1. Introduction
The SINOTIMER TM617 is a versatile digital programmable timer switch designed to automate the control of various electrical devices. It allows for precise scheduling of ON/OFF cycles over a 7-day period, making it suitable for a wide range of applications. This manual provides detailed instructions for the installation, operation, and maintenance of your TM617 timer switch.
Common applications include controlling street lights, neon signs, lamps, water heaters, air conditioners, billboards, electric ovens, boosters, sprayers, fillers, preheaters, agricultural equipment, and broadcasting equipment. The device features a built-in battery to preserve program settings during power interruptions, ensuring reliable operation. It is characterized by low power consumption, a high-precision CMOS chip, strong anti-interference capabilities, and user-friendly programming. The TM617 is IEC 60367 and CE certified.
2. Product Features
- Ideal for household and industrial applications, suitable for panel mounting.
- High load capacity: Supports up to 3500 Watts / 16 Amps with 1NO+1NC contact configuration.
- Flexible programming: Features 24-hour / 7-day weekly programming capabilities.
- Memory retention: Integrated rechargeable battery ensures program settings are saved during power outages.
- Accuracy: Automatic error correction of +/- 30 seconds per week.
- Multiple programs: Offers 16 ON/OFF program settings with repeat function.
- Manual control: Includes a manual ON/OFF override function.
- Clear display: Large LCD for easy viewing of time and program status.
3. Technical Specifications
| Model | TM-617 |
| Temperature Range | -20 °C to +50 °C |
| Power Supply | 100-130 V AC (Note: 220V variant also available) |
| Power Consumption | 4.5 VA (MAX) |
| Display | LCD |
| Switching Contact | 1 Changeover Switch (1NO+1NC) |
| Programs | 16 ON/OFF settings per day or week |
| Hysteresis | 2 seconds/day (at 25°C) |
| Minimum Interval | 1 minute |
| Switching Capacity | 16 (8) A, 250 V AC |
| Memory Backup | 60 days (via internal battery) |
| Timer Range | 1 minute to 168 hours |
| Internal Battery | 1.2 V, 40 mA |
| Average Error | ±1 second/24 hours (at 25°C) |
4. Setup and Installation
Safety Warning: Installation should only be performed by a qualified electrician. Ensure power is disconnected before installation to prevent electric shock.
4.1 Unpacking and Inspection
Carefully remove the TM617 timer switch from its packaging. Inspect the device for any signs of damage. The package should include the timer switch and mounting screws.

Figure 1: The SINOTIMER TM617 Digital Time Switch with its protective cover open, revealing the display and buttons. Two mounting screws are shown next to the device, indicating included accessories for installation.
4.2 Mounting
The TM617 is designed for panel mounting. Use the provided screws to secure the timer switch to a suitable panel or enclosure. Ensure adequate ventilation around the device.

Figure 2: Rear view of the SINOTIMER TM617 Digital Time Switch, illustrating the mounting points and terminal block for electrical connections. This view is crucial for proper installation.
4.3 Wiring Diagram
Refer to the wiring diagram below for correct electrical connections. Ensure all connections are secure and comply with local electrical codes.

Figure 3: Technical drawing of the SINOTIMER TM617 Digital Time Switch, showing its dimensions (72mm x 72mm x 48mm) and an exploded view. The diagram also includes a basic wiring schematic, indicating where to connect the power input and load output.
The diagram typically shows terminals for power input (L, N) and load output (L, N, or switched live). The TM617 has a 1NO+1NC contact, meaning it can switch between two states. Consult the markings on the device for specific terminal assignments.
5. Operating Instructions
The TM617 features an intuitive button layout for setting the time and programming schedules.

Figure 4: Front view of the SINOTIMER TM617 Digital Time Switch, highlighting the LCD display and the various control buttons for setting time and programming functions.
5.1 Button Functions
- Clock Icon: Used to set the current time and day.
- P: Program button, used to enter and navigate through programming modes.
- D+: Day button, used to adjust the day of the week.
- H+: Hour button, used to adjust the hour.
- M+: Minute button, used to adjust the minute.
- C/R: Cancel/Recall or Reset button. Press to clear settings or reset the device.
- Hand Icon: Manual override button, to switch the output ON/OFF manually, overriding current program.
5.2 Initial Setup and Reset
Upon first use or after a prolonged power outage, the display may be blank or show incorrect time. Press the C/R button (often recessed, requiring a pointed object) to reset the device. The internal battery will charge once power is supplied to the unit.
5.3 Setting Current Time and Day
- Press and hold the Clock Icon button.
- While holding the Clock Icon button, press D+ to set the current day of the week.
- While holding the Clock Icon button, press H+ to set the current hour.
- While holding the Clock Icon button, press M+ to set the current minute.
- Release the Clock Icon button. The time is now set.
5.4 Programming ON/OFF Cycles
The TM617 allows for up to 16 ON/OFF programs. Each program consists of an ON time and an OFF time, and can be set for specific days or groups of days.
- Press the P button once to enter program setting mode. The display will show "1 ON".
- Press D+ to select the desired day(s) for this program. Options typically include individual days (MO, TU, WE, etc.), weekdays (MO TU WE TH FR), weekends (SA SU), or all days (MO TU WE TH FR SA SU).
- Press H+ to set the ON hour.
- Press M+ to set the ON minute.
- Press the P button again. The display will show "1 OFF".
- Repeat steps 2-4 to set the OFF time for the first program.
- Press the P button again to move to the next program ("2 ON"). Repeat the process for up to 16 programs.
- To exit program setting mode and return to the current time display, press the Clock Icon button.
5.5 Manual Override
Press the Hand Icon button to manually switch the output state (ON/OFF) without affecting the programmed schedule. This is useful for temporary control. The display will indicate the manual override status (e.g., "ON" or "OFF" with a hand icon).
6. Maintenance
The SINOTIMER TM617 is designed for low maintenance. Follow these guidelines to ensure optimal performance:
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Battery: The internal rechargeable battery is designed for long life and typically does not require replacement. It charges automatically when the device is powered. If the display remains blank after power is restored, allow some time for the battery to charge.
- Environment: Ensure the operating environment stays within the specified temperature range (-20 °C to +50 °C) and is free from excessive dust or moisture.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Display is blank. | No power supply; internal battery discharged. | Check power connections. Ensure the device is receiving power. Allow time for the internal battery to charge. Press the C/R button to reset. |
| Timer does not switch ON/OFF as programmed. | Incorrect program settings; manual override active; incorrect current time/day. | Verify program settings (ON/OFF times, days). Check if manual override is active and switch to AUTO mode if necessary. Ensure current time and day are set correctly. |
| Time is inaccurate. | Minor drift (normal for electronic timers); device needs reset. | The device has an automatic error correction of +/- 30 seconds per week. If significantly off, reset the device using the C/R button and re-set the current time. |
| Load does not turn ON/OFF. | Incorrect wiring; faulty load; timer malfunction. | Check wiring according to the diagram. Test the load directly to ensure it is functional. If all else fails, the timer may be faulty and require replacement. |
8. Safety Information
- Always disconnect power before installing, wiring, or servicing the device.
- Do not exceed the maximum load capacity of 16A / 3500W.
- Ensure proper grounding and adherence to all local electrical codes.
- Do not expose the device to water or extreme humidity.
- Do not attempt to open or repair the device yourself. Refer to qualified personnel.
- Keep out of reach of children.
9. Warranty and Support
For warranty information and technical support, please refer to the purchase documentation or contact your retailer. SINOTIMER products are designed for reliability, and support is available for any operational issues or defects.
For further assistance, you may visit the SINOTIMER Brand Store on Amazon.