode (often by pressing and holding the "Up" or "Down" button).

5. Maintenance

5.1 Cleaning

  • Use a soft, dry cloth to clean the thermometer body.
  • For the infrared sensor lens, gently wipe with a cotton swab lightly moistened with alcohol. Do not use abrasive cleaners or immerse the device in water.
  • Ensure the device is completely dry before storage or next use.

5.2 Storage

  • Store the thermometer in a cool, dry place, away from direct sunlight and extreme temperatures.
  • If the thermometer will not be used for an extended period, remove the batteries to prevent leakage and damage to the device.

6. Troubleshooting

Refer to the table below for common issues and their solutions:

ProblemPossible CauseSolution
No display / Device won't turn onDead or incorrectly installed batteries.Replace batteries with new 1.5V AAA batteries, ensuring correct polarity.
Inaccurate readingsIncorrect measurement distance; dirty sensor lens; ambient temperature fluctuations.Ensure proper distance (1-5cm). Clean the IR sensor. Allow thermometer to acclimatize to room temperature for 15-20 minutes before use.
"Lo" or "Hi" displayedTemperature is outside the measurable range.Ensure the thermometer is in the correct mode (Body/Surface) and the temperature is within the specified range.
No sound from fever alarmSilent mode is activated.Deactivate silent mode (refer to section 4.6).

7. Specifications

FeatureDetail
Model NumberDT-8806S
Measurement Range (Body Mode)89.6°F to 108.5°F (32.0°C to 42.5°C)
Measurement Range (Surface Mode)32°F to 140°F (0°C to 60°C)
Accuracy±0.4°F (±0.2°C) for Body Mode; ±1.8°F (±1.0°C) for Surface Mode
Measurement Distance1cm ~ 5cm (0.39in ~ 2.0in)
Response Time1 second
Memory Storage32 sets of readings
Power SupplyDC 3V (2 x AAA batteries)
Automatic Shut-offApproximately 30 seconds
Dimensions5.55 x 4.21 x 2.05 inches (approximate)
Weight5.61 ounces (approximate, without batteries)
CertificationsCE, FDA, FCC, RoHS
A CEM DT-8806 thermometer with dimensions labeled: 2.55 inches width, 4.92 inches height, and 0.98 inches depth.

Figure 8: Approximate Dimensions of the CEM DT-8806 Thermometer.

8. Warranty and Support

For warranty information and technical support, please refer to the contact details provided on the product packaging or visit the official CEM Instrument website. Keep your purchase receipt as proof of purchase for any warranty claims.

CEM is committed to providing reliable products and customer satisfaction. If you encounter any issues not covered in this manual, please contact our customer service team for assistance.

Related Documents - DT-8806S

Preview CEM DT-612 Digital Thermometer - Technical Specifications and Features
Detailed information on the CEM DT-612 digital thermometer, including its electrical and environmental specifications, features, and accessories. This portable device uses K-type thermocouples for accurate temperature measurements.
Preview CEM Coating Thickness Gauge Pro DT-156H User Manual
Comprehensive user manual for the CEM Coating Thickness Gauge Pro (DT-156H). Covers general information, features, specifications, operation, calibration, settings, troubleshooting, and more.
Preview CEM DT-9680 Particle Mass Concentration Detector User Manual
User manual for the CEM DT-9680 Air Quality Detector. Learn about its features, specifications, operation, settings, and air quality standards for detecting PM2.5, PM10, CO2, HCHO, and TVOC.
Preview CEM DT-171 Humidity and Temperature USB Datalogger User Guide
Comprehensive user guide for the CEM DT-171 Humidity and Temperature USB Datalogger. Details features, specifications, LED status indicators, battery replacement, and sensor reconditioning procedures.
Preview CEM DT-90 Thermo-Anemometer User Manual - Air Velocity & Temperature Measurement
Detailed user manual for the CEM DT-90 Thermo-Anemometer. Learn about its features, specifications, operation, and maintenance for accurate air velocity and temperature measurements.
Preview Инструкция по эксплуатации электроизмерительных клещей CEM DT-3348
Подробная инструкция по эксплуатации цифровых токовых клещей CEM DT-3348, охватывающая меры безопасности, описание устройства, процедуры измерений и обслуживание.