RENOGY RMS-DCDC-JP

Renogy RMS-DCDC-JP MPPT Charge Controller Monitor Instruction Manual

Model: RMS-DCDC-JP | Brand: RENOGY

1. Introduction

The Renogy RMS-DCDC-JP is a high-precision monitor specifically designed for Renogy MPPT charge controllers. It provides a clean and professional interface for monitoring your charging system. This monitor can be flush-mounted and features a backlit LCD display. With its four intuitive buttons, users can easily view critical system information, including charging parameters and error codes. It offers real-time feedback for two battery systems, ensuring you have the most current status of your power setup.

Renogy RMS-DCDC-JP Monitor with and without backlight

Image: The Renogy RMS-DCDC-JP monitor displaying system information, shown with and without its backlight activated.

2. Key Features

3. Package Contents

Verify that all items listed below are included in your package. If any items are missing or damaged, please contact Renogy customer support.

Contents of the Renogy RMS-DCDC-JP package including monitor, manual, cable, and screws

Image: All components included in the RMS-DCDC-JP product package.

4. Setup and Installation

4.1 Physical Installation

The RMS-DCDC-JP monitor is designed for flush mounting. Ensure you have adequate space behind the mounting surface for the monitor's body and cable connections. Use the provided mounting screws to secure the monitor in place.

Exploded view of the Renogy RMS-DCDC-JP monitor showing internal components and casing

Image: Exploded diagram illustrating the monitor's components, including the PVC board, ABS resin covers, and high-resolution display.

4.2 Electrical Connection

Connect the monitor to your Renogy DCC charge controller using the supplied RJ45 communication cable. Simply plug one end of the RJ45 cable into the monitor's port and the other end into the corresponding port on the DCC charge controller. The monitor will power on automatically once connected.

Renogy RMS-DCDC-JP monitor connected to a DCC charge controller via an RJ45 cable

Image: The RMS-DCDC-JP monitor connected to a Renogy DCC charge controller, showing the RJ45 cable connection.

4.3 Installation Video Guide

Video: A detailed guide on how to install and connect the Renogy RMS-DCDC-JP monitor to your charge controller.

5. Operating Instructions

5.1 Display Overview

The LCD display provides real-time information about your battery and charging system. The displayed items may vary based on your system's configuration.

Diagram of the Renogy RMS-DCDC-JP monitor display showing various icons and parameters

Image: Detailed breakdown of the monitor's display, indicating icons for solar charging, sub-battery, system error, parameter units, alternator, main battery, and charging status.

5.2 Button Functions

The monitor features four buttons for navigation and parameter adjustment.

Renogy RMS-DCDC-JP monitor with labels for its four control buttons

Image: The four control buttons on the monitor: Page Up, Page Down, Previous Page, and Enter/Parameter Setting Key.

5.3 Parameter Adjustment

You can adjust charging current limits for the sub-battery directly from the monitor. This feature allows you to optimize charging based on your battery's specifications and system requirements.

Table showing current limit settings for DCC30S and DCC50S charge controllers via the monitor

Image: Current limit settings for DCC30S and DCC50S models, adjustable via the monitor.

To adjust parameters:

  1. Press the Enter button to access the parameter setting menu.
  2. Use the Up and Down arrow buttons to navigate through the available parameters (e.g., charging voltage, charging current limit).
  3. Press Enter again to select a parameter for adjustment.
  4. Use the Up and Down arrow buttons to change the value.
  5. Press Enter to confirm the new value.
  6. Press the Previous Page button to exit the setting menu.

5.4 Operation Overview Video

Video: An overview of the monitor's display and basic operation, including how to navigate through information screens.

6. Specifications

Table of technical specifications for the Renogy RMS-DCDC-JP monitor

Image: Technical specifications and dimensions of the RMS-DCDC-JP monitor.

ParameterValue
Electrical Specifications5VDC
Supply Current30mA
Self-Consumption<1W
Operating Temperature Range-20°C to 45°C
Voltage Accuracy±0.1V
Current Accuracy±0.1A
Dimensions (L x W x H)70 x 110 x 31.5 mm (2.76 x 4.33 x 1.24 inches)
Weight62g (0.14 lbs)
Output Voltage12 Volts

7. Compatibility

The Renogy RMS-DCDC-JP monitor is compatible with the following Renogy DCC Charge Controllers:

8. Troubleshooting

If you encounter issues with your Renogy RMS-DCDC-JP monitor, please refer to the following common troubleshooting steps:

For persistent issues or advanced troubleshooting, please contact Renogy customer support.

9. Maintenance

The Renogy RMS-DCDC-JP monitor requires minimal maintenance to ensure optimal performance and longevity.

10. Warranty and Support

The Renogy RMS-DCDC-JP monitor comes with a 1-year manufacturer's warranty. This warranty covers defects in materials and workmanship under normal use.

For warranty claims, technical assistance, or any product-related inquiries, please contact Renogy customer support through their official website or the retailer where the product was purchased. Please have your product model number (RMS-DCDC-JP) and proof of purchase ready when contacting support.

10.1 Additional Support Videos

Video: A general overview of Renogy products and their features, which may provide additional context for your system.

Video: Another informational video from Renogy, potentially covering system integration or advanced tips.

Related Documents - RMS-DCDC-JP

Preview Renogy RMS-DCDC Monitoring Screen User Manual for DC-DC Battery Chargers
This manual provides detailed instructions for installing, operating, and troubleshooting the Renogy RMS-DCDC monitoring screen, designed for DC-DC MPPT battery charger series. It covers features, LCD icons, parameter settings, and technical specifications.
Preview Renogy 12V 30A/50A Dual Input DC-DC On-Board Battery Charger with MPPT User Manual
User manual for the Renogy 12V 30A/50A Dual Input DC-DC On-Board Battery Charger with MPPT. Learn about installation, operation, charging logic, safety, and technical specifications for efficient battery management in RVs, boats, and off-grid systems.
Preview Renogy 12V 30A/50A DC-DC On-Board Battery Charger with MPPT User Manual
User manual for the Renogy 12V 30A/50A Dual Input DC-DC On-Board Battery Charger with MPPT. Covers installation, operation, features, safety, technical specifications, and troubleshooting for efficient battery charging in RVs, boats, and off-grid systems.
Preview Renogy RMS-DCDC Monitoring Screen User Manual for DC-DC Battery Chargers
Comprehensive user manual for the Renogy RMS-DCDC monitoring screen, covering installation, operation, features, troubleshooting, and technical specifications for DC-DC MPPT battery chargers. Includes detailed guides on setup, parameter settings, and error code resolution.
Preview Renogy RMS-DCDC Monitoring Screen User Manual
User manual for the Renogy RMS-DCDC Monitoring Screen, providing detailed information on installation, operation, LCD icons, troubleshooting, and technical specifications for DC-DC MPPT battery chargers.
Preview Renogy 12V 30A/50A Dual Input DC-DC On-Board Battery Charger with MPPT User Manual
This user manual provides comprehensive instructions for the Renogy 12V 30A/50A Dual Input DC-DC On-Board Battery Charger with MPPT (models RBC30D1S and RBC50D1S), covering installation, operation, safety precautions, troubleshooting, and technical specifications.