1. Product Overview

The SYNLETT Wireless Call Buttons are designed to provide a reliable and efficient communication solution for various settings, including home care, clinics, restaurants, and other service environments. This package includes five individual call buttons, each capable of sending a signal to a compatible SYNLETT central monitoring unit (sold separately).

Five black SYNLETT wireless call buttons arranged in a grid, each with a grey center featuring a bell icon and the word 'CALL'.

Image: Five SYNLETT wireless call buttons. Each button is black with a grey circular center, featuring a bell icon and the word 'CALL'. These buttons are designed for easy activation to signal for assistance.

Package Contents:

2. Setup and Installation

2.1 Battery Installation

Each call button requires one 12V 23A battery for operation. If batteries are not pre-installed, follow these steps:

  1. Gently twist the back cover of the call button counter-clockwise to open it.
  2. Insert the 12V 23A battery into the battery compartment, ensuring the positive (+) and negative (-) terminals are correctly aligned.
  3. Replace the back cover by aligning the tabs and twisting clockwise until it clicks securely into place.
Inside view of a SYNLETT call button showing the circuit board and a 12V 23A battery inserted.

Image: Internal view of a SYNLETT call button, displaying the circuit board and the correct placement of the 12V 23A battery. This illustrates how to access the battery compartment for installation or replacement.

2.2 Pairing with Central Monitoring Unit

The SYNLETT Wireless Call Buttons are designed to work exclusively with the SYNLETT Q034G-F007 central monitoring unit. Each button must be programmed or paired with the monitoring unit before it can function correctly. Refer to the instruction manual of your SYNLETT Q034G-F007 central monitoring unit for detailed pairing instructions.

2.3 Mounting Options

Each call button comes with a versatile mounting bracket, allowing for multiple installation methods:

Diagram showing three ways to mount the SYNLETT call button: with a lanyard strap, by screwing into a wall, and using an adhesive patch.

Image: This visual guide demonstrates the three primary methods for deploying the SYNLETT call button: wearing it with a lanyard for personal mobility, securing it to a wall with screws for fixed locations, or attaching it with an adhesive patch for flexible placement on smooth surfaces.

Detailed images showing how to apply adhesive tape to the mounting bracket and how to use screws for wall mounting.

Image: Close-up instructions for mounting the call button. The top panel shows the application of double-sided adhesive tape to the back of the mounting bracket. The bottom panel illustrates how to secure the bracket to a surface using screws, highlighting the attachment points.

3. Operating Instructions

Once the call buttons are set up and paired with the central monitoring unit, operation is straightforward:

  1. To initiate a call, simply press the large 'CALL' button located in the center of the device.
  2. Upon pressing, the button will send a wireless signal to the paired SYNLETT Q034G-F007 central monitoring unit.
  3. The central monitoring unit will then display the call number and typically emit an audible alert, notifying staff or caregivers of the request for assistance.

Applications:

These wireless call buttons are versatile and can be used in various environments:

Diagram illustrating the use of the wireless call system in healthcare and hospitality settings.

Image: A comprehensive diagram showcasing the application of the SYNLETT wireless call system in two distinct environments. The top section depicts its use in a healthcare setting, with a patient using the call button to alert a nurse. The bottom section illustrates its utility in a hospitality environment, where a customer presses the button to request service from restaurant staff. Both scenarios highlight the seamless communication facilitated by the system.

4. Maintenance

4.1 Battery Replacement

When the call button's signal becomes weak or it stops responding, it is likely time to replace the 12V 23A battery. Follow the battery installation steps outlined in Section 2.1 to replace the battery. Dispose of old batteries responsibly according to local regulations.

4.2 Cleaning

To clean the call buttons, gently wipe the surface with a soft, slightly damp cloth. Do not use abrasive cleaners, solvents, or immerse the device in water, as this can damage the internal components.

4.3 Storage

Store the call buttons in a cool, dry place away from direct sunlight and extreme temperatures. If storing for an extended period, it is recommended to remove the batteries to prevent leakage.

5. Troubleshooting

If you continue to experience issues after following these troubleshooting steps, please contact SYNLETT customer support for further assistance.

6. Specifications

BrandSYNLETT
Model NumberF007B(5)
Power Source12V 23A Battery (Alkaline)
Special FeaturesPush-button call
Product Dimensions (per button)5.51 x 5.51 x 2.11 cm (approx.)
Product Weight (total for 5 buttons)304 g (approx.)

7. Warranty and Support

For information regarding product warranty, returns, or technical support, please refer to your purchase documentation or contact the seller directly. SYNLETT offers solutions designed to enhance care and service, and we are committed to supporting our products.

Please note that additional protection plans may be available from third-party providers at the time of purchase. These plans are separate from the manufacturer's warranty.

For general inquiries or to explore other SYNLETT products, visit the official SYNLETT brand store or website.

Related Documents - F007B(5)

PreviewSYNLETT Simple Caregiver Pager System User Manual - Wireless Alert Solution
User manual for the SYNLETT Simple Caregiver Pager System (M091B, F100, QF029). Learn setup, features, and usage of this wireless alert system for elderly monitoring and emergency assistance.
PreviewSYNLETT Wireless Chime 30ch User Manual - Setup, Functions, and Troubleshooting
Comprehensive user manual for the SYNLETT Wireless Chime 30ch system (Model Q034G-F007). Covers package contents, safety precautions, product care, specifications, installation, initial system setup, adding/replacing call buttons, call review, memory clearing, system reset, and troubleshooting Q&A. Suitable for clinics, nursing homes, hospitals, and elder care.
PreviewDaytech Wireless Chime/Pager User Manual - INST-EN-CC01-T-20230214
Comprehensive user manual for the Daytech Wireless Chime/Pager (INST-EN-CC01-T-20230214), covering features, specifications, installation, operation, troubleshooting, and maintenance.
PreviewCogeco Hosted Telephony: Guide to Call Functions
A comprehensive guide to the features and functions of Cogeco's hosted telephony service, detailing call management, voicemail, call forwarding, and more.