OONO D-1439

OONO D-1439 8-Channel Rocker Switch Thermal Circuit Breaker Power Distribution Module User Manual

Model: D-1439

1. Introduction

This user manual provides detailed instructions for the installation, operation, and maintenance of the OONO D-1439 8-Channel Rocker Switch Thermal Circuit Breaker Power Distribution Module. This module is designed to provide reliable power distribution and overload protection for various electrical applications, featuring individual thermal circuit breakers for each channel and DIN rail mounting capability.

2. Safety Information

WARNING: Risk of electric shock. Installation and servicing should only be performed by qualified personnel.

  • Always disconnect power before installing, wiring, or servicing the module.
  • Ensure all wiring complies with local and national electrical codes.
  • Do not exceed the specified input voltage or current ratings.
  • Verify proper grounding connections.
  • Avoid operating the module in wet or excessively humid environments.

3. Product Features

  • Input voltage AC 125/250V 50/60Hz. Maximum total input current 40A (one position terminal block maximum current 20A).
  • Maximum output current 10A per channel. Maximum total output current 40A.
  • Equipped with 10Amp rocker switch thermal circuit breaker overload protectors.
  • Manual control for switch output state: RESET or OFF.
  • Built-in red indicator light: on for normal output, off for disconnected output.
  • Terminal Blocks: Pitch 7.62mm/0.3 inch, Wire range 26AWG to 10AWG / 4.0mm square, Strip length 8mm. Screws - M3, steel, Cr3+ Zn plated. Pin header and Cage - Brass.
  • High-quality fireproof nylon material DIN rail mount carrier, compatible with 35mm, 32mm, and 15mm width rails.
  • FR-4 fiberglass dual copper layers PCB for enhanced durability.

4. Components Overview

The OONO D-1439 module consists of the following main components:

  • Input Terminal Block: For connecting the main power supply (L, N, G).
  • Output Terminal Blocks (OUT1-OUT8): For connecting individual loads (L, N).
  • Rocker Switches with Thermal Circuit Breakers: Eight individual switches for controlling and protecting each output channel. Each switch includes a RESET/OFF function and an indicator light.
  • DIN Rail Mount Carrier: Integrated housing for easy installation on standard DIN rails.
Top-down view of the OONO D-1439 8-channel power distribution module

Figure 4.1: Top-down view of the OONO D-1439 8-channel power distribution module, showing input and output terminals, and eight rocker switches with integrated thermal circuit breakers.

Angled perspective view of the OONO D-1439 power distribution module

Figure 4.2: An angled perspective view of the OONO D-1439 module, providing a three-dimensional representation of its layout and components.

Angled view of the OONO D-1439 module with input and output labels

Figure 4.3: Angled view of the OONO D-1439 module, highlighting the input (N, N, L, L) and output (OUT1-OUT8, each with L, N) terminal labels for clear wiring identification.

5. Specifications

ParameterValue
Model NumberD-1439
Input VoltageAC 125/250V 50/60Hz
Max Total Input Current40A (20A per input terminal position)
Max Output Current (per channel)10A
Max Total Output Current40A
Circuit Breaker TypeThermal Rocker Switch, 10 Amps
Terminal Block Pitch7.62mm / 0.3 inch
Wire Range26AWG to 10AWG / 4.0mm²
Strip Length8mm
Mounting TypeDIN Rail Mount (35mm, 32mm, 15mm compatible)
Product Dimensions7.87 x 3.74 x 2.17 inches
Weight11.99 ounces
Dimensional drawing of the OONO D-1439 module

Figure 5.1: Detailed dimensional drawing of the OONO D-1439 module, showing key measurements for installation planning.

6. Setup and Installation

6.1 DIN Rail Mounting

The OONO D-1439 module is designed for easy installation on standard DIN rails (35mm, 32mm, or 15mm width). To mount the module:

  1. Align the module's integrated carrier with the DIN rail.
  2. Press the module firmly onto the rail until it clicks into place.
  3. Ensure the module is securely fastened and does not wobble.
OONO D-1439 module mounted on a DIN rail

Figure 6.1: The OONO D-1439 module securely mounted on a standard DIN rail, demonstrating its integrated mounting mechanism.

Video 6.1: This video demonstrates the physical installation process of the OONO D-1439 module onto a DIN rail, showing how to properly align and secure the unit. The video also briefly showcases the various configurations of the module (e.g., 1-channel, 4-channel, 8-channel versions) and its internal schematic diagram.

6.2 Wiring Instructions

Refer to the schematic diagram and connection method for proper wiring. Ensure all connections are tight and secure.

