1. Introduction

The Versonel Nightwatcher VSL90 is an advanced outdoor LED floodlight designed for security and deterrence. It features a patented robotic motion sensor that tracks movement across a wide detection zone, illuminating and following any detected activity. This manual provides essential information for the safe and effective installation, operation, and maintenance of your Nightwatcher VSL90.

2. Safety Information

Please read all instructions carefully before installation and use. Failure to follow these instructions may result in electric shock, fire, or other hazards.

3. Package Contents

Verify that all components are present before beginning installation:

4. Product Overview

The Versonel Nightwatcher VSL90 integrates a powerful LED floodlight with a sophisticated motion detection and tracking system.

Front view of the Versonel Nightwatcher VSL90 LED Floodlight

Figure 4.1: Front view of the VSL90 light fixture, showing the LED panel and the spherical PIR sensor below.

Side view of the Versonel Nightwatcher VSL90 LED Floodlight with control panel

Figure 4.2: Side view of the VSL90, illustrating the adjustable light head and the integrated control panel on the side.

The unit features a 1700 Lumen LED light source and three integrated Passive Infrared (PIR) sensor zones. These sensors detect movement up to 39.37 feet (12 meters) across a 210-degree horizontal detection zone. Upon detection, the light automatically rotates to follow the movement, illuminating the area and creating the impression of being watched.

Diagram showing the 210-degree motion detection zone of the VSL90

Figure 4.3: Illustration of the VSL90's 210-degree detection zone and range, covering a wide area around a property.

Illustration of the VSL90 light tracking a person's movement

Figure 4.4: Visual representation of the VSL90's robotic movement tracking feature, where the light follows detected motion.

5. Setup and Installation

The VSL90 is designed for easy outdoor installation, replacing an existing floodlight fixture or adding to any location with electrical wiring. This unit must be hardwired.

5.1. Pre-Installation Steps

  1. Disconnect Power: Turn off power to the installation area at the circuit breaker.
  2. Prepare Junction Box: Ensure you have a suitable 4-inch diameter electrical junction box (not included) for mounting.
  3. Unpack: Carefully remove all components from the packaging.

5.2. Mounting Instructions

Detailed diagram for installing the Versonel Nightwatcher VSL90

Figure 5.1: Exploded view of the VSL90 installation components and wiring connections.

  1. Attach Universal Mounting Bracket (E): Secure the universal mounting bracket to your electrical junction box using the provided junction box mounting screws (D). Ensure the bracket is oriented correctly.
  2. Install EVA Gasket (F): Place the EVA gasket over the universal mounting bracket. This helps seal the fixture against moisture.
  3. Wire Connections (G): Connect the household wiring to the light fixture wiring using the provided wire nuts (G). Typically, this involves connecting live to live, neutral to neutral, and ground to ground. Refer to local electrical codes.
  4. Mount Light Fixture (A): Align the light fixture with the mounting bracket and secure it using the light fixture mounting screws (C).
  5. Attach Decorative Screw Covers (B): Place the decorative screw covers over the mounting screws for a finished appearance.
  6. Restore Power: Once installation is complete and all connections are secure, restore power at the circuit breaker.

6. Operating Instructions

The VSL90 features a control panel with four switches (SW1-SW4) to adjust its operation. The LEDs (1-4) indicate the current settings.

Close-up of the Versonel Nightwatcher VSL90 control panel with four switches and LED indicators

Figure 6.1: Detailed view of the VSL90's control panel, showing the four switches (SW1-SW4) and their corresponding functions.

6.1. Control Panel Functions

6.2. Initial Setup and Testing

  1. After installation, set SW1 to 'M', SW2 to 'On', and SW3 to 'On'.
  2. Activate 'Walk Test' (SW4) and walk through the intended detection area to ensure the sensor covers the desired zones and the light tracks your movement.
  3. Adjust SW1 (Sensor Sensitivity) as needed to optimize detection range and minimize false triggers.
  4. Once satisfied with the coverage, deactivate 'Walk Test' (SW4). The unit will now operate in its normal mode.

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your Nightwatcher VSL90.

8. Troubleshooting

Refer to the following table for common issues and their solutions:

ProblemPossible CauseSolution
Light does not turn on.No power; SW2 is Off; Sensor sensitivity too low; Faulty wiring.Check circuit breaker; Ensure SW2 is On; Adjust SW1 to 'M' or 'H'; Verify wiring connections.
Light does not track movement.SW3 is Off; Obstruction in sensor view; Sensor malfunction.Ensure SW3 is On; Clear any obstructions; Perform a 'Walk Test' (SW4).
Light turns on or tracks without apparent motion (false triggers).Sensor sensitivity too high; Heat sources (e.g., car engines, vents); Small animals; Moving foliage.Adjust SW1 to 'L' or 'M'; Reposition the fixture to avoid heat sources or moving objects.
Light stays on continuously.Continuous motion in detection zone; Faulty sensor.Ensure no constant motion is present; Power cycle the unit. If issue persists, contact support.

9. Specifications

10. Warranty Information

This product is covered by a manufacturer's warranty. Please refer to the warranty card included with your product packaging or visit the official Versonel website for detailed warranty terms and conditions. Keep your purchase receipt as proof of purchase for any warranty claims.

11. Support

For technical assistance, troubleshooting beyond this manual, or inquiries regarding your Versonel Nightwatcher VSL90, please contact Versonel customer support. Contact information can typically be found on the product packaging or the official Versonel brand website.

Related Documents - VSL90

Preview Versonel VSL90 LED Security Light Quick Installation Guide
Comprehensive guide for installing the Versonel VSL90 motion-activated LED security light, covering parts, wiring, mounting, and testing procedures.
Preview Versonel VSL95 LED Security Light Quick Installation Guide
Step-by-step instructions for installing and connecting the Versonel VSL95 LED security light to your Wi-Fi network using the Tuya Smart app.
Preview Versonel VSLPC60 Electric Pressure Cooker User Manual and Safety Guide
Comprehensive user manual for the Versonel VSLPC60 Electric Pressure Cooker, covering important safeguards, specifications, operating instructions, cooking examples, maintenance, and troubleshooting.