1. Introduction
Thank you for choosing the TOTAL TMT460013 Digital Multimeter. This device is designed for safe and accurate measurement of various electrical parameters, including AC/DC voltage, DC current, resistance, and continuity. It is an essential tool for electricians, technicians, and hobbyists for electrical testing and troubleshooting. Please read this manual thoroughly before use to ensure proper operation and safety.
2. Safety Information
Always adhere to basic safety precautions when using this multimeter to reduce the risk of fire, electric shock, or personal injury. Failure to follow these instructions can result in severe injury or damage to the device.
- Do not exceed the maximum input values specified for each measurement range.
- Do not use the multimeter if it appears damaged or if the test leads are compromised.
- Always ensure the test leads are correctly connected to the appropriate input jacks for the desired measurement.
- Never attempt to measure voltage on a circuit with the function switch set to current, resistance, or continuity mode.
- Be cautious when working with voltages above 30V AC RMS, 42V peak, or 60V DC, as these pose a shock hazard.
- Remove the test leads from the circuit before changing the function switch position.
- Replace the battery immediately when the low battery indicator appears to ensure accurate readings.
- Adhere to local and national safety codes.
3. Product Overview
The TOTAL TMT460013 Digital Multimeter is a compact and robust device designed for various electrical measurements. Its intuitive interface and clear display make it easy to use for both professionals and DIY enthusiasts.

Figure 1: Front view of the TOTAL TMT460013 Digital Multimeter, showing the LCD display, function buttons, and input terminals.
Controls and Display
- LCD Display: Shows measurement readings, units, and function indicators.
- Power Button (Red): Press to turn the multimeter ON or OFF.
- SMART FUNC Button (Green): Cycles through different measurement functions within a mode (e.g., AC/DC voltage, resistance/continuity).
- HOLD Button (Blue): Freezes the current reading on the display. Press again to release.
- Input Jacks: Terminals for connecting test leads (COM, VΩmA).
4. Setup
4.1 Battery Installation
The multimeter is powered by internal batteries. Ensure batteries are correctly installed before first use or when replacing them.
- Turn off the multimeter by pressing the Power button.
- Locate the battery compartment cover on the back of the unit.
- Use a screwdriver to loosen the screw(s) securing the cover.
- Remove the cover and insert the batteries, observing correct polarity (+ and -).
- Replace the battery compartment cover and tighten the screw(s).
4.2 Connecting Test Leads
Proper connection of test leads is crucial for accurate and safe measurements.
- Insert the black test lead into the COM (Common) input jack.
- Insert the red test lead into the VΩmA input jack for voltage, resistance, or current measurements.
- Ensure connections are firm before proceeding with any measurements.
5. Operating Instructions
5.1 Powering On/Off
Press the red Power button once to turn the multimeter ON. Press and hold the Power button for a few seconds to turn it OFF.
5.2 Selecting Measurement Functions
The TMT460013 features an auto-ranging function, simplifying measurement selection. The device will automatically detect the type of measurement (AC/DC voltage, resistance, continuity) when the leads are connected. Use the SMART FUNC button to cycle between specific functions if needed (e.g., between AC and DC voltage, or resistance and continuity).
5.3 Taking Measurements
- Voltage Measurement (AC/DC):
Connect the test leads in parallel to the circuit or component you wish to measure. The multimeter will automatically detect AC or DC voltage. - Resistance Measurement:
Ensure the circuit is de-energized before measuring resistance. Connect the test leads across the component. - Continuity Test:
Ensure the circuit is de-energized. Connect the test leads across the component or wire. A low resistance (typically less than 50Ω) will indicate continuity, often accompanied by an audible beep. - DC Current Measurement:
WARNING: To measure current, the multimeter must be connected in series with the circuit. Ensure the circuit is de-energized before connecting the multimeter. Break the circuit, then connect the red lead to the higher potential side and the black lead to the lower potential side.
5.4 Data Hold Function
Press the blue HOLD button to freeze the current reading on the display. This is useful for recording measurements in difficult-to-read locations. Press the button again to release the hold and resume live readings.
6. Maintenance
6.1 Cleaning
Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is completely dry before use.
6.2 Battery Replacement
When the low battery indicator appears on the display, replace the batteries as described in Section 4.1. Always use the specified battery type.
6.3 Storage
If the multimeter is not used for an extended period, remove the batteries to prevent leakage and damage. Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
7. Troubleshooting
Refer to the table below for common issues and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| No display or dim display | Low or dead batteries; Incorrect battery installation | Replace batteries; Check battery polarity |
| Incorrect readings | Incorrect function selected; Poor test lead connection; Damaged test leads | Ensure correct function; Check lead connections; Replace damaged leads |
| No continuity beep | Circuit not continuous; Multimeter not in continuity mode | Check circuit for breaks; Select continuity function using SMART FUNC button |
| Multimeter does not respond | Internal fault; Completely drained battery | Replace batteries; Contact customer support if issue persists |
8. Specifications
Key technical specifications for the TOTAL TMT460013 Digital Multimeter.
| Feature | Detail |
|---|---|
| Manufacturer | Total |
| Model Number | TMT460013 |
| Measurement Type | Multimeter |
| Power Source | Battery Powered |
| Item Weight | 209 g (0.21 Kilograms) |
| Product Dimensions | 10 x 20 x 37 cm |
| Color | Turquoise |
| Safety Standards | UL 61010-1, IEC 61010-2-030 |
| ASIN | B09QZWHFNR |
| GTIN | 06941639846475 |
9. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official TOTAL Tools website. Keep your purchase receipt as proof of purchase for any warranty claims.