  1. Input Power Connection: Connect the main AC power supply to the INPUT terminal block. The terminals are labeled 'N' (Neutral) and 'L' (Line). Ensure correct polarity.
  2. Output Load Connection: Connect your loads to the respective OUT1 through OUT8 terminal blocks. Each output has 'L' (Line) and 'N' (Neutral) terminals.
  3. Wire Preparation: Strip approximately 8mm of insulation from the wire ends. Insert the stripped wire into the terminal block and tighten the M3 screw securely.
Schematic diagram of the OONO D-1439 power distribution module

Figure 6.2: Electrical schematic diagram of the OONO D-1439 module, illustrating the internal connections from the main input to each of the eight output channels, including the thermal circuit breakers and indicator lights.

Typical connection use method for the OONO D-1439 module

Figure 6.3: A diagram showing a typical connection method for the OONO D-1439 module, demonstrating how input power is distributed to multiple loads through the individual circuit breakers. It also illustrates how multiple modules can be connected in parallel for expansion.

7. Operation

7.1 Powering On/Off

Each channel is controlled by an individual rocker switch with an integrated thermal circuit breaker.

  • To turn a channel ON, press the rocker switch to the 'RESET' position. The red indicator light on the switch will illuminate, indicating normal output.
  • To turn a channel OFF, press the rocker switch to the 'OFF' position. The red indicator light will turn off.

7.2 Overload Protection

The integrated thermal circuit breakers protect against overcurrent conditions. If an overload occurs on a channel:

  • The circuit breaker for that channel will trip, automatically moving the rocker switch to the 'OFF' position.
  • The red indicator light for that channel will turn off.
  • To reset the breaker after an overload, first identify and resolve the cause of the overload. Then, press the rocker switch back to the 'RESET' position.

8. Maintenance

  • Regularly inspect all wiring connections for tightness and signs of wear or damage.
  • Keep the module clean and free from dust and debris. Use a dry, soft cloth for cleaning.
  • Do not use abrasive cleaners or solvents.
  • Ensure adequate ventilation around the module to prevent overheating.

9. Troubleshooting

ProblemPossible CauseSolution
No power to a channel, switch is OFF.Channel is intentionally off or circuit breaker tripped due to overload.If intentionally off, switch to RESET. If tripped, identify and remove the overload, then reset the switch.
Red indicator light is off when switch is in RESET position.Output disconnected or no power to the module.Check main input power. Verify load connection. If the breaker repeatedly trips, there may be a persistent overload or short circuit.
Module feels excessively hot.Overloaded channels or insufficient ventilation.Reduce load on channels. Ensure proper airflow around the module. Check total current draw against maximum ratings.

10. Warranty and Support

For warranty information or technical support, please contact OONO customer service through the retailer where the product was purchased or visit the official OONO website. Please have your model number (D-1439) and purchase date available when contacting support.

Related Documents - D-1439

Preview OONO F-1040 Automatic Low Voltage Disconnect Module: Features, Specifications, and Installation
Detailed information on the OONO F-1040 Automatic Low Voltage Disconnect Module, including its features, operating voltage, current rating, installation guide, and specifications for protecting batteries from deep discharge.
Preview OONO F-1021 Series 50 Amp Forward & Reverse Relay Module - Technical Specifications
Comprehensive technical specifications, features, wiring diagrams, and dimensions for the OONO F-1021 series 50 Amp Forward & Reverse Relay Module, designed for motor control applications requiring motion reversal.
Preview OONO F-1030 Series DPST 1NO 1NC 8Amp Latching Relay Module | Technical Specifications
Detailed technical specifications, features, and wiring diagrams for the OONO F-1030 series DPST 1NO 1NC 8Amp Latching Relay Module. Covers input control modes, output switch capabilities, voltage versions, and dimensions.
Preview OONO 10 Amp Forward & Reverse Relay Module F-1020 Series: User Guide
Detailed guide for the OONO F-1020 series 10 Amp Forward & Reverse Relay Module, covering features, specifications, wiring diagrams, and dimensions for 5V, 12V, and 24V versions.
Preview OONO F-1081 Series 10 Amp Reversing Relay Module with Limit Switch Support
Technical datasheet for the OONO F-1081 series 10 Amp Reversing Relay Module, featuring support for limit switches and various switch types (momentary, alternate-action). Includes specifications and wiring diagrams for 5V, 12V, and 24V versions.
Preview OONO F-1057 Electric Heating Relay User Manual
Instructions and specifications for the OONO F-1057 On/Off Switching Electric Heating Relay with Built-in 24V Transformer, designed for AC 120V resistive loads controlled by low voltage thermostats.